OKL-T/1-W12P-C Murata Power Solutions Inc, OKL-T/1-W12P-C Datasheet - Page 12

DC-DC CONVERTER, 5.5V, 5W

OKL-T/1-W12P-C

Manufacturer Part Number
OKL-T/1-W12P-C
Description
DC-DC CONVERTER, 5.5V, 5W
Manufacturer
Murata Power Solutions Inc
Datasheet

Specifications of OKL-T/1-W12P-C

Dc / Dc Converter O/p Type
Programmable
No. Of Outputs
1
Input Voltage
2.9VDC To 14VDC
Power Rating
5W
Output Voltage
5.5V
Output Current
1A
Approval Bodies
EN, IEC, UL
Supply Voltage
12V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
OKL-T/1-W12 PERFORMANCE DATA AND OSCILLOGRAMS
Step Load Transient Response (Vin=14V, Vout=2.5V, Cload=0, Iout=0.5A to 1A,
100
90
80
70
60
50
40
30
20
10
0
0
Ta=+25°C.) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 0.5A/div.
Effi ciency vs. Line Voltage and Load Current @Ta = +25 °C
0.1
0.2
0.3
(Vout = 1.8V)
Load Curre nt (Amps)
0.4
V
V
V
0.5
IN
IN
IN
= 2.9V
= 12V
= 14V
100
90
80
70
60
50
40
30
20
10
0
0.6
0
Effi ciency vs. Line Voltage and Load Current @Ta = +25 °C
0.7
0.1
0.8
0.2
www.murata-ps.com
0.9
0.3
(Vout = 1.5V)
Load C urre nt (Amps)
1
0.4
V
V
V
0.5
IN
IN
IN
= 2.9V
= 12V
= 14V
1.20
1.10
1.00
0.90
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
Step Load Transient Response (Vin=14V, Vout=2.5V, Cload=0, Iout=1A to 0.5A,
30
0.6
Ta=+25°C.) Trace 2=Vout, 100 mV/div. Trace 4=Iout, 0.5A/div.
Programmable Output 1-Amp iLGA SMT PoLs
35
0.7
Maximum Current Temperature Derating at Sea Level
40
0.8
09 May 2011
45
0.9
OKL-T/1-W12 Series
(Vin = 4V, Vout = 1.8V)
50
Ambient Temperature (ºC)
1
65 LFM
MDC_OKL-T/1-W12 Series.A04 Page 12 of 18
55
60
email: sales@murata-ps.com
65
70
75
80
85