Specifications of W9751G6JB-3

Organization
32Mx16
Density
512Mb
Address Bus
14b
Access Time (max)
450ps
Maximum Clock Rate
667MHz
Operating Supply Voltage (typ)
1.8V
Package Type
WBGA
Operating Temp Range
0C to 85C
Operating Supply Voltage (max)
1.9V
Operating Supply Voltage (min)
1.7V
Supply Current
150mA
Pin Count
84
Mounting
Surface Mount
Operating Temperature Classification
Commercial
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W9751G6JB-3
Manufacturer:
Winbond
Quantity:
2 596
Part Number:
W9751G6JB-3
Manufacturer:
WINBOND
Quantity:
1 000
Part Number:
W9751G6JB-3
Manufacturer:
WINBOND
Quantity:
8 000
Part Number:
W9751G6JB-3
Manufacturer:
WINBOND/华邦
Quantity:
20 000
7.3
7.3.1
( CS = "L", RAS = "L", CAS = "H", WE = "H", BA0, BA1 = Bank, A0 to A12 be row address)
The Bank Activate command must be applied before any Read or Write operation can be executed.
Immediately after the bank active command, the DDR2 SDRAM can accept a read or write command
on the following clock cycle. If a Read/Write command is issued to a bank that has not satisfied the
t
Read/Write command is internally issued to the device. The additive latency value must be chosen to
assure t
been activated it must be precharged before another Bank Activate command can be applied to the
same bank. The bank active and precharge times are defined as t
minimum time interval between successive Bank Activate commands to the same bank is determined
by the RAS cycle time of the device (t
commands is t
7.3.2
( CS = "L", RAS = "H", CAS = "L", WE = "H", BA0, BA1 = Bank, A10 = "L", A0 to A9 = Column
Address)
The READ command is used to initiate a burst read access to an active row. The value on BA0, BA1
inputs selects the bank, and the A0 to A9 address inputs determine the starting column address. The
address input A10 determines whether or not Auto-precharge is used. If Auto-precharge is selected,
the row being accessed will be precharged at the end of the READ burst; if Auto-precharge is not
selected, the row will remain open for subsequent accesses.
RCDmin
Figure 12 – Bank activate command cycle: t
Command Function
Bank Activate Command
Read Command
RCDmin
specification, then additive latency must be programmed into the device to delay when the
RRD
is satisfied. Additive latencies of 0, 1, 2, 3, 4, 5 and 6 are supported. Once a bank has
.
RC
). The minimum time interval between Bank Activate
- 20 -
RCD
= 3, AL = 2, t
Publication Release Date: Jun. 18, 2010
RAS
RP
= 3, t
and t
RRD
W9751G6JB
RP
, respectively. The
= 2, t
CCD
Revision A03
= 2