COUNTER 4 DIGIT 2.25" 120VAC RED

LD200400

Manufacturer Part Number
LD200400
Description
COUNTER 4 DIGIT 2.25" 120VAC RED
Manufacturer
Red Lion Controls
Series
LDr
Type
Counterr
Datasheets

Specifications of LD200400

Count Rate
35kHz
Number Of Digits/alpha
4
Input Type
Voltage
Voltage - Supply
11 V ~ 16 VDC, 85 V ~ 250 VAC
Display Type
LED Red
No. Of Digits / Alpha
4
Digit Height
57mm
Power Consumption
26VA
Counting Speed
25kHz
Operating Temperature Range
0°C To +50°C
Signal Input Type
Pulse
Character Size
2.25"
Ip/nema Rating
IP65 / NEMA 4X
Connection Type
Wire Leads
Dimensions
12"L×2.25"W×4"H
Display Digit Height
2.25 "
Function
Counter
Material, Casing
Aluminum
Number Of Digits
4
Primary Type
Electronic
Special Features
RS485/RS232 Communications
Termination
Terminal Block
Voltage, Supply
85 to 250/11 to 16 VAC/VDC
Counter Supply Voltage
85-250VAC/11-16VDC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
RLC117
5. RESET/USER INPUT: Function programmable for LD2006P0 &LD4006P0
6. COMMUNICATIONS (LD2006P0 & LD4006P0 only):
7. MEMORY: Nonvolatile E
8. OUTPUT (LD2006P0 & LD4006P0 only):
9. ENVIRONMENTAL CONDITIONS:
10. CONNECTIONS:
INSTALLATION
INSTALLATION ENVIRONMENT
temperature. Placing the unit near devices that generate excessive heat should
be avoided. The unit should only be cleaned with a soft cloth and neutral soap
product. Do NOT use solvents.
the front overlay. Do not use tools of any kind (screwdrivers, pens, pencils, etc.)
to operate the keypad of the unit.
1.0 I
Reset/User Input: DIP switch selectable pull-up (7.8 K) or pull-down
Trigger levels: V
Response Time: 10 msec typ.; 50 msec debounce (activation and release)
RS485 SERIAL COMMUNICATIONS
RS232 SERIAL COMMUNICATIONS
count values when power is removed.
Type: Dual Form C contacts
Contact Rating: 5 amps @ 120/240 VAC or 28 VDC (resistive load), 1/8
Life Expectancy: 100 K cycles min. at full load rating. External RC snubber
Response Time: Turn On or Off: 5 msec max.
Isolation to Input & User/Exc Commons: 2000 Vrms for 1 min.
Operating temperature: 0 to 65 °C
Storage temperature: -40 to 70 °C
Operating and storage humidity: 0 to 85% max. RH (non-condensing)
Vibration According to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z
Shock According to IEC 68-2-27: Operational 30 g’s (10g relay), 11 msec in
Altitude: Up to 2,000 meters
Internal removable terminal blocks are used for power and signal wiring.
Remove end plates with ¼" nut driver. For LD4 versions, all wiring is on right
side of unit. For LD2 versions, power and signal wiring connections are on
the right side and the relays and serial options are on the left side.
Wire Strip Length: 0.4" (10 mm)
Wire Gage: 24-12 AWG copper wire, 90°C rated insulation only
Torque: 5.3 inch-lbs (0.6 N-m) max.
Cable Diameter: Outside diameter must be 0.181" (4.6 mm) to 0.312" (7.9
The meter meets NEMA 4X/IP65 requirements when properly installed.
The unit should be installed in a location that does not exceed the operating
Continuous exposure to direct sunlight may accelerate the aging process of
resistor (3.9 K) that determines active high or active low input logic.
Type: RS485 multi-point balanced interface (isolated)
Baud Rate: 300 to 38.4 k
Data Format: 7/8 bits; odd, even, or no parity
Bus Address: 0 to 99; max 32 meters per line
Type: RS232 half duplex (isolated)
Baud Rate: 300 to 38.4 k
Data Format: 7/8 bits; odd, even, or no parity
H.P. @ 120 VAC (inductive load)
extends relay life for operation with inductive loads.
Working Voltage: 240 Vrms
direction for 1.5 hours, 2 g’s (1g relay).
3 directions.
mm) to maintain NEMA 4 rating of cord grips.
ORDERING INFORMATION
Programmable
NSTALLING THE
panel keys)
panel keys)
IL
(With front
(No front
= 1.0 V max; V
Basic
TYPE
2
PROM retains all programming parameters and
MODEL NO.
LD Plug
IH
LD
LD
= 2.4 V min; V
DESCRIPTION
2.25" High 4-Digit Red LED Counter
2.25" High 6-Digit Red LED Counter
4" High 4-Digit Red LED Counter
4" High 6-Digit Red LED Counter
2.25" High 6-Digit Red LED Count/Rate Indicator w/ dual Relay Output &
RS232/RS485 Serial Communications
4" High 6-Digit Red LED Count/Rate Indicator w/ dual Relay Output & RS232/
RS485 Serial Communications
Panel Meter Plug for LD models
MAX
= 28 VDC
M
ETER
2
11. CERTIFICATIONS AND COMPLIANCES:
12. CONSTRUCTION: Aluminum enclosure, and steel side panels with textured
13. WEIGHT:
MOUNTING INSTRUCTIONS
be wall mounted or suspended
from a ceiling truss or other
suitable structure capable
of supporting the LD.
Caution should be exercised
when hanging the display to
provide for the safety of
personnel. If hanging the LD,
run the suspension cables (or
chains) through the mounting
bracket holes. For wall mounting
use #10-32 size bolts.
SAFETY
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
Type 4X Enclosure rating, UL50
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment for
IP65 Enclosure rating, IEC 529
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for Measurement,
Notes:
black polyurethane paint for scratch and corrosion resistance protection. Meets
NEMA 4X/IP65 specifications. Installation Category II, Pollution Degree 2.
LD2004XX: 3.5 lbs (1.59 kg)
LD2006XX: 4.5 lbs (2.04 kg)
LD4004XX: 8 lbs (3.63 kg)
LD4006XX: 10.5 lbs (4.76 kg)
This display is designed to
Immunity to Industrial Locations:
Electrostatic discharge
Electromagnetic RF fields
Fast transients (burst)
Surge
RF conducted interference
Voltage dip/interruptions
Emissions:
Emissions LD200400
Emissions LD2006P0
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
measurement, control, and laboratory use, Part 1.
Control and Laboratory use.
1. Criterion A: Normal operation within specified limits.
2. Criterion B: Temporary loss of performance from which the unit self-
recovers.
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-11
EN 55011
EN 55011
PART NUMBER
LDPLUG00
LD2006P0
LD4006P0
LD200400
LD200600
LD400400
LD400600
Criterion A
4 kV contact discharge
8 kV air discharge
Criterion A LD200400
Criterion B LD2006P0
10 V/m
Criterion A
2 kV power
1 kV signal
Criterion A
1 kV L-L,
Criterion A
3 V/rms
Criterion A
0.5 cycle
Class B
Class A
2 kV L&N-E power
MOUNTING HOLE (.281")
TERMINAL #3 (TBA)
MUST BE
CONNECTED TO