PAXLID00 Red Lion Controls, PAXLID00 Datasheet - Page 6

METER DC CURRENT 3 1/2-DIGIT

PAXLID00

Manufacturer Part Number
PAXLID00
Description
METER DC CURRENT 3 1/2-DIGIT
Manufacturer
Red Lion Controls
Series
PAX®LITEr
Type
Ammeterr
Datasheet

Specifications of PAXLID00

Measuring Range
0 ~ 199.9mA
Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.80" L x 1.95" W (96.5 x 49.5mm)
Display Digits
3.5
Display Digits - Height
0.560" (14.22mm)
Backlight
Without
Mounting Type
Panel Mount
Termination
Terminal Block
Voltage - Supply
115VAC,230 VAC
No. Of Digits / Alpha
3-1/2
Meter Function
DC Ammeter
Meter Range
199.9uA To 1.999A
Digit Height
14.2mm
Power Consumption
6VA
Operating Temperature Range
0°C To +60°C
Supply Voltage Ac, Min
115V
Accuracy
±0.1% (199.9 µA to 19.99 mA)
Connection Type
Cage-Clamp
Cut Out, Panel
3.62×1.77 "
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Display Resolution
0.1 μA to 1 mA
Function
Ammeter
Meter Type
DC Current
Number Of Digits
3-1/2
Primary Type
Electronic
Range, Measurement
199.9 μADC to 1.999 ADC
Special Features
Multi-Range Unit
Standards
cULus Listed, CE Marked
Temperature, Operating
0 to 60 °C
Time, Response
1 Second nominal
Voltage, Supply
115/230 VAC
Weight
0.65 lbs
Character Size
0.56"
Display Font Color
Red
Rohs Compliant
NA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
RLC105
3.1 POWER WIRING
DIRECT VOLTMETER READOUT
should remain in the “OFF” position. The Input Range Jumper is set to the
voltage range being applied. It is possible to select a range higher than being
applied to get lower resolution. The Decimal Point switches are set to resolution
of the selected Input Range Jumper.
SCALING VOLTMETER READOUT
in terms of PSI, RPM, or some other unit of measure. The signal voltage being
measured can be generated by a transducer that senses the variations and
delivers a linear output voltage. To provide the desired readout at the specified
voltage, the voltmeter must be scaled.
Potentiometer which is accessible from the back of the meter. (Enabling the
Scale Potentiometer does NOT affect the calibration of the meter.) Place the
Decimal Point Switches to the proper location. To properly set the Input Range
Jumper, the Division Factor must be determined by first using the below formula.
After the Division Factor is calculated, use the Division Factor Range Selection
Chart to choose the proper Input Range Jumper setting. Apply the meter power
and the voltage signal. Adjust the Scale Potentiometer to the desired value.
only zero voltage can display a value of zero.
WHERE:
voltage range jumper can be selected. Use the “Division Factor Range Selection
Chart” to choose the proper jumper setting.
PAXLV
4.0 S
When the application requires direct voltmeter readout, the Scale Switch
In many industrial applications, a voltmeter is required to display a reading
Place the Scale Switch in the “ON” position. This enables the Scale
This scaling only effects the span. There is no offset scaling. This means that
DIVISION FACTOR FORMULA:
After the Division Factor for the application has been calculated, the proper
AC Power
Terminal 1: VAC
Terminal 2: VAC
0.000 = 1
00.00 = 10
000.0 = 100
0000
D.D.P
D.R.
D.F.
D.D.P.
VT
CALING THE
= 1000
= Maximum Transducer Output
= Display Decimal Point
= Division Factor
= Desired Reading
115/230
1
VT x D.D.P.
D.R.
2
The Display Decimal Point
(D.D.P.) is determined by
the desired decimal point
placement in the readout.
= D.F.
M
3.2 INPUT SIGNAL WIRING
PAXLV
Voltage Signal (self powered)
Terminal 4: + Volts DC/AC
Terminal 3: - Volts DC/AC
Before connecting signal wires, the Input Range Jumper should be verified for proper position.
ETER
3
300V MAX.
-
4
V
6
+
the voltage signal is applied.
COMMON
EXAMPLE: A relative humidity transducer delivers a 7.0 VDC voltage at a
(199.9 V) is selected. The Scaling Potentiometer is then adjusted for the desired
readout at a known relative humidity.
+SIGNAL
DIVISION FACTOR RANGE SELECTION CHART
Note: Only one voltage jumper should be selected. Install the jumper before
relative humidity of 75%.
This Division Factor is between 10.5 and 100.5, therefore jumper position 3
100.5 to 1300
10.5 to 100.5
1.2 to 10.5
0.1 to 1.2
D.F.
900K
90K
9K
1K
D.F. = VT x D.D.P. = 7.0 x 1000 = 93.3
BLOCK DIAGRAM PAXLV
0-1.999V
0-19.99V
0-199.9V
0-300V
Use Input Position
Pos 1: 0-1.999 VDC
Pos 2: 0-19.99
Pos 3: 0-199.9
Pos 4: 0-300
PAXLI
Current Signal (self powered)
Terminal 4: + Amps DC/AC
Terminal 3: - Amps DC/AC
D.R.
SCALE
POT
S5
+VDC
-
2A MAX.
75
3
A
S3
4
+
S2
S1
S4