HC2-HP-DC24V PANASONIC EW, HC2-HP-DC24V Datasheet

Miniature Power Relay

HC2-HP-DC24V

Manufacturer Part Number
HC2-HP-DC24V
Description
Miniature Power Relay
Manufacturer
PANASONIC EW
Datasheet

Specifications of HC2-HP-DC24V

Relay Type
General Purpose
Coil Voltage Vdc Nom
24V
Contact Current Max
7A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
650ohm
Contact Configuration
DPDT
Coil Type
DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
HC
TYPES
HC Relay
A: Available
Notes: 1. HC relays with ground terminals also available.
1
Standard type
Amber sealed
type
HC relay
HC keep
(latching) relay
DC type with
surge absorbing
diode
AC type with
surge absorbing
CR circuit
Keep (Latching) relay
Standard type
Type
2. HC relays with 0.9 mm wide PC board terminals also available.
Single side stable
Single side stable
Single side stable
Single side stable
Single side stable
Bifurcated (Twin)
Bifurcated (Twin)
Bifurcated (Twin)
Bifurcated (Twin)
arrangement
Contact
Amber sealed type
With diode type
arrangement
1 Form C
2 Form C
3 Form C
4 Form C
4 Form C
1 Form C
2 Form C
4 Form C
4 Form C
2 Form C
1 Form C
2 Form C
3 Form C
4 Form C
4 Form C
1 Form C
2 Form C
3 Form C
4 Form C
4 Form C
Contact
(With operating
Without LED
indication)
COMPATIBLE WORLDWIDE
FEATURES
1. Long track record means reliable
quality.
2. Can provide switching across the
range from low to high level power
loads (100 A to 10 A).
3. Rich lineup includes relays with
LED, with diode, and high-capacity
types.
4. UL, CSA approval is standard
Compliance also with Japanese Electrical
Appliance and Material Control Law.
Plug-in terminal type
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
FROM SEQUENCE TO
POWER CIRCUITS
With LED
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
(With operating
Without LED
indication)
PC board terminal type
A
A
A
A
A
A
A
A
A
A
With LED
A
A
A
A
A
A
A
A
A
TYPICAL APPLICATIONS
Suitable for factory automation
equipment and automotive devices
1. Control panels, power supply
equipment, molding equipment,
machine tools, welding equipment,
agricultural equipment, etc.
2. Office equipment, automatic
vending machines,
telecommunications equipment,
disaster prevention equipment,
copiers, measuring devices, medical
equipment, amusement devices, etc.
3. All types of household appliance
PRODUCT TYPES
Top mounting type
HC RELAY
(TM type)
ds_61C04_en_hc: 081008D
A
A
A
A
A
A
A
A
A
Amber sealed type
also available
17 mm higher than
standard type
Remarks

Related parts for HC2-HP-DC24V

HC2-HP-DC24V Summary of contents

Page 1

HC Standard type Amber sealed type Keep (Latching) relay With diode type TYPES HC Relay Contact Contact Type arrangement arrangement 1 Form C 2 Form C Single side stable Standard type 3 Form C 4 Form C Bifurcated (Twin) 4 ...

Page 2

... Minimum switching capability: 100 A 100m V DC (reference value) · LED colors indicate the type of relay: red for AC type and green for DC type. HC keep (Latching) relay HC2K Magnetic latching relay Suitable for nominal operating power saving of operating circuits and for memory circuits Has operating indication (mechanical indicator). ...

Page 3

HC Plug-in type PC board type TM type ORDERING INFORMATION Contact arrangement 1: 1 Form Form Form Form C 4D: Bifurcated contact (twin) Terminal arrangement H: Plug-in type HL: Plug-in with ...

Page 4

... HC2-HP-AC6V-F HC3-HP-AC6V-F HC2-HP-AC12V-F HC3-HP-AC12V-F HC2-HP-AC24V-F HC3-HP-AC24V-F HC2-HP-AC48V-F HC3-HP-AC48V-F HC2-HP-AC100V-F HC3-HP-AC100V-F HC2-HP-AC120V-F HC3-HP-AC120V-F HC2-HP-AC200V-F HC3-HP-AC200V-F HC2-HP-AC240V-F HC3-HP-AC240V-F HC2-HP-DC6V-F HC3-HP-DC6V-F HC2-HP-DC12V-F HC3-HP-DC12V-F HC2-HP-DC24V-F HC3-HP-DC24V-F HC2-HP-DC48V-F HC3-HP-DC48V-F HC2-HP-DC100V-F HC3-HP-DC100V Form C 4 Form C (twin) Part No. Part No. HC4-H-AC6V HC4D-H-AC6V HC4-H-AC12V HC4D-H-AC12V HC4-H-AC24V HC4D-H-AC24V HC4-H-AC48V HC4D-H-AC48V HC4-H-AC100V ...

Page 5

... HC3-HPL-DC48V-F HC2-HPL-DC100V-F HC3-HPL-DC100V-F 2 Form C 3 Form C Part No. Part No. HC2-HTM-AC6V-F HC3-HTM-AC6V-F HC2-HTM-AC12V-F HC3-HTM-AC12V-F HC2-HTM-AC24V-F HC3-HTM-AC24V-F HC2-HTM-AC48V-F HC3-HTM-AC48V-F HC2-HTM-AC100V-F HC3-HTM-AC100V-F HC2-HTM-AC120V-F HC3-HTM-AC120V-F HC2-HTM-AC200V-F HC3-HTM-AC200V-F HC2-HTM-DC6V-F HC3-HTM-DC6V-F HC2-HTM-DC12V-F HC3-HTM-DC12V-F HC2-HTM-DC24V-F HC3-HTM-DC24V-F HC2-HTM-DC48V-F HC3-HTM-DC48V-F HC2-HTM-DC100V-F HC3-HTM-DC100V-F Nominal coil current Drop-out [20%] (at 20C 68F) voltage (at 20 ...

Page 6

Specifications Characteristics Item Arrangement Contact pressure Contact Initial contact resistance, max Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Rating Max. switching current Nominal operating power Min. switching capacity (Reference value)* 1 ...

Page 7

... Coil applied voltage 2.-(1) Switching capacity range (single contact type) 250 100 HC4c HC2c HC1c 1mA 10mA 1A 5A 10A 7A AC current 3.-(2) Coil temperature rise (2 Form C, AC type) Measured portion: Inside the coil Ambient temperature: 30C 86F (See note.) ...

Page 8

DIMENSIONS (mm inch) Interested in CAD data? You can obtain CAD data for all products with a from 1. Plug-in type CAD Data CAD Data CAD Data ds_61C04_en_hc: 081008D your local Panasonic Electric Works representative. 1 Form C type External ...

Page 9

HC 4 Form C and 4-pole bifurcated (twin) types CAD Data 2. PC board type CAD Data PC board pattern 1 Form C 2 Form C 4.1 4.1 .161 .161 10.4 10.4 .409 .409 16.8 16.8 .661 .661 4.45 8-2 ...

Page 10

TM type CAD Data Chassis (Panel) cutout 2-3.6 dia. 2-.142 dia. 37.6 1.480 Tolerance: 0.1 .004 Schematic Same schematic as plug-in type HC relay Be aware that there is no LED indicator with CR circuit and built-in diode types. ...

Page 11

HC Plug-in type PC board type TM type ORDERING INFORMATION Contact arrangement 1: 1 Form Form Form C E: Amber sealed type ED: Amber sealed type bifurcated contact (twin) (Only 4 Form C) Terminal ...

Page 12

... HC2E-L-AC120V-F HC4E-L-AC120V HC2E-L-AC200V-F HC4E-L-AC200V HC2E-L-AC240V-F HC4E-L-AC240V HC2E-L-DC6V-F HC4E-L-DC6V HC2E-L-DC12V-F HC4E-L-DC12V HC2E-L-DC24V-F HC4E-L-DC24V HC2E-L-DC48V-F HC4E-L-DC48V HC2E-L-DC100V-F HC4E-L-DC100V 2 Form C 4 Form C Part No. Part No. HC2E-HP-AC6V-F HC4E-HP-AC6V HC2E-HP-AC12V-F HC4E-HP-AC12V HC2E-HP-AC24V-F HC4E-HP-AC24V HC2E-HP-AC48V-F HC4E-HP-AC48V HC2E-HP-AC100V-F HC4E-HP-AC100V HC2E-HP-AC120V-F HC4E-HP-AC120V HC2E-HP-AC200V-F HC4E-HP-AC200V HC2E-HP-AC240V-F HC4E-HP-AC240V HC2E-HP-DC6V-F HC4E-HP-DC6V HC2E-HP-DC12V-F HC4E-HP-DC12V ...

Page 13

... HC2E-PL-AC12V-F HC2E-PL-AC24V-F HC2E-PL-AC48V-F HC2E-PL-AC100V-F HC2E-PL-AC120V-F HC2E-PL-AC200V-F HC2E-PL-AC240V-F HC2E-PL-DC6V-F HC2E-PL-DC12V-F HC2E-PL-DC24V-F HC2E-PL-DC48V-F HC2E-PL-DC100V-F 2 Form C Part No. HC2E-HTM-AC6V-F HC2E-HTM-AC12V-F HC2E-HTM-AC24V-F HC2E-HTM-AC48V-F HC2E-HTM-AC100V-F HC2E-HTM-AC120V-F HC2E-HTM-AC200V-F HC2E-HTM-AC240V-F HC2E-HTM-DC6V-F HC2E-HTM-DC12V-F HC2E-HTM-DC24V-F HC2E-HTM-DC48V-F HC2E-HTM-DC100V-F Item 1 Form C 1 Form C 5A 250V AC 1,250VA 250VAC 5A 1mA 100mV DC 1 Max. 90C (By resistive method, nominal voltage) Min. 2 ...

Page 14

... REFERENCE DATA 1.-(1) Switching capacity range (single contact type) 250V 100V HC4E 10V HC2E HC1E 10mA 10A AC current 2.-(2) Coil temperature rise (2 Form C AC type) Measured portion: Inside the coil Ambient temperature: 30C 86F 100 100 110 120 Voltage applied to coil ...

Page 15

... Form factors same as for HC relays 4. With operation indicator 5. Can be used in a wide variety of applications. PC board type Part No. HC2K-P-AC6V-F HC2K-P-AC12V-F HC2K-P-AC24V-F HC2K-P-AC48V-F HC2K-P-AC100V-F HC2K-P-DC6V-F HC2K-P-DC12V-F HC2K-P-DC24V-F HC2K-P-DC48V-F HC2K-P-DC100V-F Nominal operating current [10%] Reset voltage Set coil (at 20C 68F) (at 20 ...

Page 16

... Notes:*1This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual load. 2.Other specifications are same as standard types. REFERENCE DATA Coil temperature rise Tested sample: HC2K-DC12V, 2 pcs Measured portion: Inside the coil Ambient temperature: 28C 82.4F 100 ...

Page 17

HC DIMENSIONS (mm inch) Interested in CAD data? You can obtain CAD data for all products with a from Plug-in type (2 Form C) CAD Data PC board type (2 Form C) CAD Data MOUNTING METHOD The mounting method and ...

Page 18

... HC2-DC12V-D-F HC3-DC12V-D-F HC2-DC24V-D-F HC3-DC24V-D-F HC2-DC48V-D-F HC3-DC48V-D-F HC2-DC100V-D-F HC3-DC100V-D-F 2 Form C 3 Form C Part No. Part No. HC2-L-DC6V-D-F HC3-L-DC6V-D-F HC2-L-DC12V-D-F HC3-L-DC12V-D-F HC2-L-DC24V-D-F HC3-L-DC24V-D-F HC2-L-DC48V-D-F HC3-L-DC48V-D-F HC2-L-DC100V-D-F HC3-L-DC100V-D RELAY WITH DIODE We have introduced Cadmium free type products to reduce Environmental Hazardous Substances. (The suffix “F” should be added to the part number. The Suffix “ ...

Page 19

HC RATING 1. Coil data (Common for standard DC coil types) 2. Specifications Characteristics Item Conditions Conditions for operation, transport and storage* Notes: Other specifications are same as standard types. *The upper operation ambient temperature limit is the maximum temperature ...

Page 20

... HC3-AC200V-R-F HC2-AC240V-R-F HC3-AC240V-R-F 2 Form C 3 Form C Part No. Part No. HC2-L-AC100V-R-F HC3-L-AC100V-R-F HC2-L-AC120V-R-F HC3-L-AC120V-R-F HC2-L-AC200V-R-F HC3-L-AC200V-R-F HC2-L-AC240V-R-F HC3-L-AC240V-R-F Item Max. 90C (By resistive method, nominal voltage, rated current at 60C) Ambient temperature: –50C to +60C Humidity 85% R.H. (Not freezing and condensing at low temperature) Information ...

Page 21

HC REFERENCE DATA 1.-(1) AC coil surge voltage waveform (with CR circuit) Tested sample: HC4-AC200V-R 282V 55V 1.5ms 3.2ms To digital AC200V memory DIMENSIONS (Unit: mm inch) Plug-in type Connection accessories Connection accessories (terminal sockets and sockets) are the same ...

Page 22

... UL/CSA approval is standard. SOCKET SELECTOR CHART Type No. of pole Item 2-pole HC2-socket Plug-in 1/2/4-pole HC4-socket (common) HC1-socket for 1-pole PC board HC2-socket for 2-pole PC board PC board HC3-socket for 3-pole PC board 1/2/4-pole HC4-socket for (common) PC board 1/2/4-pole Wrapping HC4-wrapping socket (common) Notes: 1 ...

Page 23

... With a relay mounted (HC2-SS-K) Hold-down clip is packaged with the socket. .008 ds_61C04_en_hc: 081008D Keep relay 4 Form C 2 Form C (twin)     7.06 .278 ...

Page 24

... HC2- PC board type socket (HC2-PS-K) 4.45 4.45 .175 .175 4.45 .175 7.06 .278 1.2 21.2 .835 General tolerance: 0.3 HC4- PC board type socket (HC4-PS-K) 4 ...

Page 25

... Standard wrapping type sockets (HC4-WS-K) 16.76 .660 Note: The external and mounting dimensions are the same for 1-pole (HC1-WS-K), 2-pole (HC2-WS-K), and 3-pole (HC3-WS-K) types. Only the number of terminals varies. Mounting hole diagram 4. Terminal sockets for DIN rail assembly HC2-Slim type terminal sockets for DIN rail assembly (HC2-SFD-S) ...

Page 26

... HC2-high terminal socket for DIN rail assembly (HC2-SFD-K) HC3-high terminal socket for DIN rail assembly (HC3-SFD-K) HC4-high terminal socket for DIN rail assembly (HC4-SFD-K) Mounting hole diagram HC2-Slim type HC2, HC3 and HC4 10 9 .394 .354 26 15±0.2 15±0.2 1.024 .591±.008 .591± ...

Page 27

... HC 5. Ordinary terminal sockets HC2-terminal socket (HC2-SF-K for HC2) HC3-high terminal socket (HC3-HSF-K) suitable for both HC2 and HC3 HC4-high terminal socket (HC4-HSF-K) suitable for and 4 Mounting hole diagram HC2-SF-K 2-M3.5 screw hole (or 4.2±0.1 dia. hole) 2-M.138 screw hole (or .165± ...

Related keywords