XS2F-A421-C90-A Omron, XS2F-A421-C90-A Datasheet

no-image

XS2F-A421-C90-A

Manufacturer Part Number
XS2F-A421-C90-A
Description
Sensor I/O Connector
Manufacturer
Omron
Datasheet
Many Models Including Roller Lever
Switches are Only 16-mm Thick with
Connector
• New center roller lever models that enable ganged mounting of up to
• Cable connectors for easy Switch replacement.
• Triple-seal construction to provide IEC IP67 degree of protection.
• Operation indicators available for easy monitoring (standard indicator
• Approved by UL and CSA.
Model Number Structure
Model Number Legend
D4CC-@0@@
(1) Rated Current
1 : 1 A at 125 VAC
2 : 1 A at 125 VAC (with LED indicator)
3 : 1 A at 30 VDC
4 : 1 A at 30 VDC (with LED indicator)
Ordering Information
Switches
Limit Switches
Note: 1. Ask your OMRON representative for Information on approved models.
Actuator
Pin
plunger
Roller
plunger
Crossroller
plunger
High-sensitivity
roller lever
Sealed pin
plunger
Sealed roller
plunger
Sealed crossroller
plunger
Plastic
rod
Center
roller lever
6 Switches.
is lit when Switch is not operating).
(Ask your OMRON representative for Information on approved
models.)
Miniature Limit Switch
D4CC
2. The meaning of suffix codes in the D4CC model numbers is different from that in the D4C model numbers.
3. Refer to the following table for cable plugs.
(1)
(2)
LED indicator
Ratings
(Not all combinations are possible. Ask your OMRON representative for details.)
Without indicator
D4CC-1001
D4CC-1002
D4CC-1003
D4CC-1024
D4CC-1031
D4CC-1032
D4CC-1033
D4CC-1050
D4CC-1060
Model
(2) Actuator
01 : Pin plunger
02 : Roller plunger
03 : Crossroller plunger
24 : Roller lever
31 : Sealed pin plunger
32 : Sealed roller plunger
33 : Sealed crossroller plunger
50 : Plastic rod
60 : Center roller lever
1 A at 125 VAC
With indicator
D4CC-2001
D4CC-2002
D4CC-2003
D4CC-2024
D4CC-2031
D4CC-2032
D4CC-2050
D4CC-2060
Model
---
Without indicator
D4CC-3001
D4CC-3002
D4CC-3003
D4CC-3024
D4CC-3031
D4CC-3032
D4CC-3033
D4CC-3050
D4CC-3060
Be sure to read Safety Precautions on page 7 to 8
and Safety Precautions for All Limit Switches.
Model
1 A at 30 VDC
CSM_D4CC_DS_E_3_1
With indicator
D4CC-4001
D4CC-4002
D4CC-4003
D4CC-4024
D4CC-4031
D4CC-4032
D4CC-4033
D4CC-4050
D4CC-4060
Model
1

Related parts for XS2F-A421-C90-A

XS2F-A421-C90-A Summary of contents

Page 1

... D4CC-1050 rod Center D4CC-1060 roller lever Note: 1. Ask your OMRON representative for Information on approved models. 2. The meaning of suffix codes in the D4CC model numbers is different from that in the D4C model numbers. 3. Refer to the following table for cable plugs. (2) Actuator 01 : Pin plunger 02 : Roller plunger ...

Page 2

... D150 Current (A) Rated Carry voltage current Make Break 120 VAC 1.0 A 3.6 0.6 Type For AC Model Cable length 1 m XS2F-A421-C90 XS2F-A421-D90 XS2F-A421-G90 XS2F-A421-J90-A Example of Replacement Note: The position of the dog remains unchanged. Plate D4C-P001 Dog D4C-P002 D4C-P020 Characteristics File No. Degree of protection ...

Page 3

... Note: Colors in parentheses are the previous wire colors. Wire colors have been changed accompanying changes in standards. For AC Plug Pin No. Roller Center lever Spacer prevents the Switch from biting cut chips. O-ring (NBR) Built-in switch DC Switches (D4CC-30@@, 40@@) Without Operation Indicator Pin No.1 COM E With Operation Indicator (Lit when Not Actuated) *1 Pin No.1 COM E For DC Cable Pin No. ...

Page 4

... Dimensions and Operating Characteristics Switches Limit Switches The @ in each model number is replaced with the code expressing the rated load of the model. Refer to Model Number Legend. Pin Plunger 10 dia. D4CC-@001 stainless steel plunger 40 max. PT ± 25 0.1 OP 62.2 max. 57 max. 10.5 (2) Indicator 34 M12 × ...

Page 5

... D4CC-@032 D4CC-@033 17.65 N 17.65 N 4.41 N 4.41 N 1 0.2 mm 0.2 mm 34.3±1 mm 34.3±1 mm (5) mm (5) mm For AC Model XS2F-A421-C90-A XS2F-A421-D90-A XS2F-A421-G90-A XS2F-A421-J90-A 6 dia. 40.7 L D4CC Nylon rod 40 max. ± 3.2 dia. 6.6 dia. Rubber seal ± 104 2 ...

Page 6

... Special Mounting Plates (Limit Switches are not attached to the Plates.) D4C-P001 (For D4CC-@001) 34 (OP of WLD) D4C-P002 (For D4CC-@002) 44 (OP of WLD2) D4C-P020 (For D4CC-@024) 9.2 75 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Remarks There is no difference in mounting pitch between the Mounting Plate and the WL ...

Page 7

... Always appraise performance under actual application conditions and set suitable maintenance and replacement periods. • Install Switches where they will not be directly subject to cutting chips, dust, or dirt. The Actuator and Switch must also be protected from the accumulation of cutting chips or sludge. ...

Page 8

Plug Tightening • Connect the plug connector (B) to the connector threads (C) of the D4CC. Then firmly turn the plug connector by hand so that the connector threaded portion (C) will be completely covered by the plug connector (B) ...

Page 9

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...