METER MAINTENANCE 2"RND 12-48VDC

3003R-67X-0001

Manufacturer Part Number
3003R-67X-0001
Description
METER MAINTENANCE 2"RND 12-48VDC
Manufacturer
Curtis Instruments Inc
Series
enGage™ II, 3000r
Type
Programmable Maintenance Monitor with Hour Meterr
Datasheet

Specifications of 3003R-67X-0001

Shape
Circular
Voltage Rating
12 ~ 48V
Display Type
LCD - 10 Segment Bar, 5 Digits
Operating Temperature
-40°C ~ 85°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
17631703-67X-0001
267-1033
1. Mount unit in standard SAE round cutout.
2. Connect supply voltage to pins indicated: (V+) pin
4, (V-) pin 8.
3. Connect pin 6, as appropriate for key switch, to
enable gauge display.
4. Connect pin 3 as appropriate to activate the hour
meter.
5. Connect pin 2 to a hidden enable switch.
6. Connect pin 7 to an audio, visual, horn, or other
warning device (load).
warning device is 0.5 Amps.
Installation Procedure
Caution: Max current draw on
Caution!
Bracket has been designed to remain secured to the
gauge upon proper installation. Once installed
correctly, attempts to remove bracket from gauge
may result in damage to the bracket.
Curtis enGage™ II instruments are mounted in a
52mm round cutout. Serrations on the barrel of the
gauge, combined with the mounting bracket
provided, insure fast and trouble free installation. To
insure proper installation, the 2 locking tabs on
either side of the inner diameter of the bracket
should aligned with the serrations on the barrel of
the gauge (see drawing above). Next, slide the
bracket over the barrel of the gauge and press it
firmly against back of panel. You should hear the tab
sliding over the serrations.
Curtis enGage™ II mates with an 8-pin AMP
connector (AMP pins P/N 770904-X FOR #18-24
AWG P/N 794821-1).
A preassembled mating connector kit (Curtis P/N
17631800-01) with crimp-connect terminated wires
(approx. 5 inches in length) is also available.
Maintenance
1.
2.
Function
Output and Warning LED
Due
RMB = Right Most LCD Bar
LMB = Left Most LCD Bar.
Installation
Activated
LMB
LED
KEY
Shut off
LMB
FET