ACA-20RM-1-AC3-RL-C Murata Power Solutions Inc, ACA-20RM-1-AC3-RL-C Datasheet - Page 2

METER LED 120VAC 2A TRU-RMS RED

ACA-20RM-1-AC3-RL-C

Manufacturer Part Number
ACA-20RM-1-AC3-RL-C
Description
METER LED 120VAC 2A TRU-RMS RED
Manufacturer
Murata Power Solutions Inc
Type
Ammeterr
Series
ACA-20RMr
Datasheet

Specifications of ACA-20RM-1-AC3-RL-C

Display Type
LED
Measuring Range
0 ~ 1.999A
Display Style
Red Characters, Black Background
Display Digits
3.5
Display Digits - Height
0.370" (9.40mm)
Backlight
Without
Mounting Type
Panel Mount
Termination
Terminal Block
Voltage - Supply
85 ~ 140VAC
Equipment Type
AC Ammeters
Primary Voltage Rating
85 V to 140 V
Secondary Current Rating
30 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Display Face Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-1111
Performance/Functional Specifi cations
Typical at T
Rated Full-Scale Current ➀
ACA-20RM-O-ACX-RL
ACA-20RM-1-ACX-RL
ACA-20RM-2-ACX-RL
ACA-20RM-4-ACX-RL
ACA-20RM-5-ACX-RL
Overcurrent Rating ➁
Performance
Sampling Rate
Accuracy ➂
Measurement Type
Temperature Drift (0 to 60 °C)
Zero-Current Reading (within
30 sec.)
Dielectric Withstanding Voltage
Power Supply Voltage
ACA-20RM-X-AC3-RL
ACA-20RM-X-AC4-RL
Power Supply Current ➃
ACA-20RM-X-AC3-XX
ACA-20RM-X-AC4-XX
Power Supply Terminal Block
Wire Size
Insulation Strip Length
Screw Tightening Torque
Rated Voltage
Display
Display Type and Size
Overrange Indication
Decimal Point
Physical/Environmental
Operating Temperature
Storage Temperature
Humidity
Dimensions (non-condensing)
Weight
ACA-20RM-0,1,2-XXX-XX
ACA-20RM-4-XXX-XX
ACA-20RM-5-XXX-XX
A
= +25°C, unless otherwise noted.
–001
2000
Min.
RMS Responding, Crest Factors of 1-5
170
–40
–40
3½ Digit Red LED, 0.37”/9.4mm High
85
0
Model dependent, see page 3 & 4
±0.4%FS ±3 Counts with 60Hz
1.1 ounces (31 grams) nominal
2.1 ounces (60 grams) nominal
1.5 ounces (43 grams) nominal
16-22AWG, Solid and stranded
1.5 x Rated Full-Scale Current
(see full-scale input Current)
3.6 pounds-inches (0.4Nm)
2.5 Samples per second
Fixed, model dependent
±0.2
Typ.
000
120
220
30
30
Sine-Wave Input
0.250 inches
“1___”
310Vac
199.9
1.999
19.99
Max.
±0.4
50.0
30.0
001
140
264
+60
+75
+95
50
50
Vac/47-63Hz
Vac/47-63Hz
mA/47-63Hz
mA/47-63Hz
Cnts/°C
www.murata-ps.com/dpm
Units
Cnts
Vdc
mA
°C
°C
%
A
A
A
A
➀ Specifi ed full-scale currents are those passing through the ammeter’s built-in
➁ The overcurrent rating of 1.5 x the rated full-scale current is a continuous rating
➂ Specifi ed accuracy applies to inputs with crest factors (CF) up to 2.0, where CF
➃ All specifi ed maximum power supply currents are steady state; larger surge
TECHNICAL NOTES
1. Measurement Type: ACA-20RM ac ammeters employ true-rms
2. Calibration: Periodic recalibration of ACA-20RM ammeters is not
ACA-20RM- 1 - AC3 - R L - C
Input Range:
0 = 199.9mA
1 = 1.999A
2 = 19.99A
4 = 50.0A (with split-core fl ying-lead CT)
5 = 30.0A (with fl ying-lead CT)
current transformer’s primary load-circuit. See Notes 2 and 3 below for ad-
ditional model-specifi c information.
and applies to the current passing through the built in current transformer only,
it does not apply to any external circuit-wiring or external loads. Accuracy is
guaranteed up to the rated current level.
= Vpeak/Vrms. Crest factors of 2 to 5 introduce an additional error of ±3% of full
scale. Ammeters are calibrated with a near full-scale 60Hz sine-wave current
fl owing through the ammeter’s built-in CT.
currents can occur at initial application of line power.
Ordering Information
IMPORTANT! To ensure safe and reliable operation, ACA-20RM
ammeters must be installed and serviced by qualifi ed technical
personnel after reading this data sheet in it's entirety. Contact DATEL
if there is any doubt regarding their installation or
operation.
input circuitry to measure the stepped-down output of their on-board
current transformers (CT). Stated accuracy is measured using a sine-
wave input at, or close to, the specifi ed full scale input, at a nominal
line frequency of 60HZ.
required under normal indoor environments. If user calibration is
deemed necessary, it must be performed by qualifi ed technical
personnel since potentially lethal voltages and currents are applied to
the ACA-20RM during the calibration process.
Calibration is performed with approximately 95% of the specifi ed
full-scale current fl owing through the ammeter’s built-in CT. A fully
insulated, non-metallic adjusting tool must be used to adjust the
calibration potentiometer, located on the back of the ammeter (see
Mechanical Specifi cations section).
Accessories:
DMS-20-CP Panel Cutout Punch
True-RMS-AC Ammeters with Built-in CT
26 Jan 2011 MPM_ACA-20RM_B05 Page 2 of 5
ACA-20RM Series
Power:
AC3 = 85-140Vac@50/60Hz
AC4 = 170-264Vac@50/60Hz
email: sales@murata-ps.com
LED Color:
RL = Low-Power Red
Add -C for RoHS