Specifications of PAXLC600

Count Rate
25kHz
Number Of Digits/alpha
6
Input Type
Voltage
Voltage - Supply
10 V ~ 16 VDC,115 VAC, 230 VAC
Display Type
LED Red
No. Of Digits / Alpha
6
Digit Height
14.2mm
Power Consumption
6VA
Operating Temperature Range
0°C To +60°C
Signal Input Type
Pulse
Character Size
0.56"
Ip/nema Rating
IP65 / NEMA 4X
Connection Type
Cage-Clamp
Cut Out, Panel
3.62×1.77 "
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Function
Counter
Number Of Digits
6
Primary Type
Electronic
Range, Measurement
-99999 to 999999
Special Features
Programmable
Termination
Terminal Block
Voltage, Supply
115/230 VAC, 10 to 16 VDC
Counter Supply Voltage
115/230VAC/10-16VDC
Display Font Color
Red
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
RLC101
3.1 POWER WIRING
3.2 CONTROL INPUT WIRING
Inhibit and Up/Down control. These inputs are active low (connected to
common), so the external switching device should be connected between the
control input and common terminals.
the meter will count up. When input is pulled low, the meter will count down.
remains low or connected to common, the meter will be held in the reset mode,
and not able to count.
input remains low or connected to the common, the meter will not be able to
count.
as long as the input is held low. Once released the display will update to the
current count display.
3.3 INPUT WIRING
Emitter Follower; Current Source
Two Wire Proximity, Current Source
Interfacing With TTL
AC Power
Terminal 1: VAC
Terminal 2: VAC
The PAXLC provides a number of control inputs, including Store, Reset,
Up/Down - This input determines the direction of the count. Unconnected,
Reset - When this input is pulled low, the meter will reset to zero. If the input
Inhibit - When low, this input will prevent the meter from counting. If the
Store - A low will stop the display from updating. It will freeze the display
*Switch position is application dependent.
3
3
3
4
4
4
2.2K
5
5
5
DIODE
1
ON
1
ON
1
ON
2
2
1
2
*
3
2
*
3 4
4
*
3
DC Power
Terminal 3: +VDC
Terminal 4: COMM
4
COMM
+5V
Current Sinking Output
Switch or Isolated Transistor; Current Sink
3
3
3
+
4
-
4
4
5
5
5
ON
ON
1 2 3
1
NPN O.C.
2
*
6
*
3
4
4
7
8
Current Sourcing Output
Switch or Isolated Transistor; Current Source
9
3
3
10
4
4
5
5
ON
ON
1
1
2
2
PNP O.C.
*
3
*
3 4
4