LD200400 Red Lion Controls, LD200400 Datasheet

COUNTER 4 DIGIT 2.25" 120VAC RED

LD200400

Manufacturer Part Number
LD200400
Description
COUNTER 4 DIGIT 2.25" 120VAC RED
Manufacturer
Red Lion Controls
Series
LDr
Type
Counterr
Datasheets

Specifications of LD200400

Count Rate
35kHz
Number Of Digits/alpha
4
Input Type
Voltage
Voltage - Supply
11 V ~ 16 VDC, 85 V ~ 250 VAC
Display Type
LED Red
No. Of Digits / Alpha
4
Digit Height
57mm
Power Consumption
26VA
Counting Speed
25kHz
Operating Temperature Range
0°C To +50°C
Signal Input Type
Pulse
Character Size
2.25"
Ip/nema Rating
IP65 / NEMA 4X
Connection Type
Wire Leads
Dimensions
12"L×2.25"W×4"H
Display Digit Height
2.25 "
Function
Counter
Material, Casing
Aluminum
Number Of Digits
4
Primary Type
Electronic
Special Features
RS485/RS232 Communications
Termination
Terminal Block
Voltage, Supply
85 to 250/11 to 16 VAC/VDC
Counter Supply Voltage
85-250VAC/11-16VDC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
RLC117
GENERAL DESCRIPTION
dual counter with rate indication, scaling, serial communications and a relay
output. There are also basic models that have a single counter with direction
control only (no scaling or relay output).
with adjustable display intensities. The 2.25" high models are readable up to 130
feet. The 4" high models are readable up to 180 feet. All versions are constructed
of a NEMA 4X enclosure in light weight aluminum.
eight different count modes. These include bi-directional, quadrature and anti-
coincidence counting, as well as a dual counter mode. When programmed as a
dual counter, each counter has separate scaling and decimal point selection.
indicator has separate scaling and decimal point selection, along with
programmable display update times. The meter display can be toggled either
manually or automatically between the count and rate values.
selectable RS232 or RS485 serial communications.
SAFETY SUMMARY
corresponding literature, or on equipment, must be observed to ensure personal
safety and to prevent damage to either the instrument or equipment connected to
it. If equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
MODEL LD - LARGE DISPLAY
The Large Display is a versatile display that can be configured as a single or
The 4 & 6 digit displays are available in either 2.25" or 4" high red LED digits
The 6-digit programmable models have two signal inputs and a choice of
Rate indication is available on the programmable models only. The rate
The programmable models also come with a Form C relay output and jumper
All safety regulations, local codes and instructions that appear in this and
installation and operation of the unit.
4
Read complete instructions prior to
CAUTION: Risk of Danger.
CAUTION: Risk of electric shock.
SPECIFICATIONS
1. DISPLAY: 2.25" (57 mm) or 4" (101 mm) intensity adjustable Red LED
2. POWER REQUIREMENTS:
3. COUNT INPUT(S):
2.25" & 4" HIGH RED LED DIGITS
AVAILABLE IN 4 OR 6 DIGIT VERSIONS
SINGLE OR DUAL COUNTER with RATE INDICATOR *
PROGRAMMABLE SCALING AND DECIMAL POINTS *
PROGRAMMABLE USER INPUT *
AC OR DC POWERED
5 AMP FORM C RELAY *
ALUMINUM NEMA 4X CASE CONSTRUCTION
AC POWER:
DC POWER:
LD200400, LD200600, LD400400, & LD400600:
LD2006P0 & LD4006P0:
AC Input: 85 to 250 VAC 50/60 Hz, 14 VA
DC Out: 11 to 16 VDC @ 50 mA (consult factory for higher current draw)
DC Input: 11 to 16 VDC @ 400 mA max, 7 W
Counter(s) have DIP switch selectable pull-up (7.8 KΩ) or pull-down
Counters are DIP switch selectable for high or low frequency (Damping
Input A Trigger levels: V
Input B Trigger levels: V
Counter Overflow Indication: Display flashes "
Count Speed: 35 KHz max. @ 50% duty cycle (no scaling)
Counter A & B Frequency:
resistors (3.9 KΩ) that determine active high or active low input logic.
capacitor provided for switch contact bounce. Limits input frequency to
50 Hz and input pulse widths to 10 msec min.)
CNT UD
RT-CNT
QUAD X1; QUAD X2
QUAD X4; DUAL CNT 16K
ADD/ADD; ADD/SUB
* Programmable models only
COUNT MODE
parts of the equipment for safety purposes and must be
connected to an external protective earthing system.
The protective conductor terminal is bonded to conductive
IL
IL
= 1.25 V max; V
LD2004xx 12 (304.8)
LD2006xx 16 (406.4)
LD4004xx 20 (508)
LD4006xx 26 (660.4)
= 1.0 V max; V
NUMBER
35K
25K
22K
20K
MAX FREQUENCY
PART
X (Length)
IH
IH
= 2.75 V min; V
= 2.4 V min; V
4 (101.6)
4 (101.6)
7.875 (200)
7.875 (200)
Y (Height)
"
MAX
MAX
8 (203.2)
12 (304.3)
16 (406.4)
22 (558.8)
Z (Center)
= 28 VDC
= 28 VDC

LD200400 Summary of contents

Page 1

... Limits input frequency and input pulse widths to 10 msec min.) Input A Trigger levels: V Input B Trigger levels: V Counter Overflow Indication: Display flashes " LD200400, LD200600, LD400400, & LD400600: Count Speed: 35 KHz max. @ 50% duty cycle (no scaling) LD2006P0 & LD4006P0: Counter A & B Frequency: CNT UD RT-CNT QUAD X1 ...

Page 2

... High 6-Digit Red LED Count/Rate Indicator w/ Relay Output & RS232/RS485 Serial Communications EN 61000-4-2 Criterion contact discharge 8 kV air discharge EN 61000-4-3 Criterion 61000-4-4 Criterion power 1 kV signal 2 EN 61000-4-5 Criterion L- L&N-E power EN 61000-4-6 Criterion A 3 V/rms EN 55011 Class B PART NUMBER LD200400 LD200600 LD400400 LD400600 LD2006P0 LD4006P0 ...