H7HP-A Omron, H7HP-A Datasheet

COUNT TIME/TOTAL 6DIGT 100-240V

H7HP-A

Manufacturer Part Number
H7HP-A
Description
COUNT TIME/TOTAL 6DIGT 100-240V
Manufacturer
Omron
Type
Count/Time Totalizersr
Datasheets

Specifications of H7HP-A

Count Rate
*
Number Of Digits/alpha
*
Input Type
*
Voltage - Supply
*
Display Type
*
Output Type
*
Voltage Rating
100 V to 240 V
Mounting
Panel
Counting Method
Up, Down or Accumulative
Size
65.8 mm L x 67.7 mm W x 35.7 mm H
Features
NEMA 4 protection using Y92S-32 rubber gasket supplied with unit
No. Of Digits / Alpha
6
Digit Height
15mm
Power Consumption
6.5VA
Counting Speed
5kHz
Operating Temperature Range
-10°C To +55°C
Character Size
15mm
Height
24mm
Mounting Type
Panel
Color
Gray
Connector Type
Screw Terminals
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H7HPA
Model Number Structure
■ Model Number Legend
1. Classification
2. Digits
Ordering Information
■ List of Models
DIN 72 x 36-mm Total Counter/Time Counter
with Easy-to-read Displays and Water and
Oil Resistance Equivalent to IP66
• Large, easy-to-read displays: 15-mm-high characters for 6-digit
• High-visibility, negative transmissive LCD display with built-in
• IP66 with oil resistance and NEMA4 are achieved by unifying
• Compact (66 mm) body.
• Switch 6-digit models between total counter and time counter
• Just change a switch setting for either an NPN or PNP input.
• Supports both external resetting and manual resetting.
• Finger-protection terminal block cover prevents electrical shock
• Safety standards: UL, CSA, EMC (EN 61326), CE Marking.
H7HP-@@@@
100 to 240 VAC
12 to 24 VDC
models; 12-mm-high characters for 8-digit models.
red LED backlight at low power consumption.
the front with the casing case and using oil-resistant materials
and parts.
operation.
and conforms to VDE0106, Part 100.
Total Counter/Time Counter (DIN 72 x 36)
H7HP
A:
C:
None: 6 digits
8:
Supply voltage
Total counter/time counter
Total counter
8 digits
1 2 3 4
H7HP-A
H7HP-AD
Light gray
6-digit total counter/time counter
H7HP-AB
H7HP-ADB
Black
3. Supply Voltage
4. Case Color
None: 100 to 240 VAC
D:
None: Light gray (Munsell 5Y7/1)
B:
12 to 24 VDC
Black
H7HP-C8
H7HP-C8D
Light gray
8-digit total counter
H7HP-C8B
H7HP-C8DB
CSM_H7HP_DS_E_3_1
Black
1

H7HP-A Summary of contents

Page 1

... Light gray 100 to 240 VAC H7HP VDC H7HP-AD 3. Supply Voltage None: 100 to 240 VAC VDC 4. Case Color None: Light gray (Munsell 5Y7/1) B: Black Black Light gray H7HP-AB H7HP-C8 H7HP-ADB H7HP-C8D CSM_H7HP_DS_E_3_1 8-digit total counter Black H7HP-C8B H7HP-C8DB 1 ...

Page 2

... Only a non-voltage input (NPN transistor) is possible for the key protection input. The key protection input will be a non-voltage input even if the NPN/PNP input mode is set to PNP. Key protection is used to prohibit operating the Reset Key. The reset input terminals will still be functional. H7HP-AD --- VDC ...

Page 3

... EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3) EN61000-4- power-line (level 3 I/O signal-line (level 4) EN61000-4- line to lines (power and output lines) (level 2 line to ground (power and output lines) (level 3) H7HP 3 ...

Page 4

... Count 2 Reset protection input or input or input input start input gate input NPN mode Operation ■ DIP Switch Settings Switches are all set to OFF before shipping. H7HP-A@ Pin no. Item OFF 1 Function Total counter 2 Counting speed 30 Hz (note) Time range (note) 99999 Input mode (note) NPN ...

Page 5

... Resets the count value, but will not operate while the keys are protected. 2. Key Protection Indicator Lit while the keys are protected (Reset Key is disabled.). 3. DIP Switch Use to change a setting. Refer to DIP Switch Settings for details. display (The figure shows the DIP switch label stuck to the rear of the case.) 3 H7HP 5 ...

Page 6

... Dimensions Note: All units are in millimeters unless otherwise indicated. H7HP-A H7HP-C8 Panel Cutouts Panel cutouts are as shown below (according to DIN43700). With Flush Mounting Bracket M3.5 terminal screw Terminal cover (provided) Note: 1. The mounting panel thickness should mm. 2. Water resistance will be lost if Counters are mounted side-by-side ...

Page 7

... Connections (Common) ■ Input Connections Note: The following is common for all H7GP/H7HP models. No-voltage Input (NPN Input Mode) Reset, Count 1, Count 2, Start, and Gate Inputs Open Collector Output Voltage Output H7GP/H7HP 12 VDC ( VDC) Sensor Sensor Reset input Count 1 input Count 2 input ...

Page 8

... Use the H7GP/H7HP within the specified ratings for operating temperature and humidity. • Do not operate the H7GP/H7HP in locations subject to sudden or extreme changes in temperature, or locations where high humidity may result in condensation. • Do not use the H7GP/H7HP in locations subject to vibrations or shock ...

Page 9

... Press RST Key or turn power OFF and then ON e2 Memory Labels Unit labels are included with the H7GP/H7HP and DIP switch labels are included with the H7HP. Attach these labels as shown in the following illustrations. Unit Labels H7GP H7HP DIP Switch Labels H7HP ALL DIMENSIONS SHOWN ARE IN MILLIMETERS ...

Page 10

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...