IMI04160 Red Lion Controls, IMI04160 Datasheet

no-image

IMI04160

Manufacturer Part Number
IMI04160
Description
PNL METER DIGITAL 115/230VAC
Manufacturer
Red Lion Controls
Series
IMIr
Type
Rate Meterr
Datasheet

Specifications of IMI04160

Measuring Range
0 ~ 50kHz
Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.80" L x 1.95" W (96.5 x 49.5mm)
Display Digits
6
Display Digits - Height
0.560" (14.22mm)
Backlight
Without
Mounting Type
Panel Mount
Termination
Terminal Block
Voltage - Supply
115/230VAC
Lead Free Status / RoHS Status
Vendor undefined / Vendor undefined
Other names
Q4248729
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL IMI - APOLLO 6 DIGIT INTELLIGENT METER FOR RATE INPUTS
GENERAL DESCRIPTION
frequencies up to 50 KHz which can be scaled to any desired engineering units.
The sensor input is user configurable and allows for a wide selection of
compatible sensors. The adjustable minimum and maximum update times
provide optimal display response at any input frequency.
indicate the input rate and then be toggled to display either totalization or
efficiency. The max. display for all functions is 999,999. The totalizer features
independent scaling and a low signal cut-out to suit a variety of applications.
The efficiency feature can display the input rate in percent of target (process
efficiency). Additionally, nine segments can easily be programmed to linearize
transducers with non-linear outputs, such as square law devices.
display, which greatly simplifies initial set-up. English-style display prompts
and front panel buttons aid the operator in set-up and operation. A front panel
programmable lock-out menu used with the program disable input protects set-
up data and guarantees no unwanted changes occur during operation.
Programmable digital filtering enhances the stability of the reading.
Programmable remote inputs “E1-CON” and “E2-CON” can be used to control
a variety of functions, such as totalizing, alarm control, display hold or triggered
input. All set-up data is stored in nonvolatile memory.
controlled by either the front panel buttons or a remote input. The Peak/Valley
buffers can be assigned to either the rate or efficiency display and all readings
are retained at power-down.
programmable to operate in a wide variety of modes to suit many control or
alarm applications.
provides computer and printer interfacing to extend the capabilities of the
indicator. More than one unit can be connected in the loop with other RLC
products which have serial communications capabilities.
user to interface with a host of recorders, indicators and controllers. The
indicator has several built-in diagnostic functions to alert operators of most
malfunctions. Extensive testing of noise interference mechanisms and full burn-
DIMENSIONS In inches (mm)
EFFICIENCY
The Apollo Intelligent Meter for Digital Rate Inputs (IMI) accepts
The IMI provides two display functions in a single package. The display can
The indicator features a choice of two different scaling procedures for the rate
Peak/valley (max/min) indication is included and is easily recalled and
Optional dual relays that operate in parallel with solid state outputs are fully
The optional 20 mA current loop, half-duplex serial communications,
An optional 4 to 20 mA or 0 to 10 VDC analog output can be scaled by the
ACCEPTS INPUT RATES UP TO 50 KHz
6-DIGIT, 0.56" (14.2 mm) HIGH RED LED DISPLAY
SECONDARY DISPLAY INDICATES TOTALIZATION or
0.01% ACCURACY
PEAK/VALLEY INDICATION & MEMORY
PROGRAMMABLE FRONT PANEL LOCK-OUT
SENSOR EXCITATION SUPPLY
DUAL ALARM RELAY OUTPUTS (Optional)
BI-DIRECTIONAL SERIAL COMMUNICATIONS (Optional)
Note: Recommended minimum clearance (behind the panel) for mounting
clip installation is 2.1" (53.3)H x 5.5" (140)W.
1
in make the indicator extremely reliable in industrial environments. The die-cast
front bezel meets NEMA 4/IP65 requirements for washdown applications, when
properly installed. Plug-in style terminal blocks simplify installation and wiring
change-outs.
SAFETY SUMMARY
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
not equipped with safeguards. To do so, can be potentially harmful to persons
or equipment in the event of a fault to the unit.
SPECIFICATIONS
1. DISPLAY: 6-digit, 0.56" (14.2 mm) High Red LED, programmable decimal
2. POWER REQUIREMENTS:
3. CONTROLS: Three front panel push buttons for modifying alarm values
4. SIGNAL INPUT: Switch selectable to accept signals from a wide variety of
All safety related regulations, local codes and instructions that appear in the
Do not use this unit to directly command motors, valves, or other actuators
points, maximum display 999,999. Flashing display during totalizer
overflow. “———” displayed during rate/efficiency display out of range.
A.C. Power: Switch selectable 115/230 VAC, ±10%, 50/60 Hz, 14 VA
and indicator set-up. Three external inputs; one for disabling the front panel,
two for programmable function inputs.
sensors.
Max. Input Frequency: 50 KHz, 50% Duty Cycle.
Max. Input Voltage & Current:
Input Impedance: With MAG. PKUP. & NPN O.C. switches OFF; 1 MΩ.
4 to 20 mA or 0 to 10 VDC ANALOG OUTPUT (Optional)
NEMA 4/IP65 SEALED METAL FRONT BEZEL
SWITCHES:
With NPN O.C. switch OFF; ±50 V peak, ±5 mA.
MAG PKUP: Connects a 0.1 µF input damping capacitor.
Sensitivity: 125 mV peak (typical @ 12 VDC)
Hysteresis: 30 mV
Input Impedance: 26.5 KΩ @ 60 Hz
Max. Input Voltage: ±50 V peak
PANEL CUT-OUT
Bulletin No. IMI-C
Drawing No. LP0325
Released 8/07

IMI04160 Summary of contents

Page 1

Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL IMI - APOLLO 6 DIGIT INTELLIGENT METER FOR RATE INPUTS 6-DIGIT, 0.56" (14.2 mm) HIGH RED LED DISPLAY ACCEPTS INPUT RATES KHz SECONDARY DISPLAY INDICATES TOTALIZATION or ...

Page 2

... Two loops are required for all hook-ups, a transmit loop and a receive loop. An internal 20 mA source is provided with the serial option. Additionally, multiple units and other Red Lion Controls instruments can be serially addressed, with a maximum address capability of 99 units. ...

Page 3

Alarm #1 can be made to track Alarm #2 by enabling alarm tracking. This is useful in alarm set-ups where a pre-warning control activates before a second alarm shuts off the process when tracking is programmed. Changing the shut- off ...

Page 4

... YES YES LIMITED WARRANTY Red Lion Controls BV Printerweg 3821 AD Amersfoort Tel +31 (0) 334 723 225 Fax +31 (0) 334 893 793 PART NUMBERS ANALOG 115/230 VAC OUTPUT NO IMI04160 NO IMI04161 NO IMI04162 IMI04163 IMI04167 VDC IMI04169 Red Lion Controls AP 31, Kaki Bukit Road 3, #06-04/05 TechLink ...