M41T66Q6F STMicroelectronics, M41T66Q6F Datasheet - Page 18

no-image

M41T66Q6F

Manufacturer Part Number
M41T66Q6F
Description
IC RTC SERIAL W/ALARM 16-QFN
Manufacturer
STMicroelectronics
Type
Clock/Calendar/Alarmr
Datasheet

Specifications of M41T66Q6F

Memory Size
16B
Time Format
HH:MM:SS:hh (24 hr)
Date Format
YY-MM-DD-dd
Interface
I²C, 2-Wire Serial
Voltage - Supply
1.5 V ~ 4.4 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
16-QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-8377-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M41T66Q6F
Quantity:
18 000
Part Number:
M41T66Q6F
Manufacturer:
Maxim
Quantity:
178
Part Number:
M41T66Q6F
Manufacturer:
ST
0
Part Number:
M41T66Q6F
Manufacturer:
ST
Quantity:
20 000
Part Number:
M41T66Q6F ######
Manufacturer:
ST
0
Clock operation
3.3
Note:
18/33
Setting alarm clock registers
Address locations 0Ah-0Eh contain the alarm settings. The alarm can be configured to go
off at a prescribed time on a specific month, date, hour, minute, or second, or repeat every
year, month, day, hour, minute, or second. Bits RPT5–RPT1 put the alarm in the repeat
mode of operation.
default to the once per second mode to quickly alert the user of an incorrect alarm setting.
When the clock information matches the alarm clock settings based on the match criteria
defined by RPT5–RPT1, the AF (alarm flag) is set. If AFE (alarm flag enable) is also set, the
alarm condition activates the IRQ/OUT. To disable the alarm, write '0' to the alarm date
register and to RPT5–RPT1.
If the address pointer is allowed to increment to the flag register address, an alarm condition
will not cause the interrupt/flag to occur until the address pointer is moved to a different
address. It should also be noted that if the last address written is the “alarm seconds,” the
address pointer will increment to the flag address, causing this situation to occur.
The IRQ/OUT output is cleared by a READ to the flags register as shown in
subsequent READ of the flags register is necessary to see that the value of the alarm flag
has been reset to '0.'
Figure 13. Alarm interrupt reset waveform
Table 3.
RPT5
1
1
1
1
1
0
Alarm repeat modes
RPT4
1
1
1
1
0
0
Table 3
RPT3
shows the possible configurations. Codes not listed in the table
1
1
1
0
0
0
RPT2
1
1
0
0
0
0
RPT1
1
0
0
0
0
0
Once per second
Once per minute
Once per month
Alarm setting
Once per hour
Once per year
Once per day
Figure
M41T66
13. A