Specifications of CUB7CVS0

Count Rate
10kHz
Number Of Digits/alpha
8
Input Type
*
Voltage - Supply
None Required (Battery Included)
Display Type
LCD Non-Backlit
Output Type
*
No. Of Digits / Alpha
8
Digit Height
8.9mm
Counting Speed
10kHz
Operating Temperature Range
0°C To +50°C
Display Mode
LCD Positive Reflective
Backlighting Color
Red
Panel Cutout Height
0.874"
Backlight Power
9-28VDC
Counter Supply Voltage
9-28VDC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
RLC138

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CUB7CVS0
Manufacturer:
Red Lion Controls
Quantity:
135
appropriately prior to wiring.
or both.
the low voltage input units or the single DIP switch on the high voltage input
units. (See 2.0 Setting the DIP Switches for switch location)
Note: Placing the KEY DISABLE/ENABLE DIP switch in the OFF position, disables all front panel keys.
keypad with the DIP switch and press the SEL key. The currently programmed
time range will be displayed (example 2222222.2 = time range 2). To change the
range, press the RST key. The ranges will cycle from 0-8 and back to 0. To enter
your time range, press the SEL key and the unit will retain the current time range
and return back to normal.
2.0 S
3.0 P
4.0 R
Low voltage input units have 3 DIP switches that must be positioned
The display may be reset to zero via the front RST key, the remote reset input
The front RST key must be enabled for front panel reset. DIP switch # 3 on
The CUB7 Timer has 9 time ranges. To change ranges, enable the front
ON
SEL
1 2 3
ETTING THE
ROGRAMMING
ESETTING
85374216
Low Voltage Input Unit
Bottom of Unit
Rear of Unit
T
HE
DIP S
T
RST
D
HE
ISPLAY
WITCHES
T
4
IME
keypad.
between the reset input (blue wire) and the common (black wire). When the
optional terminal blocks are used, see 5.0 Wiring The Meter, for the appropriate
reset input terminal and the common terminal.
DISPLAY DURING
PROGRAMMING
High voltage input units have 1 DIP switch to enable or disable the front bezel
The remote reset is activated via an external momentary contact closure
333333333
555555555
00000.000
2222222.2
4444444.4
666666.66
7777777.7
88888888
111111.11
ON
1
R
ANGE
TIMER RANGE
0.001 SEC
0.01 SEC
0.1 SEC
1 SEC
0.1 MIN
1 MIN
0.01 HR
0.1 HR
1 HR
High Voltage Input Unit
Bottom of Unit
Rear of Unit