PAXLR000 Red Lion Controls, PAXLR000 Datasheet - Page 7

METER RATE INDICATION 6-DIGIT

PAXLR000

Manufacturer Part Number
PAXLR000
Description
METER RATE INDICATION 6-DIGIT
Manufacturer
Red Lion Controls
Series
PAX®LITEr
Type
Rate Indicatorr
Datasheets

Specifications of PAXLR000

Count Rate
25kHz
Number Of Digits/alpha
6
Input Type
Logic, Transistor
Voltage - Supply
10 V ~ 16 VDC,115 VAC, 230 VAC
Display Type
LED
No. Of Digits / Alpha
6
Signal Input Type
Pulse
Character Size
0.56"
Ip/nema Rating
IP65 / NEMA 4X
Panel Cutout Height
1.77"
Display Font Color
Red
Panel Cutout Width
3.62"
Accuracy
±0.01% %
Connection Type
Cage-Clamp
Cut Out, Panel
3.62×1.77 "
Digit Height
0.56
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Function
Rate Indicator
Number Of Digits
6
Primary Type
Electronic
Range, Measurement
0.01 Hz to 25 kHz
Termination
Terminal Block
Voltage, Supply
115/230 VAC
Counter Supply Voltage
115/230VAC/10-16VDC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
RLC103
the sequence shown above, using the front panel push buttons.
the Rate Scaling Display Value and Rate Scaling Input Value to use for the
specific application.
switch. With the switch in the Disabled (up) position the meter will not enter
programming mode. Refer to the section on DIP switch setup.
PROGRAMMING MODE ENTRY
#$%
PROGRAMMING PARAMETERS
current selection or value for that parameter. The dual display with arrows is
used below to illustrate the alternating display. The selection choices or value
range for each parameter is shown to the right of the alternating display.
selection does not affect scaling calculations.
desired selection is shown. Press the PAR key to save the displayed selection
and advance to the next parameter.
ENTERING NUMERICAL VALUES
with one selected digit flashing (initially the far left digit). Press the " (up
arrow) key to increment the value of the selected (flashing) digit. Holding the
" key automatically scrolls the value of the selected digit.
Use the " key to increment the value of this digit to the desired number. Press
the ! key again to select the next digit to be changed. Holding the ! key
automatically scrolls through each digit position.
numerical value. Press the PAR key to save the displayed value and advance to
the next parameter.
"
updates. The factory setting of 1.0 allows a minimum of one second between
updates. Low values below 0.3 seconds will update the display correctly, but
may cause the display to appear unsteady.
,-#.$"
6.0 P
"
&'( #*
The Rate Indicator has five programmable parameters which are entered in
Before programming, refer to the section on Scaling the Meter to determine
Note: Programming mode can be locked out with the Program Disable DIP
Press the PAR key to enter Programming Mode. The meter briefly displays
In programming mode, the display alternates between the parameter and the
This parameter selects the decimal point position on the display. The
Press the arrow keys (" or !) to sequence through the selection list until the
The parameters which follow are displayed as a multi-digit numerical values
Press the ! (down arrow) key to select the next digit position to the right.
Repeat the “select and set” sequence until all digits are displaying the desired
The Low Update Time is the minimum amount of time between display
For more details on display updating, refer to Input Frequency Calculation.
followed by the first programming parameter described below.
LOW UPDATE TIME (DISPLAY UPDATE)
*+ )
#
#
)
ROGRAMMING THE
DECIMAL POSITION
)+ ) ))
)
)+ *
to
)+ ) )))
00+ 0
)+ )
seconds
)+ ) ))))
)+ ) )
PROGRAMMING SEQUENCE
M
7
ETER
forced to zero. The High Update Time must be higher than the Low Update
Time and also higher than the desired slowest readable speed (one divided by
pulses per second). The factory setting of 2.0 will force the display to zero for
speeds below 0.5 Hz or one pulse every 2 seconds.
Input value entered below. For more explanation, refer to Rate Scaling.
it will be displayed at the same position for this parameter value.
above. This value is always in pulses per second (Hz). For more explanation,
refer to Rate Scaling.
PROGRAMMING MODE EXIT
Rate Scaling Input Value. The meter briefly displays
Programming Mode. All programmed selections are now transferred to the non-
volatile memory and the meter returns to the Rate display.
and reprogram, if necessary, when power is restored.)
PROGRAMMING MODE TIME OUT
activity is detected for approximately 60 seconds, the meter automatically exits
Programming Mode. The meter briefly displays
display. When automatic timeout occurs, any changes that were made to the
parameter currently being programmed, will not be saved.
FACTORY SETTINGS
alternating display illustrations. The factory settings can be easily restored by
removing power from the meter, and then pressing and holding the PAR key
while power is reapplied. The meter displays
released. The normal power-up sequence then resumes, with the factory settings
loaded and saved in non-volatile memory.
position to allow loading factory settings. See section on DIP switch setup.
"
"
"
2'#.$"
!"#$%&
!"#'(&
The High Update Time is the maximum amount of time before the display is
For more details on display updating, refer to Input Frequency Calculation.
Enter the desired Rate Display value to be shown for the corresponding Rate
If a decimal point was selected in the Decimal Position (
Enter the Rate Input value that corresponds to the Rate Display value entered
The meter exits Programming Mode when the PAR key is pressed to save the
(If power loss occurs during programming mode, verify parameter changes
The Programming Mode has an automatic time out feature. If no keypad
The factory settings for the programming parameters are shown above in the
Note: The Program Disable DIP switch must be in the Enabled (down)
*)))+ )
*)))
1+ )
HIGH UPDATE TIME (DISPLAY ZERO)
#
#
#
RATE SCALING DISPLAY VALUE
RATE SCALING INPUT VALUE
)+ 1
to
)
)
to
to
00+ 0
000000
00000+ 0
$','*
seconds
'+&
and returns to the Rate
until the PAR key is
&'( #*
'+&
upon exiting
) parameter,