STEP-Z 12MM PLUG 104P

1-1761612-2

Manufacturer Part Number
1-1761612-2
Description
STEP-Z 12MM PLUG 104P
Manufacturer
TE Connectivity
Datasheets

Specifications of 1-1761612-2

Solder Ball
Tin-Lead
Product Height
12mm
Number Of Positions
104
Vacuum Cover
With
Contact Type
Tab
Contact Base Material
Copper Alloy
Contact Finish
Gold (30) over Nickel (50)
Connector Style
Plug
Housing Material
Thermoplastic - GF
Stack Height (mm [in])
17.00 [0.669], 23.00 [0.905], 27.00 [1.063]
Rohs/elv Compliance
ELV compliant, 5 of 6 Compliant
Lead Free Solder Processes
Reflow solder capable to 245°C
Packaging Method
Tray

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
1-1761612-2
Manufacturer:
TE Connectivity AMP Connectors
Quantity:
12 000
Disturbed interface.
Temperature cycling.
Humidity-temperature cycling.
High temperature life.
Thermal shock.
Rev B
Test Description
See Note.
Any measured resistance
exceeding 100% increase in total
resistance from initial value
recorded at hot temperature, shall
be considered an open. An open
followed by 10 additional opens
shall be considered a failure. The
time to failure shall be recorded as
the first open cycle of the failure
sequence.
See Note.
See Note.
See Note.
No discontinuities of 1 microsecond
or longer duration.
See Note.
Figure 1 (continued)
ENVIRONMENTAL
Requirement
Interface shall be disturbed so that
contact surfaces move about 0.10
mm or less.
Subject specimens to temperature
range between 0 and 100 ± 5
Temperature ramp shall be < 20
per minute (<10
preferred). Dwell at each
temperature extreme for a minimum
of 15 minutes after printed circuit
board reaches temperature. Cycle
time shall be approximately 60
minutes (24 test cycles per day).
Specimens shall be tested until
63.2% of the specimens (18
connectors) have failed or until
2670 cycles have been completed.
EIA-364-31, Method III.
Subject mated specimens to 50
cycles (500 hours) between 25 and
65
ramp shall be 1 hour per transition
with 3 hour minimum dwell at 65
EIA-364-17, Method A, Test
Condition 3, Test Time Condition C.
Subject mated specimens to 85
for 500 hours.
EIA-364-32, Test Condition I.
Subject mated specimens to 5
cycles between -55 and 85
Temperature transfer rate shall be <
1 minute with 30 minute dwell at
each temperature extreme.
/
C at 95% RH. Temperature
Procedure
/
C per minute
108-2143
/
C .
/
C .
4 of 8
/
/
/
C
C .
C