K3HB-XVD 100-240VAC Omron, K3HB-XVD 100-240VAC Datasheet - Page 14

PROCESS INDICATR DC VOLTAG INPUT

K3HB-XVD 100-240VAC

Manufacturer Part Number
K3HB-XVD 100-240VAC
Description
PROCESS INDICATR DC VOLTAG INPUT
Manufacturer
Omron
Series
K3HBr
Type
Process Meterr
Datasheet

Specifications of K3HB-XVD 100-240VAC

Measuring Range
0 ~ 199.99V
Display Style
Green, Red Characters, Black Background
Display Type
LCD
Display Face Size
3.78" L x 1.89" W (96.0 x 48.0mm)
Display Digits
5
Display Digits - Height
0.193" (4.90mm), 0.559" (14.20mm)
Backlight
Green, Red
Mounting Type
Panel Mount
Termination
Screw Terminals
Voltage - Supply
100 ~ 240VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
K3HB-XVD100-240VAC
K3HBXVD100240VAC
K3HB-H Temperature Indicator
New High-speed, High-precision Temperature
Indicator
• Easy recognition of judgement results using color display
• Equipped with a position meter for monitoring operating
• External event input allows use in various measurement and
• Series expanded to include DeviceNet models.
• Short body with depth of only 95 mm (from behind the front
• UL certification approval (Certification Mark License).
• CE Marking conformance by third party assessment body.
• Water-resistant enclosure conforms to NEMA 4X (equivalent
• Capable of high-speed sampling at 50 times per second
• High-resolution of 0.01°C with platinum-resistance
• Temperature input shift is easily set using two points.
Model Number Structure
■ Model Number Legend
Base Units and Optional Boards can be ordered individually.
Base Units
1. Input Sensor Codes
2. Supply Voltage
K3HB-H@
that can be switched between red and green.
status trends.
discrimination applications.
panel), or 97 mm for DeviceNet models.
to IP66).
(20 ms).
thermometer Pt100 input. Thermocouple sensor inputs also
support a resolution of 0.1°C for all ranges.
TA: Temperature input,
100240VAC: 100 to 240 VAC
24VACVDC: 24 VAC/VDC
Thermocouple input/Platinum resistance
Thermometer input
1
2
Optional Boards
Sensor Power Supply/Output Boards
3. Sensor Power Supply/Output Type Codes
Note: 1. CPA and CPB can be combined with relay outputs only.
K33-@
FLK3B: Communications (RS-485) + Sensor power supply
None: None
CPA:
CPB:
L1A:
L1B:
L2A:
L2B:
A:
B:
FLK1A: Communications (RS-232C) + Sensor power supply
FLK1B: Communications (RS-232C) + Sensor power supply
FLK3A: Communications (RS-485) + Sensor power supply
2. Only one of communications, BCD, or DeviceNet can be
3
used by each Digital indicator.
Sensor power supply (12 VDC +/
Sensor power supply (10 VDC +/
Relay output (PASS: SPDT) + Sensor power supply
Linear current output (DC0(4)
Linear current output (DC0(4)
Linear voltage output (DC0(1)
Linear voltage output (DC0(1)
Relay output (PASS: SPDT) + Sensor power supply
Temperature Indicator
(12 VDC +/
(10 VDC +/
(12 VDC +/
(10 VDC +/
(12 VDC +/
(10 VDC +/
(12 VDC +/
(10 VDC +/
(12 VDC +/
(10 VDC +/
10%, 80 mA) (See note 1.)
5%, 100 mA) (See note 1.)
10%, 80 mA) (See note 2.)
5%, 100 mA) (See note 2.)
10%, 80 mA) (See note 2.)
5%, 100 mA) (See note 2.)
10%, 80 mA) (See note 2.)
5%, 100 mA) (See note 2.)
10%, 80 mA) (See note 2.)
5%, 100 mA) (See note 2.)
20 mA) + Sensor power supply
20 mA) + Sensor power supply
5 V, 0 to 10 V) + Sensor power supply
5 V, 0 to 10 V) + Sensor power supply
K3HB-H
10%, 80 mA)
5%, 100 mA)
B-21