H7HP-A Omron, H7HP-A Datasheet

COUNT TIME/TOTAL 6DIGT 100-240V

H7HP-A

Manufacturer Part Number
H7HP-A
Description
COUNT TIME/TOTAL 6DIGT 100-240V
Manufacturer
Omron
Type
Count/Time Totalizersr
Datasheets

Specifications of H7HP-A

Count Rate
*
Number Of Digits/alpha
*
Input Type
*
Voltage - Supply
*
Display Type
*
Output Type
*
Voltage Rating
100 V to 240 V
Mounting
Panel
Counting Method
Up, Down or Accumulative
Size
65.8 mm L x 67.7 mm W x 35.7 mm H
Features
NEMA 4 protection using Y92S-32 rubber gasket supplied with unit
No. Of Digits / Alpha
6
Digit Height
15mm
Power Consumption
6.5VA
Counting Speed
5kHz
Operating Temperature Range
-10°C To +55°C
Character Size
15mm
Height
24mm
Mounting Type
Panel
Color
Gray
Connector Type
Screw Terminals
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H7HPA
Compact Total Counters and Time Counters
with Easy-to-read Displays and IP66G/
NEMA4 Water and Oil Resistance
• Large, easy-to-read displays: 15-mm-high characters for 6-digit
• High-visibility, negative transmissive LCD display with built-in
• Compact (66 mm) body.
• Switch 6-digit models between total counter and time counter
Model Number Structure
■ Model Number Legend
1. Classification
2. Digits
Ordering Information
■ List of Models
H7HP-@@@@
100 to 240 VAC
12 to 24 VDC
models; 12-mm-high characters for 8-digit models.
red LED backlight at low power consumption.
operation.
Total Counter/Time Counter (DIN 72 x 36)
H7HP
A:
C:
None: 6 digits
8:
Supply voltage
Total counter/time counter
Total counter
8 digits
1 2 3 4
http://www.ia.omron.com/
H7HP-A
H7HP-AD
Light gray
6-digit total counter/time counter
H7HP-ADB
H7HP-AB
Black
3. Supply Voltage
4. Case Color
None: 100 to 240 VAC
D:
None: Light gray (Munsell 5Y7/1)
B:
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
12 to 24 VDC
Black
H7HP-C8
H7HP-C8D
Light gray
8-digit total counter
H7HP-C8B
H7HP-C8DB
Black
1

H7HP-A Summary of contents

Page 1

... VAC H7HP VDC H7HP-AD http://www.ia.omron.com/ 3. Supply Voltage None: 100 to 240 VAC VDC 4. Case Color None: Light gray (Munsell 5Y7/1) B: Black Black Light gray H7HP-AB H7HP-C8 H7HP-ADB H7HP-C8D (c)Copyright OMRON Corporation 2007 All Rights Reserved. 8-digit total counter Black H7HP-C8B H7HP-C8DB 1 ...

Page 2

... Only a non-voltage input (NPN transistor) is possible for the key protection input. The key protection input will be a non-voltage input even if the NPN/PNP input mode is set to PNP. Key protection is used to prohibit operating the Reset Key. The reset input terminals will still be functional. http://www.ia.omron.com/ H7HP-AD --- VDC 0.6 W max. ...

Page 3

... EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3) EN61000-4- power-line (level 3 I/O signal-line (level 4) EN61000-4- line to lines (power and output lines) (level 2 line to ground (power and output lines) (level 3) (c)Copyright OMRON Corporation 2007 All Rights Reserved. H7HP 3 ...

Page 4

... Count 2 Reset protection input or input or input input start input gate input NPN mode Operation ■ DIP Switch Settings Switches are all set to OFF before shipping. H7HP-A/-AD Pin no. Item OFF 1 Function Total counter 2 Counting speed 30 Hz (note) Time range (note) 99999 Input mode (note) NPN ...

Page 5

... Display 0.0 h Note: 1. Display values are shown for full scale set to 99999.9 h. The count value will return to "0" when "99999.9" is exceeded. 2. Gate input is available only when H7HP-A settings are made. Nomenclature Reset Key Resets the count value, but will not operate while the keys are protected. ...

Page 6

... Dimensions Note: All units are in millimeters unless otherwise indicated. H7HP-A H7HP-C8 Panel Cutouts Panel cutouts are as shown below (according to DIN43700). With Flush Mounting Bracket http://www.ia.omron.com/ M3.5 terminal screw Terminal cover (provided) Note: 1. The mounting panel thickness should mm. 2. Water resistance will be lost if Counters are mounted side-by-side ...

Page 7

... Connections (Common) ■ Input Connections Note: The undermentioned is common for all H7GP/H7HP models. No-voltage Input (NPN Input Mode) Reset, Count 1, Count 2, Start, and Gate Inputs Open Collector Output Voltage Output H7GP/H7HP 12 VDC ( VDC) Sensor Sensor Reset input Count 1 input Count 2 input ...

Page 8

... Use the H7GP/H7HP within the specified ratings for operating temperature and humidity. • Do not operate the H7GP/H7HP in locations subject to sudden or extreme changes in temperature, or locations where high humidity may result in condensation. • Do not use the H7GP/H7HP in locations subject to vibrations or shock ...

Page 9

... Press RST Key or turn power OFF and then ON e2 Memory Labels Unit labels are included with the H7GP/H7HP and DIP switch labels are included with the H7HP. Attach these labels as shown in the following illustrations. Unit Labels H7GP H7HP DIP Switch Labels H7HP ALL DIMENSIONS SHOWN ARE IN MILLIMETERS ...

Page 10

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...