Specifications of ISL23511WFB8Z-TK

Taps
32
Resistance (ohms)
10K
Number Of Circuits
1
Temperature Coefficient
80 ppm/°C Typical
Memory Type
Volatile
Interface
Pushbutton
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Resistance In Ohms
10K
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISL23511WFB8Z-TK
Manufacturer:
INTERSIL
Quantity:
1 001
Power-up and Power-down Requirements
There are no restrictions on the power-up or power-down
conditions of V
potentiometer pins provided that V
positive than or equal to V
The V
Pin Descriptions
R
The R
fixed terminals of a mechanical potentiometer. The minimum
voltage is V
R
relation to wiper movement direction.
R
The R
is equivalent to the movable terminal of a mechanical
potentiometer. The default wiper position at power-up is at
0 tap.
PU
The debounced PU input is used to increment the wiper
position. An on-chip pull-up holds the PU input HIGH. A
switch closure to ground or a LOW logic level will, after a
debounce time, move the wiper to the next adjacent higher
tap position.
PD
The debounced PD input is used to decrement the wiper
position. An on-chip pull-up holds the PD input HIGH. A
switch closure to ground or a LOW logic level will, after a
debounce time, move the wiper to the next adjacent lower
tap position.
Device Operation
There are three sections of the ISL23511: the input control,
the counter and decode section and the resistor array. The
input control section operates just like an up/down counter.
The output of this counter is decoded to turn on a single
electronic switch, connecting a point on the resistor array to
the wiper output. The resistor array is comprised of 31
individual resistors connected in series. At either end of the
array and between each resistor is an electronic switch that
transfers the potential at that point to the wiper.
The ISL23511 is designed to interface directly to two push
button switches for effectively moving the wiper up or down.
The PU and PD inputs increment or decrement a 5-bit
counter respectively. The output of this counter is decoded to
select one of the thirty-two wiper positions along the resistive
array. The wiper increment input, PU and the wiper
decrement input, PD are both connected to an internal
pull-up so that they normally remain HIGH. When pulled
LOW by an external push button switch or a logic LOW level
H
W
H
and R
and R
CC
H
W
and R
pin is the wiper terminal of the potentiometer which
ramp rate specification is always in effect.
L
L
references the relative position of the terminal in
SS
L
CC
and the maximum is V
pins of the ISL23511 are equivalent to the
and the voltages applied to the
RH
and V
8
CC
RL
CC
is always more
, i.e., V
. The terminology of
CC
≥ V
RH,
V
RL
.
ISL23511
input, the wiper will be switched to the next adjacent tap
position.
Internal debounce circuitry prevents inadvertent switching of
the wiper position if PU or PD remain LOW for less than
15ms, typical. Each of the buttons can be pushed either
once for a single increment/decrement or continuously for a
multiple increments/decrements. The number of
increments/decrements of the wiper position depend on how
long the button is being pushed. When making a continuous
push, after the first second, the increment/decrement speed
increases. For the first second, the device will be in the slow
scan mode. Then, if the button is held for longer than 1s, the
device will go into the fast scan mode. As soon as the button
is released, the ISL23511 will return to a stand-by condition.
If both PU and PD buttons are pulled low more than 15ms
from each other, all commands are ignored upon release of
ALL buttons.
The wiper, when at either fixed terminal, acts like its
mechanical equivalent and does not move beyond the last
position. That is, the counter does not wrap around when
clocked to either extreme.
Shutdown Mode
The ISL23511 enters into Shutdown Mode if both PU and PD
inputs are kept LOW for 2s. In this mode, the resistors array
is totally disconnected from its R
to the position closest to the R
Note that PU and PD inputs must be brought LOW within t
time window of 15ms (see “Shutdown Mode Timing” on
page 5) otherwise all commands will be ignored until both
inputs are released.
Holding either PU or PD input LOW for more than 15ms will
exit shutdown mode and return wiper to prior shutdown
position. If PU or PD will be held LOW for more than 250ms,
the ISL23511 will start auto-increment or auto-decrement of
wiper position.
R
The end-to-end resistance of the array will fluctuate once
V
CC
TOTAL
FIGURE 13. DCP CONNECTION IN SHUTDOWN MODE
is removed.
with V
CC
Removed
L
H
pin, as shown in Figure 13.
R
R
R
H
W
L
pin and the wiper is moved
January 21, 2008
FN6588.1
DB

Related parts for ISL23511WFB8Z-TK