TLE6244XXT Infineon Technologies, TLE6244XXT Datasheet - Page 34

no-image

TLE6244XXT

Manufacturer Part Number
TLE6244XXT
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of TLE6244XXT

Switch Type
Low Side
Power Switch Family
TLE 6244X
Input Voltage
-0.3 to 36V
Power Switch On Resistance
620mOhm
Output Current
1.1A
Number Of Outputs
18
Mounting
Surface Mount
Package Type
MQFP
Operating Temperature (min)
-40C
Operating Temperature (max)
150C
Operating Temperature Classification
Automotive
Pin Count
64
Lead Free Status / RoHS Status
Compliant
Final Data Sheet
1.10 VDD-Monitoring
Overview:
Description in Detail:
Description of the Register:
STATCON_REG
Bit 7
Bit 6
Bit 5
Bit 2
Bit 1
The VDD-monitoring generates a „low“ signal at the bidirectional pin ABE if the 5V supply volt-
age at pin VDD is out of the permissible range of 4.5V...5.5V. On ABE = low the power stages of
TLE6244X are switched off. Exception: OUT8 is not switched off in case of parallel control via
IN8 by the VDD monitoring undervoltage threshold, but by a threshold of 3.5V at VDD.
On shorting pin ABE to V DD or UBATT ( 36V), the power stages will be switched off in case of
undervoltage or overvoltage at pin VDD in spite of ABE = high.
The behavior of the ABE level on the return of VDD out of the undervoltage range into the cor-
rect range is not configurable. At the transition from undervoltage to normal voltage the signal
at pin ABE goes high after a filtering time is expired. The behavior of the ABE level on the
return of VDD out of the overvoltage range into the correct range is configurable in
STATCON_REG, Bit5. At the transition from overvoltage to normal voltage the signal at pin ABE
goes high either after a filtering time (OV not latched) or after a SPI writing instruction (OV
latched, state after reset).
On undervoltage condition the signal at pin ABE goes high after a filtering time is expired. On
overvoltage condition pin ABE goes high either after a filtering time or after a SPI writing instruc-
tion. Before this SPI instruction is sent to TLE6244X appropriate tests can be carried out by the
controller.
If the voltage at pin VDD is below the lower limit or is resp. was above the upper limit, this can
be read out by the SPI instruction RD_STATCON.
VDD-monitoring has no influence on SCON_REGx, MUX_REGx, DIA_REGx, CONFIG and
INP_REGx.
If output stages are switched off by the internal over-/undervoltage detection or by externally
applying a low signal at the ABE pin, no failure storage (DIAREG1...5) may occur.
Access by controller: read/write
State of reset: 1
Access by controller: read/write
State of reset: 1
State of reset: 1
Access by controller: read only
Access by controller: read only
1: Normal operation
0: Test of VDD threshold
1: Testing the lower threshold (if bit 7 = 0)
0: Testing the upper threshold (if bit 7 = 0)
1: ABE latched after overvoltage
0: ABE deactivated immediately after the disappearance of the overvoltage
Access by controller: read/write
1: no undervoltage at pin VDD
0: undervoltage at pin VDD
Reading out the level at pin ABE
34
TLE 6244X
V4.2, 2003-08-29

Related parts for TLE6244XXT