H7HP-C8 Omron, H7HP-C8 Datasheet - Page 4

COUNTER TOTAL 8DIGT 100-240V

H7HP-C8

Manufacturer Part Number
H7HP-C8
Description
COUNTER TOTAL 8DIGT 100-240V
Manufacturer
Omron
Type
Totalizing Counterr
Datasheets

Specifications of H7HP-C8

Count Rate
*
Number Of Digits/alpha
*
Input Type
*
Voltage - Supply
*
Display Type
*
Output Type
*
Analog / Digital
Digital
Voltage Rating
100 V to 240 V
Mounting
Panel
Counting Method
Up or Down (Selectable)
Size
65.8 mm L x 67.7 mm W x 32.7 mm H
No. Of Digits / Alpha
8
Digit Height
12mm
Power Consumption
6.5VA
Counting Speed
5kHz
Operating Temperature Range
-10°C To +55°C
Height
36mm
Mounting Type
Panel
Supply Voltage Min
100VAC
Color
Gray
Connector Type
Screw Terminals
Counter Supply Voltage
100-240VAC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H7HPC8
Connections
■ Terminal Arrangement
Note: 1. Incremented for count 1 (CP1) inputs; decremented for count 2 (CP2) inputs.
Operation
■ DIP Switch Settings
Switches 1 to 4 are all set to OFF before shipping.
H7HP-A@
AC Models
H7HP-A
DC Models
H7HP-AD
1
2
3
4
Pin no.
NPN mode
Power
supply
100 to 240 VAC
5
12 to 24 VDC
0 V
5
2. Non-contact input is also available.
Key
protection
input
Key
protection
input
Power
supply
6
1
Power
supply
Function
Counting speed
(note)
Time range (note) 99999.9 h
Input mode (note) NPN
Unused
6
1
Unused Unused Unused
Reset
input
Unused Unused Unused
Item
Reset
input
7
2
7
2
Count 1
input or
start input
Count 1
input or
start input
8
3
8
3
Total counter
30 Hz
---
External power supply
12 VDC 50 mA max.
Count 2
input or
gate input
Count 2
input or
gate input
9
4
9
4
OFF
Unused Unused
0 V
10
10
NPN mode
PNP mode
12 VDC
PNP mode
11
11
Time counter
5 kHz
99 h 59 min 59 s
PNP
---
ON
H7HP-C8D
Power
supply
100 to 240 VAC
H7HP-C8
5
NPN mode
H7HP-C@
Note: When the setting has been changed, turned power off and on
1
2
3
4
12 to 24 VDC
Pin no.
5
0 V
Key
protection
input
Power
supply
6
1
to continue. The display will show “0” when the power is turned
back on.
Key
protection
input
Power
supply
6
1
Unused Unused Unused
Reset
input
Unused
Counting speed
(note)
Input mode (note) NPN
Unused
7
2
Unused Unused Unused
Reset
input
7
2
Count 1
input
Item
8
3
Count 1
input
8
3
External power supply
12 VDC 50 mA max.
Count 2
input
9
4
Count 2
input
---
30 Hz
---
9
4
0 V
10
Unused Unused
OFF
10
NPN mode
PNP mode
12 VDC
11
11
PNP mode
---
5 kHz
PNP
---
H7HP
ON
4