XS2F-A421-DB0-A Omron, XS2F-A421-DB0-A Datasheet

no-image

XS2F-A421-DB0-A

Manufacturer Part Number
XS2F-A421-DB0-A
Description
Sensor I/O Connector
Manufacturer
Omron
Datasheet
Limit Switch Connectors
Connectors (SC Series)
Cabtire cables and flexible tubes with various diameters are used to
connect machine tools and controllers with Limit Switches. To ensure
the watertightness of the edges of the conduits, use an SC Connector
that is suitable for the external diameter of cable and model of Limit
Switch.
Ordering Information
Connector for Cabtire Cable
Note: 1. Use SC-21 to SC-25 together with the rubber ring and conduit washer for the SC-P2.
Simple Connector
Note: The casings for SC-P2, -P3 and -6 are made of resin. If more sealing capability is required, use one of SC-1M to SC-5M, which have metal casings.
JIS B 0202 G½
½-14NPT
JIS B 0202 G½
Pg13.5
JIS B 0202 G½
Conduit
Conduit
2. It is necessary to use sealing tape with SC Connectors. SC-1M to SC-5M, however, are provided with an O-ring (NBR) and therefore sealing tape is not
Models marked with an asterisk (*) however, can only be used with resin connectors.
necessary to ensure a proper seal.
Cabtire cable (general-
purpose)
Cabtire cable (anti-
corrosive)
Cabtire cable
Cabtire cable
Applicable cable
Applicable cable
Inner diameter (D)
7 mm
9 mm
12.5 mm
14 mm
11 mm
7 mm
9 mm
12.5 mm
14 mm
11 mm
7 mm
9 mm
12.5 mm
14 mm
11 mm
Inner diameter (D)
10.6 mm
9.6 mm
9 mm
of seal rubber
of seal rubber
5.5 mm
7.5 mm
11 mm
12 mm
9 mm
5.5 mm
7.5 mm
11 mm
12 mm
9 mm
5.5 mm
7.5 mm
11 mm
12 mm
9 mm
8.5 mm
7.5 mm
7.5 mm
External diameter of cable
External diameter of cable
Min.
Min.
7.5 mm
9.5 mm
13 mm
14 mm
11 mm
7.5 mm
9.5 mm
13 mm
14 mm
11 mm
7.5 mm
9.5 mm
13 mm
14 mm
11 mm
10.5 mm
9.5 mm
9 mm
Max.
Max.
SC-1M
SC-2M
SC-3M
SC-4M
SC-5M
SC-21
SC-22
SC-23
SC-24
SC-25
SC-1PT
SC-2PT
SC-3PT
SC-4PT
SC-5PT
SC-P2
SC-P3
SC-6
Model
Model
CSM_LimitSwitch_Connector_DS_E_2_1
WL, D4A-@N, D4B-@N, ZE,
ZV, ZV2, XE, XV, XV2
D4A-@N
WL, D4A-@N, D4B-@N, ZE,
ZV, ZV2, XE, XV, XV2
WL@-G, D4B-@N
WL, D4A-@N, D4N *,
D4N-@R *, D4B-@N, ZE, ZV,
ZV2, XE, XV, XV2
Applicable model
Applicable model
1

Related parts for XS2F-A421-DB0-A

XS2F-A421-DB0-A Summary of contents

Page 1

... Limit Switch Connectors Connectors (SC Series) Cabtire cables and flexible tubes with various diameters are used to connect machine tools and controllers with Limit Switches. To ensure the watertightness of the edges of the conduits, use an SC Connector that is suitable for the external diameter of cable and model of Limit Switch ...

Page 2

Dimensions and Structure Connectors for Cabtire Cable SC-P2 accessories and sealing tape must be used together with models without an O-ring in order to prevent ingress of oil or water. Follow the instructions given under Conduits on page 4. Metal ...

Page 3

... DC 4 SC-4F4D Connecting Cable + Size of Size of crimp Applicable conduit terminal model JIS B 0202 M4 WL G½ Model XS2F-A421-DB0-A XS2F-A421-GB0-A XS2F-A421-D90-A XS2F-A421-G90-A XS2F-D421-DD0 XS2F-D421-GD0 XS2F-D421-D80-A XS2F-D421-G80-A Sensor I/O Connector XS2F-A421-@B0-A ↑ D: 2-m cord G: 5-m cord XS2F-A421-@90-A ↑ D: 2-m cord G: 5-m cord XS2F-D421-@D0 ↑ ...

Page 4

Dimensions SC-2F 27 SC-2FAD 27 SC-4F4AD 27 SC-4F4D 27 Note: 1. Each dimension has a tolerance of ±0.4 mm unless otherwise specified. 2. Figures in parentheses are connector pin numbers. Safety Precautions Precautions for Correct Use Conduits Connector for Cabtire ...

Page 5

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...