IMI04160 Red Lion Controls, IMI04160 Datasheet - Page 3

no-image

IMI04160

Manufacturer Part Number
IMI04160
Description
PNL METER DIGITAL 115/230VAC
Manufacturer
Red Lion Controls
Series
IMIr
Type
Rate Meterr
Datasheet

Specifications of IMI04160

Measuring Range
0 ~ 50kHz
Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.80" L x 1.95" W (96.5 x 49.5mm)
Display Digits
6
Display Digits - Height
0.560" (14.22mm)
Backlight
Without
Mounting Type
Panel Mount
Termination
Terminal Block
Voltage - Supply
115/230VAC
Lead Free Status / RoHS Status
Vendor undefined / Vendor undefined
Other names
Q4248729
useful in alarm set-ups where a pre-warning control activates before a second
alarm shuts off the process when tracking is programmed. Changing the shut-
off trip value (Alarm #2) automatically changes Alarm #1 so that the offset
between Alarm #2 and Alarm #1 remains the same.
ISOLATED RE-TRANSMITTED ANALOG
OUTPUT OPTION
4 to 20 mA
4 to 20 mA current to drive chart recorders, remote indicators and controllers.
PROGRAMMABLE FUNCTIONS
a short sequence of data entries. The front panel “UP” and “DOWN” buttons
(shown as “arrows” on the front panel) are used to change the data and set-ups,
while the “P” button is used to save or enter the data. After pressing “P”, the user
gains entry into the programming mode. The programming modules are
identified by the message “Pro” and a module number in the display. “UP” and
“DOWN” are used to select the desired programming module and “P” is used to
enter it. All of the subsequent programming steps follow the same procedure.
The rear terminal labeled “PGM.DIS.” must be inactive (ungrounded) to gain
access to programming. The following table lists the programming steps.
“Pro 0” - RETURN TO MEASUREMENT MODE
“Pro 1” - SCALE UNIT BY APPLYING SIGNAL
“Pro 2” - SCALE UNIT BY KEY-IN SIGNAL LEVEL
“Pro 3” - PROGRAM FUNCTIONS ACCESSIBLE WITH FRONT
“Pro 4” - PROGRAM DIGITAL FILTERING AND REMOTE INPUT
Alarm #1 can be made to track Alarm #2 by enabling alarm tracking. This is
The re-transmitted analog output option transmits a digitally programmable
Programming of the indicator is divided into modular steps. Each module is
“dSPHYS” -
“dSPbUF” -
“SELdSP” -
“E1-CON” -
“ENtHYS” -
“dECPNt” -
“dECPNt” -
PANEL LOCKOUT ENGAGED
(E1-CON & E2-CON) FUNCTION
“dSP AL” -
“SCALE” -
“SCALE” -
“ENt AL” -
“rStbUF” -
“Lo-udt” -
“Lo-udt” -
“dSP 1” -
“rAtE 1” -
“dSP 1” -
“rAtE 1” -
“Hi-udt” -
“Hi-udt” -
“rSt AL” -
“round” -
“round” -
“rSttOt” -
“FILter” -
“SEGt” -
“SEGt” -
10 -
12 -
11 -
0 -
1 -
2 -
3 -
0 -
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
9 -
Toggle display between input rate and total or effciency
Enter decimal point for scaled input display
Enter rounding factor and trailing zeros for scaled
input display
Enter low update time for rate display updates
Enter high update time for rate display updates
Enter display reading for scaling point #1
Apply rate value for scaling point #1
Enter decimal point for scaled display
Enter rounding factor and trailing zeros for scaled
display
Enter low update time for rate display updates
Enter high update time for rate display updates
Enter display reading for scaling point #1
Enter rate value for scaling point #1
Enable display alarms
Enable enter alarms
Enable display hysteresis
Enable enter hysteresis
Enable reset latched alarms
Enable display of peak/valley readings
Enable reset of peak/valley readings
Enable switching display between input and
total/efficiency
Enable reset total
Enter level of digital filtering
no digital filtering
normal level
increased level
maximum level
Enter function of remote input
Re-start measurement time for input
Reset total
Reset and gate totalizer
Gate totalizer
Display hold
Reset peak/valley
Reset peak and start peak indicator
Reset valley and start valley indicator
Reset latched alarms
Reset all alarms
Input rate functions as a triggered rate meter
Print request
*
*
*
*
3
The compliance is 10 VDC. Non-standard current ranges within the 4 to 20 mA
range can be supported by calculating the slope and intercept of the
display/output and calculating the required display values at 4 mA and 20 mA.
0 to 10 VDC
0 to 10 VDC output signal to drive chart recorders, remote indicators and
controllers. Non-standard voltage ranges within the 0 to 10 VDC range can be
supported by calculating the slope and intercept of the display/output and
calculating the required display values at 0 VDC and 10 VDC.
“Pro 5” - PROGRAM SECOND DISPLAY AS TOTALIZER OR
“Pro 6” - PROGRAM ALARMS
“Pro 7” - PROGRAM SERIAL COMMUNICATIONS
“Pro 8” - PROGRAM RE-TRANSMITTED ANALOG OUTPUT
“Pro 9” - FACTORY SERVICE OPERATIONS
✧ - Entire sequence for this modular step is not shown (see manual for further
*
- This sequence may be locked-out due to other programmed sequences.
The re-transmitted analog output option transmits a digitally programmable
details).
“E2-CON” < >
“ASNbUF” -
“SCLFAC” -
“OndEL1” -
“OFdEL1” -
“OndEL2” -
“OFdEL2” -
EFFICIENCY TOTALIZER
“dECPNt” -
“dECPNt” -
“dELAY1” -
“dELAY2” -
(Protected by access codes)
“AddrES” -
“100Pct” -
“LAtC-1” -
“LAtC-2” -
“ASN-1” -
“HYS-1” -
“ASN-2” -
“HYS-2” -
“tbASE” -
“AN-Lo” -
“Lo-cut” -
“AN-HI” -
“FULL” -
“Act-1” -
“Act-2” -
“bAud” -
“ASIN” -
“dISP” -
“dISP” -
“AL-1” -
“AL-2” -
“Print” -
“trAc” -
“0” -
“1” -
“2” -
“3” -
“4” -
“5” -
“6” -
“7” -
“8” -
“9” -
E2-CON has the same programmable functions as
E1-CON.
Select desired display (Total or Efficiency)
Enter decimal point for totalizer
Enter time base
0 - Divide by 1 (second)
1 - Divide by 60 (minute)
2 - Divide by 3600 (hour)
Enter multiplying scale factor
Enter low-signal cut out
Assign peak/valley buffers
Enter decimal point for efficiency
Enter value for desired 100 percent target value
Enable alarm value tracking
Enable display alarm annunciators
Enable alarm #1 latching
Enter alarm #1 trigger source (input or total/eff.)
Enter alarm #1 value
Enter hysteresis value for alarm #1
Enter alarm #1 action (high or low)
Enable delay ON action for alarm #1
Enable delay OFF action for alarm #1
(disabled if delay ON is selected)
Enter delay time value
Enable alarm #2 latching
Enter alarm #2 trigger source (input or total/eff.)
Enter alarm #2 value
Enter hysteresis value for alarm #2
Enter alarm #2 action (high or low)
Enable delay ON action for alarm #2
Enable delay OFF action for alarm #2
(disabled if delay ON is selected)
Enter delay time value
Enter baud rate
Enter loop address number (0-99)
Enter print function
rate
rate, peak, valley
rate, alarm 1, alarm 2
rate, alarm 1, alarm 2, hysteresis 1, hysteresis 2,
peak, valley
totalizer/efficiency
rate, totalizer/efficiency
rate, totalizer/efficiency, peak, valley
totalizer/efficiency, alarm 1, alarm 2
rate, totalizer/efficiency, alarm 1, alarm 2
rate, totalizer/efficiency, alarm 1, alarm 2, hysteresis 1,
hysteresis 2, peak, valley
Enable/Disable abbreviated printing
Select source of analog output (input or total/eff.)
Enter 4 mA or 0 VDC display value
Enter 20 mA or 10 VDC display value
EFFICIENCY
TOTALIZER
*
*