STMPE321QTR STMicroelectronics, STMPE321QTR Datasheet - Page 7

IC CTLR TOUCH KEY 3CH 12-QFN

STMPE321QTR

Manufacturer Part Number
STMPE321QTR
Description
IC CTLR TOUCH KEY 3CH 12-QFN
Manufacturer
STMicroelectronics
Series
S-Touch™r
Type
Capacitiver
Datasheets

Specifications of STMPE321QTR

Number Of Inputs/keys
3 Key
Resolution (bits)
8 b
Data Interface
I²C
Data Rate/sampling Rate (sps, Bps)
100k
Voltage - Supply
1.65 V ~ 1.95 V
Mounting Type
Surface Mount
Package / Case
12-QFN
Voltage Supply Source
Single Supply
Resolution
7 bit to 10 bit
Interface Type
I2C
Supply Voltage (max)
1.95 V
Supply Voltage (min)
1.65 V
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating Temperature
-
Sampling Rate (per Second)
-
Lead Free Status / Rohs Status
 Details
Other names
497-8985-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STMPE321QTR
Manufacturer:
MICREL
Quantity:
54
STMPE321
2.1
Calibration algorithm
The STMPE321 maintains 2 parameters for each touch channel: TVR and CALIBRATED
IMPEDANCE. CALIBRATED IMPEDANCE is an internal reference which, if the currently
measured IMPEDANCE exceeds the CALIBRATED IMPEDANCE by a magnitude of TVR, is
considered a “TOUCH”.
If the IMPEDANCE is higher than the CALIBRATED IMPEDANCE, but the magnitude does
not exceed CALIBRATED IMPEDANCE by TVR, it is not considered a TOUCH. In this case,
2 scenarios are possible:
1. Environmental changes have caused the IMPEDANCE to increase
2. Finger is near the sensing pad, but not near enough
In case 1, the change in IMPEDANCE is expected to be small, as environmental changes
are normally gradual. A value "EVR" is maintained to specify the maximum IMPEDANCE
change that is still considered an environmental change.
Table 3.
‘IMP’ and ‘CALIBRATED IMP’ used in this table is not the direct register read-out.
IMP = 127 - impedance register readout
CALIBRATED IMP = 127 - calibrated impedance register readout.
The ETC WAIT register states a period of time for which all TOUCH inputs must remain "NO
TOUCH" for the next calibration to be carried out.
The CAL INTERVAL states the period of time between successive calibrations when there
are prolonged NO TOUCH conditions.
IMP>CALIBRATED IMP + TVR
IMP<CALIBRATED IMP + TVR
IMP>CALIBRATED IMP + EVR
IMP<CALIBRATED IMP + TVR
IMP<CALIBRATED IMP + EVR
IMP>CALIBRATED IMP
IMP>CALIBRATED IMP
IMP<CALIBRATED IMP
Calibration action under different scenarios
Scenario
Doc ID 15791 Rev 3
TOUCH,
no calibration
NO TOUCH,
no calibration
NO TOUCH,
new CALIBRATED IMP = previous CALIBRATED
IMP + change in IMP
CALIBRATED IMP + change in IMP
NO TOUCH,
new CALIBRATED IMP = new IMP
Touch sensing and calibration action
Capacitance compensation