CS5345-CQZ Cirrus Logic Inc, CS5345-CQZ Datasheet - Page 37

IC ADC AUD 104DB 200KHZ 48-LQFP

CS5345-CQZ

Manufacturer Part Number
CS5345-CQZ
Description
IC ADC AUD 104DB 200KHZ 48-LQFP
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CS5345-CQZ

Data Interface
Serial
Number Of Bits
24
Sampling Rate (per Second)
200k
Number Of Converters
2
Power Dissipation (max)
485mW
Voltage Supply Source
Analog and Digital
Operating Temperature
-10°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
48-LQFP
Resolution (bits)
24bit
Sampling Rate
192kSPS
Input Channel Type
Single Ended
Supply Voltage Range - Analog
3.13V To 5.25V
Supply Current
41mA
Digital Ic Case Style
QFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1780 - EVALUATION BOARD FOR CS5345
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
598-1083

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS5345-CQZ
Manufacturer:
QFP
Quantity:
513
Part Number:
CS5345-CQZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
CS5345-CQZ
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
CS5345-CQZR
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
DS658F2
7. PARAMETER DEFINITIONS
Dynamic Range
Total Harmonic Distortion + Noise
Frequency Response
Interchannel Isolation
Interchannel Gain Mismatch
Gain Drift
The ratio of the rms value of the signal to the rms sum of all other spectral components over the specified
bandwidth. Dynamic Range is a signal-to-noise ratio measurement over the specified bandwidth made with
a -60 dBFS signal. 60 dB is added to resulting measurement to refer the measurement to full scale. This
technique ensures that the distortion components are below the noise level and do not affect the measure-
ment. This measurement technique has been accepted by the Audio Engineering Society, AES17-1991,
and the Electronic Industries Association of Japan, EIAJ CP-307. Expressed in decibels.
The ratio of the rms value of the signal to the rms sum of all other spectral components over the specified
bandwidth (typically 10 Hz to 20 kHz), including distortion components. Expressed in decibels. Measured
at -1 and -20 dBFS as suggested in AES17-1991 Annex A.
A measure of the amplitude response variation from 10 Hz to 20 kHz relative to the amplitude response at
1 kHz. Units in decibels.
A measure of crosstalk between the left and right channels. Measured for each channel at the converter's
output with no signal to the input under test and a full-scale signal applied to the other channel. Units in deci-
bels.
The gain difference between left and right channels. Units in decibels.
The change in gain value with temperature. Units in ppm/°C.
CS5345
37

Related parts for CS5345-CQZ