H7CX-A4D DC12-24Q Omron, H7CX-A4D DC12-24Q Datasheet - Page 22

COUNTER DGTL 4DIGIT 12V SRW TERM

H7CX-A4D DC12-24Q

Manufacturer Part Number
H7CX-A4D DC12-24Q
Description
COUNTER DGTL 4DIGIT 12V SRW TERM
Manufacturer
Omron
Series
H7CXr
Type
Digital Panel Meterr

Specifications of H7CX-A4D DC12-24Q

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
4
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Switch Closure
Voltage - Supply
12 V ~ 24 V
Display Type
LCD Programmable Color
Equipment Type
Digital Panel Meter
Input
4.5 V to 30 V
Termination Style
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CX-A4D DC12-24
H7CXA4DDC1224
Z2739
22
H7CX-A@-N
Counter
Input/Output Mode Settings
I/O Functions for Counter Operation
If a 1-stage model or 2-stage model is incorrectly used as twin counter, the operation for
output 2 will be performed. When using a 2-stage model as a 1-stage preset counter,
total and preset counter, or dual counter, OUT1 and OUT2 turn ON and OFF
simultaneously.
Output
mode
setting
K-1
N
C
R
F
Set value 2
Set value 1
Set value 2
Set value 1
Set value 2
Set value 1
Set value 2
Set value 1
Set value 2
Set value 1
999999
999999
999999
999999
reset 1
reset 1
999999
reset 1
reset 1
reset 1
Reset/
OUT1
OUT2
Reset/
OUT1
OUT2
Reset/
OUT1
OUT2
Reset/
OUT1
OUT2
Reset/
OUT1
OUT2
0
0
0
0
0
UP
Input mode
DOWN
Self-holding
output
UP/DOWN A, B, C
One-shot output from OUT1
Self-holding
output
output from OUT2
One-shot
(The one-shot output time can be
set in the range 0.01 to 99.99s.)
The outputs and present
value display are held
until reset/reset 1 is
input.
The present value
display continues to
increase/decrease.
The outputs are held until
reset/reset 1 is input.
As soon as the count
reaches SV, the present
value display returns to
the reset start status.
The present value display
does not show the
present value upon count-
up.
The outputs repeat one-
shot operation.
OUT1 self-holding output
turns OFF after the OUT2
one-shot output time.
The OUT1 one-shot
output time is
independent of OUT2.
The present value
display returns to the
reset start status after
the one-shot output time.
The outputs repeat one-
shot operation.
OUT1 self-holding output
turns OFF after the
OUT2 one-shot output
time.
The OUT1 one-shot
output time is
independent of OUT2.
The present value
display continues to
increase/decrease.
OUT1 self-holding output
turns OFF after the
OUT2 one-shot output
time.
The OUT1 one-shot
output time is
independent of OUT2.
Operation after count