M41T66Q6F STMicroelectronics, M41T66Q6F Datasheet - Page 21

no-image

M41T66Q6F

Manufacturer Part Number
M41T66Q6F
Description
IC RTC SERIAL W/ALARM 16-QFN
Manufacturer
STMicroelectronics
Type
Clock/Calendar/Alarmr
Datasheet

Specifications of M41T66Q6F

Memory Size
16B
Time Format
HH:MM:SS:hh (24 hr)
Date Format
YY-MM-DD-dd
Interface
I²C, 2-Wire Serial
Voltage - Supply
1.5 V ~ 4.4 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
16-QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-8377-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M41T66Q6F
Quantity:
18 000
Part Number:
M41T66Q6F
Manufacturer:
Maxim
Quantity:
178
Part Number:
M41T66Q6F
Manufacturer:
ST
0
Part Number:
M41T66Q6F
Manufacturer:
ST
Quantity:
20 000
Part Number:
M41T66Q6F ######
Manufacturer:
ST
0
M41T66
3.7
Note:
3.8
Output driver pin
When the OFIE bit, AFE bit, and watchdog register are not set to generate an interrupt, the
IRQ/OUT pin becomes an output driver that reflects the contents of D7 of the calibration
register. In other words, when D7 (OUT bit) is a '0,' then the IRQ/OUT pin will be driven low.
The IRQ/OUT pin is an open drain which requires an external pull-up resistor.
Oscillator stop detection
If the oscillator fail (OF) bit is internally set to a '1,' this indicates that the oscillator has either
stopped, or was stopped for some period of time and can be used to judge the validity of the
clock and date data. This bit will be set to '1' any time the oscillator stops.
In the event the OF bit is found to be set to '1' at any time other than the initial power-up, the
STOP bit (ST) should be written to a '1,' then immediately reset to '0.' This will restart the
oscillator.
The following conditions can cause the OF bit to be set:
If the oscillator fail interrupt enable bit (OFIE) is set to a '1,' the IRQ/OUTpin will also be
activated. The IRQ/OUT output is cleared by resetting the OFIE or OF bit to '0' (NOT by
reading the flag register).
The OF bit will remain set to '1' until written to logic '0.' The oscillator must start and have
run for at least 1 second before attempting to reset the OF bit to '0.' If the trigger event
occurs during a power-down condition, this bit will be set correctly.
The first time power is applied (defaults to a '1' on power-up).
The voltage present on V
The ST bit is set to '1.'
External interference of the crystal
CC
or battery is insufficient to support oscillation.
Clock operation
21/33