LD200400 Red Lion Controls, LD200400 Datasheet - Page 2

COUNTER 4 DIGIT 2.25" 120VAC RED

LD200400

Manufacturer Part Number
LD200400
Description
COUNTER 4 DIGIT 2.25" 120VAC RED
Manufacturer
Red Lion Controls
Series
LDr
Type
Counterr
Datasheets

Specifications of LD200400

Count Rate
35kHz
Number Of Digits/alpha
4
Input Type
Voltage
Voltage - Supply
11 V ~ 16 VDC, 85 V ~ 250 VAC
Display Type
LED Red
No. Of Digits / Alpha
4
Digit Height
57mm
Power Consumption
26VA
Counting Speed
25kHz
Operating Temperature Range
0°C To +50°C
Signal Input Type
Pulse
Character Size
2.25"
Ip/nema Rating
IP65 / NEMA 4X
Connection Type
Wire Leads
Dimensions
12"L×2.25"W×4"H
Display Digit Height
2.25 "
Function
Counter
Material, Casing
Aluminum
Number Of Digits
4
Primary Type
Electronic
Special Features
RS485/RS232 Communications
Termination
Terminal Block
Voltage, Supply
85 to 250/11 to 16 VAC/VDC
Counter Supply Voltage
85-250VAC/11-16VDC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
RLC117
4. RATE INPUT: Models LD2006P0 & LD4006P0 only
5. RESET/USER INPUT:Function programmable for LD2006P0 &LD4006P0
6. COMMUNICATIONS (LD2006P0 & LD4006P0 only):
7. MEMORY: Nonvolatile E
8. OUTPUT (LD2006P0 & LD4006P0 only):
9. ENVIRONMENTAL CONDITIONS:
10. CONNECTIONS:
Display Range: 0 to 99999
Min Freq.: 0.01 Hz
Max Freq.: See Frequency chart under Count Input specification
Accuracy: ±0.01%
Rate Overflow Indication: Display flashes "
Reset/User Input: DIP switch selectable pull-up (7.8 KΩ) or pull-down
Trigger levels: V
Response Time: 5 msec typ.; 100 msec debounce (activation and release)
RS485 SERIAL COMMUNICATIONS
RS232 SERIAL COMMUNICATIONS
count values when power is removed.
Relay: Form C contacts rated at 5 amps @ 120/240 VAC or 28 VDC (resistive
Operating temperature: 0 to 50 °C
Storage temperature: -40 to 70 °C
Operating and storage humidity: 0 to 85% max. RH (non-condensing)
Altitude: Up to 2,000 meters
Internal removable terminal blocks are used for power and signal wiring.
Remove end plates with ¼" nut driver. For LD4 versions, all wiring is on right
side of unit. For LD2 versions, power and signal wiring is on the right side
and the optional relay output is on left side.
Wire Strip Length: 0.4" (10 mm)
Wire Gage: 24-12 AWG copper wire
Torque: 5.3 inch-lbs (0.6 N-m) max.
resistor (3.9 KΩ) that determines active high or active low input logic.
Type: RS485 multi-point balanced interface (non-isolated)
Baud Rate: 300 to 19.2 k
Data Format: 7/8 bits; odd, even, or no parity
Bus Address: 0 to 99; max 32 meters per line
Type: RS232 half duplex (non-isolated)
Baud Rate: 300 to 19.2 k
Data Format: 7/8 bits; odd, even, or no parity
load), 1/8 H.P. @ 120 VAC (inductive load)
IL
Programmable
= 1.0 V max; V
panel keys)
panel keys)
(With front
(No front
Basic
TYPE
2
PROM retains all programming parameters and
IH
MODEL NO.
= 2.4 V min; V
LD
LD
DESCRIPTION
2.25" High 4-Digit Red LED Counter
2.25" High 6-Digit Red LED Counter
4" High 4-Digit Red LED Counter
4" High 6-Digit Red LED Counter
2.25" High 6-Digit Red LED Count/Rate Indicator w/
Relay Output & RS232/RS485 Serial Communications
4" High 6-Digit Red LED Count/Rate Indicator w/ Relay
Output & RS232/RS485 Serial Communications
"
MAX
= 28 VDC
11. CERTIFICATIONS AND COMPLIANCES:
12. CONSTRUCTION: Aluminum enclosure, and steel side panels with textured
13. WEIGHT:
SAFETY
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment for
IP65 Enclosure rating (Face only), IEC 529
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for
Notes:
black polyurethane paint for scratch and corrosion resistance protection. Sealed
front panel meets NEMA 4X/IP65 specifications. Installation Category II,
Pollution Degree 2.
LD2004XX - 3.5 lbs (1.59 kg)
LD2006XX - 4.5 lbs (2.04 kg)
LD4004XX - 8 lbs (3.63 kg)
LD4006XX - 10.5 lbs (4.76 kg)
Immunity to Industrial Locations:
Electrostatic discharge
Electromagnetic RF fields
Fast transients (burst)
Surge
RF conducted interference
Emissions:
Emissions
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
Type 4X Enclosure rating (Face only), UL50
measurement, control, and laboratory use, Part 1.
Measurement, Control and Laboratory use.
1. Criterion A: Normal operation within specified limits.
2. DC Power: Shaffner FN610-1/07 line filter installed on DC power cable
to comply.
PART NUMBER
LD2006P0
LD4006P0
LD200400
LD200600
LD400400
LD400600
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 55011
Criterion A
4 kV contact discharge
8 kV air discharge
Criterion A
10 V/m
Criterion A
2 kV power
1 kV signal
Criterion A
1 kV L-L,
Criterion A
3 V/rms
Class B
2 kV L&N-E power
2
2