HC2-HP-DC24V PANASONIC EW, HC2-HP-DC24V Datasheet - Page 16

Miniature Power Relay

HC2-HP-DC24V

Manufacturer Part Number
HC2-HP-DC24V
Description
Miniature Power Relay
Manufacturer
PANASONIC EW
Datasheet

Specifications of HC2-HP-DC24V

Relay Type
General Purpose
Coil Voltage Vdc Nom
24V
Contact Current Max
7A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
650ohm
Contact Configuration
DPDT
Coil Type
DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2) DC coils
Notes: 1. The allowable coil resistance range is 10% when within 1,000 and 15% when. 1,000 or higher.
2. Specifications
Notes:*1This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual
REFERENCE DATA
Coil temperature rise
Tested sample: HC2K-DC12V, 2 pcs
Measured portion: Inside the coil
Ambient temperature: 28C
ds_61C04_en_hc: 081008D
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
arrangement
Characteristics
2 Form C
load.
Contact
2.Other specifications are same as standard types.
2. The maximum allowable voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
100
90
80
70
60
50
40
30
20
10
(This value differs depending on the ambient temperature. Please contact us for details.)
0
80
100V DC
Nominal
12V DC
24V DC
48V DC
voltage
6V DC
Contact pressure
Initial contact resistance, max
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching current
Nominal operating power
Min. switching capacity (Reference value)*
Breakdown voltage (Initial)
Temperature rise
Set time/Reset time (at 20C 68F)
Shock resistance
Mechanical
Electrical
Ambient temperature
coil
90
Coil applied voltage, %V
82.4F
100
80%V or less of
nominal voltage
(at 20C 68F)
Set voltage
(Initial)
110
120
3A
0A
80%V or less of
nominal voltage
Item
(at 20C 68F)
Reset voltage
Between contact and coil
Functional
(Initial)
1
Nominal operating current
51.1mA
25.3mA
15.6mA
[10%] (at 20C 68F)
Set coil
207mA
100mA
Reset coil
Approx. 0.098N{10gf}
Max. 50 m (By voltage drop 6 V DC 1A)
3A 250V AC
750VA
3A
Set coil: 1.20VA to 1.33VA; Reset coil: 0.51VA to 0.88VA
100A 100mV DC
1,500 Vrms for 1min. (initial)
Set coil: Max. 80C; Reset coil: Max. 50C (at nominal voltage)
Approx. 20ms/30ms (at nominal voltage)
Min. 98m/s
Min. 10
Min. 210
–40C to +50C
52.2mA
25.5mA
13.7mA
107mA
5.8mA
7
(at 180 cpm)
5
2
rated load (at 20 cpm)
(Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
[10%] (at 20C 68F)
Set coil
1,897
6,410
120
470
–40F to +122F
29
Coil resistance
Reset coil
17,241
3,504
230
941
56
(Not freezing and condensing at low temperature)
Specifications
Nominal operating power
Set coil
1.24W
1.20W
1.23W
1.21W
1.56W
Reset coil
0.64W
0.63W
0.61W
0.66W
0.58W
(at 50C 122F)
nominal voltage
Max. allowable
110%V of
voltage
HC
16

Related parts for HC2-HP-DC24V