SKY72302-21 Skyworks Solutions Inc, SKY72302-21 Datasheet - Page 16

no-image

SKY72302-21

Manufacturer Part Number
SKY72302-21
Description
IC SYNTHESIZER 6.1GHZ 28-EPTSSOP
Manufacturer
Skyworks Solutions Inc
Type
Fractional N Synthesizerr
Datasheet

Specifications of SKY72302-21

Pll
Yes
Input
Clock, Crystal
Output
Clock, Crystal
Number Of Circuits
1
Ratio - Input:output
2:2
Differential - Input:output
Yes/Yes
Frequency - Max
6.1GHz
Divider/multiplier
Yes/No
Voltage - Supply
2.7 V ~ 3.3 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
28-TSSOP Exposed Pad, 28-eTSSOP, 28-HTSSOP
Frequency-max
6.1GHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
863-1079-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SKY72302-21
Manufacturer:
SKYWORKS/思佳讯
Quantity:
20 000
DATA SHEET • SKY72302-21 FREQUENCY SYNTHESIZER
Table 5. SKY72302-21 Signal Descriptions (2 of 2)
Table 6. Absolute Maximum Ratings
Table 7. Recommended Operating Conditions
16
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This
Note 1: When power steering is enabled, the charge pump supply must be 4.5 V maximum.
Note 1: Associated pairs of power and ground pins must be decoupled using 0.1 F capacitors.
Note: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
Analog RF supplies
Digital supply
Charge pump supplies
Operating temperature (T
Maximum analog RF supply voltage
Maximum digital supply voltage
Maximum charge pump supply voltage
Storage temperature
Operating temperature
Pin #
20
21
22
23
24
25
26
27
28
parameters set at or below their nominal values. Exceeding any of the limits listed here may result in permanent damage to the device.
device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human
body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
CPout_aux
GNDcp_aux (Note 1)
Fvco_aux
Fvco_aux
VCCcml_aux
(Note 1)
GNDdigital (Note 1)
VCCdigital (Note 1)
Data
CS
Pin Name
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
September 9, 2009 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 101216L
A
)
Analog output
Power and ground
Input
Input
Power and ground
Power and ground
Power and ground
Digital input
Digital input
Parameter
Parameter
Type
Auxiliary charge pump output. The gain of the auxiliary charge pump phase detector is controlled by the
Phase Detector/Charge Pump Control Register.
Auxiliary charge pump ground.
Auxiliary VCO complimentary differential input.
Auxiliary VCO differential input.
ECL/CML, 3 V. Removing power safely powers down the associated divider chain and charge pump.
Digital ground.
Digital 3 V.
Serial address and data input pin. Address bits are followed by data bits.
Active low enable pin. Enables loading of address and data on the Data pin on the rising edge of Clock.
When CS goes high, data is transferred to the register indicated by the address. Subsequent clock edges
are ignored.
Min
–65
–40
Min
–40
2.7
2.7
2.7
Description
5.0 (Note 1)
+150
Max
5.25
Max
+85
+85
3.6
3.6
3.3
3.3
Units
Units
VDC
VDC
VDC
VDC
VDC
VDC
°C
°C
°C

Related parts for SKY72302-21