1-1761612-2 TE Connectivity, 1-1761612-2 Datasheet - Page 2

STEP-Z 12MM PLUG 104P

1-1761612-2

Manufacturer Part Number
1-1761612-2
Description
STEP-Z 12MM PLUG 104P
Manufacturer
TE Connectivity
Datasheets

Specifications of 1-1761612-2

Solder Ball
Tin-Lead
Product Height
12mm
Number Of Positions
104
Vacuum Cover
With
Contact Type
Tab
Contact Base Material
Copper Alloy
Contact Finish
Gold (30) over Nickel (50)
Connector Style
Plug
Housing Material
Thermoplastic - GF
Stack Height (mm [in])
17.00 [0.669], 23.00 [0.905], 27.00 [1.063]
Rohs/elv Compliance
ELV compliant, 5 of 6 Compliant
Lead Free Solder Processes
Reflow solder capable to 245°C
Packaging Method
Tray

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
1-1761612-2
Manufacturer:
TE Connectivity AMP Connectors
Quantity:
12 000
|
|
|
3.3.
3.4.
3.5.
Initial examination of product.
Final examination of product.
Low Level Contact Resistance
(LLCR).
Insulation resistance.
Rev B
Ratings
!
!
!
Performance and Test Description
Product is designed to meet the electrical, mechanical and environmental performance requirements
specified in Figure 1. Unless otherwise specified, all tests shall be performed at ambient environmental
conditions per EIA-364.
Test Requirements and Procedures Summary
Test Description
Voltage: 48 volts AC
Current: 1.0 ampere
Temperature: 0 to 100
/
C
Meets requirements of product
drawing.
Meets visual requirements.
20 milliohms for 15 mm mated
height;
23 milliohms for 18 mm mated
height;
24 milliohms for 20 mm mated
height;
28 milliohms for 25 mm mated
height;
31 milliohms for 28 mm mated
height;
32 milliohms for 30 mm mated
height;
36 milliohms for 35 mm mated
height.
40 milliohms for 40 mm mated
height.
)
With a minimum of 500 data points,
the following
3% maximum > 5 milliohms;
1% maximum > 10 milliohms;
0% > 50 milliohms.
5000 megohms minimum initial.
1000 megohms minimum final.
R 10 milliohms maximum.
Figure 1 (continued)
ELECTRICAL
Requirement
)
R shall apply:
EIA-364-18.
Visual and dimensional (C of C)
inspection per product drawing.
EIA-364-18.
Visual inspection.
EIA-364-23.
Subject specimens to 100
milliamperes maximum and 20
millivolts maximum open circuit
voltage.
See Figure 3.
EIA-364-21.
500 volts DC, 1 minute hold.
Test between 10 signal-signal pair
and 10 signal-to-adjacent ground
contacts of mated specimens.
Procedure
108-2143
2 of 8