5962-8984103LA E2V, 5962-8984103LA Datasheet - Page 3

no-image

5962-8984103LA

Manufacturer Part Number
5962-8984103LA
Description
Manufacturer
E2V
Datasheet

Specifications of 5962-8984103LA

Lead Free Status / RoHS Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
5962-8984103LA
Manufacturer:
DATEL
Quantity:
200
Part Number:
5962-8984103LA
Manufacturer:
INTERSIL
Quantity:
331
Part Number:
5962-8984103LA
Manufacturer:
CYP
Quantity:
426
DEFENSE SUPPLY CENTER COLUMBUS
DSCC FORM 2234
APR 97
1.4 Recommended operating conditions.
a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those
cited in the solicitation or contract.
Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and
regulations unless a specific exemption has been obtained.
non-JAN class level B devices and as specified herein. Product built to this drawing that is produced by a Qualified
Manufacturer Listing (QML) certified and qualified manufacturer or a manufacturer who has been granted transitional
certification to MIL-PRF-38535 may be processed as QML product in accordance with the manufacturers approved
program plan and qualifying activity approval in accordance with MIL-PRF-38535. This QML flow as documented in the
Quality Management (QM) plan may make modifications to the requirements herein. These modifications shall not affect
form, fit, or function of the device. These modifications shall not affect the PIN as described herein. A "Q" or "QML"
certification mark in accordance with MIL-PRF-38535 is required to identify when the QML flow option is used.
drawing.
COLUMBUS, OHIO 43218-3990
2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form
(Copies of these documents are available online at
3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535, appendix A for
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as
3.2.1. Terminal connections. The terminal connections shall be as specified on figure 1.
3.2.2 Truth table. The truth table shall be as specified on figure 2.
3.2.2.1 Unprogrammed devices. The truth table for unprogrammed devices shall be as specified on figure 2.
3.2.2.2 Programmed devices. The truth table for programmed devices shall be as specified by an attached altered item
3.2.3 Case outlines The case outlines shall be in accordance with 1.2.2 herein.
2. APPLICABLE DOCUMENTS
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein,
3. REQUIREMENTS
MICROCIRCUIT DRAWING
DEPARTMENT OF DEFENSE SPECIFICATION
DEPARTMENT OF DEFENSE STANDARDS
DEPARTMENT OF DEFENSE HANDBOOKS
Supply voltage range (V
High level input voltage (V
Low level input voltage (V
High level output current (I
Low level output current (I
Case operating temperature range (T
MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for.
MIL-STD-883
MIL-STD-1835 -
MIL-HDBK-103 -
MIL-HDBK-780 -
specified in MIL-PRF-38535, appendix A and herein.
STANDARD
-
Test Method Standard Microcircuits.
Interface Standard Electronic Component Case Outlines.
List of Standard Microcircuit Drawings.
Standard Microcircuit Drawings.
CC
IL
OL
)----------------------------------------
IH
OH
) --------------------------------------
)--------------------------------------
) -------------------------------------
) ------------------------------------
C
) -----------------------
http://assist.daps.dla.mil/quicksearch/
SIZE
A
4.5 V dc to 5.5 V dc
2.0 V dc to V
V
-2.0 mA maximum
12 mA maximum
-55°C to +125°C
REVISION LEVEL
SS
-0.5 V dc to +0.8 V dc
L
CC
+1.0 V dc
or from the Standardization
SHEET
5962-89841
3

Related parts for 5962-8984103LA