750104 PILZ, 750104 Datasheet - Page 2

no-image

750104

Manufacturer Part Number
750104
Description
PNOZ S4 24 VDC
Manufacturer
PILZ
Datasheet

Specifications of 750104

Coil Voltage Vdc Nom
24V
Contact Current Max
8A
Contact Voltage Ac Nom
240V
Contact Voltage Dc Nom
24V
No. Of Poles
3
Relay Mounting
DIN Rail
External Width
22.5mm
External Depth
120mm
Svhc
No SVHC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
E-STOP relays, safety gate monitors
Up to PL e of EN ISO 13849-1
PNOZ s4
Safety relay for monitoring E-STOP
pushbuttons, safety gates and light
barriers.
Approvals
Block diagram
* only when U
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
B
= 48 – 240 VAC/DC
PNOZ s4
Unit features
Positive-guided relay outputs:
– 3 safety contacts (N/O), instanta-
– 1 auxiliary contact (N/C), instan-
1 semiconductor output
Connection options for:
– E-STOP pushbutton
– Safety gate limit switch
– Reset button
– Light barriers
– PSEN
A connector can be used to con-
nect 1 PNOZsigma contact ex-
pander module
Operating modes can be set via ro-
tary switch
LED indicator for:
– Supply voltage
– Input status, channel 1
– Input status, channel 2
– Switch status, safety contacts
– Reset circuit
– Error
Plug-in connection terminals (either
spring-loaded terminal or screw
terminal)
neous
taneous
Unit description
The safety relay meets the require-
ments of EN 60947-5-1, EN 60204-1
and VDE 0113-1 and may be used in
applications with
Safety features
The relay meets the following safety
requirements:
E-STOP pushbuttons
Safety gates
Light barriers
The circuit is redundant with built-in
self-monitoring.
The safety function remains effec-
tive in the case of a component fail-
ure.
The correct opening and closing of
the safety function relays is tested
automatically in each on-off cycle.
The unit has an electronic fuse.
NSG-D-2-395-2008-11