H7CX-A4D DC12-24Q Omron, H7CX-A4D DC12-24Q Datasheet - Page 17

COUNTER DGTL 4DIGIT 12V SRW TERM

H7CX-A4D DC12-24Q

Manufacturer Part Number
H7CX-A4D DC12-24Q
Description
COUNTER DGTL 4DIGIT 12V SRW TERM
Manufacturer
Omron
Series
H7CXr
Type
Digital Panel Meterr

Specifications of H7CX-A4D DC12-24Q

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
4
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Switch Closure
Voltage - Supply
12 V ~ 24 V
Display Type
LCD Programmable Color
Equipment Type
Digital Panel Meter
Input
4.5 V to 30 V
Termination Style
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CX-A4D DC12-24
H7CXA4DDC1224
Z2739
To previous
page
From previous
page
Absolute value
setting/forecast
value setting
(SETM)
Key protect
level
(KYPT)
Set value
upper limit
(SL-H)
Forecast
setting
upper limit
(PL-H)
Output
allocation
change
Batch count
upper limit
(BL-H)
*8
Output ON
count alarm set
value/monitor
value
Note: 1 to 999999 for 6-digit models.
Note: Displayed only when the output mode is set to bcnt.
Note:
Note: 1 to 999999 for 6-digit models.
Note: Displayed only when the configuration selection mode is set to the 2-stage function 2cnt and a forecast value is set.
• Make the absolute value setting and forecast setting using the U (D) Keys.
• Set each digit using the individual U (D) Keys.
Note: 1 to 999999 for 6-digit models
• Set each digit using the individual U (D) Keys.
Note: Displayed only when the configuration selection mode is set to the 2-stage function 2cnt.
• Set each digit using the individual U (D) Keys.
• Set the key protect level using the U (D) Keys.
(ABS)
(OFF)
abs
kp-1
(KP-1)
off
( 1 )
( 1 )
( 1 )
Displayed only for "-AU@" models.
off: Output 1 = 12, 13, Output 2 = 3, 4, 5 on: Output 1 = 3, 4, 5, Output 2 = 12, 13
The numbers are the terminals numbers.
1
1
1
(OFST)
ofst
(ON)
(KP-2)
kp-2
9999
( 9999 )
9999
( 9999 )
9999
( 9999 )
on
kp-3
(KP-3)
*8 Set each digit using the individual U (D) Keys.
Procedure for Models Other than “-@W@” Models
Procedure for “-@W@” Models
(KP-4)
kp-4
kp-5
(KP-5)
Output
ON count
alarm set
value
Output 1
(OUT1) ON
count alarm
set value
Output 1
(OUT1) ON
count monitor
value
Output 2
(OUT2) ON
count monitor
value
Output
ON count
monitor
value
Output 2
(OUT2) ON
count alarm
set value
kp-6
(KP-6)
kp-7
(KP-7)
Note: The monitor value is only displayed. It cannot be set.
Note: The monitor value is only displayed. It cannot be set.
Note: The monitor value is only displayed. It cannot be set.
(0 1000 times)
(0 1000 times)
(0 1000 times)
0
0
0
(9999 1000 times)
(9999 1000 times)
(9999 1000 times)
9999
9999
9999
H7CX-A@-N
Counter
17