F3SJ-A0645P30 Omron, F3SJ-A0645P30 Datasheet

no-image

F3SJ-A0645P30

Manufacturer Part Number
F3SJ-A0645P30
Description
F3SJ-A Safety Light Curtain, 30mm Resolution, 645 Mm Protected Height
Manufacturer
Omron
Datasheet
The updated F3SJ is even easier to use.
Features
Choose from two new tools for setting parameters and checking the system status.
"SD Manager" PC Setting Support Software
The "SD Manager" PC Setting Support Software helps reduce the time required for installing and troubleshooting the Safety Light Curtain.
The incident light level can be displayed in a bar
graph for each beam.
Setting Console
Note: The range of parameter setting and system status checking capabilities is different for the PC Setting Support Software and the Setting
● Beam alignment is easier.
• The lineup also includes models with S-mark certification.
• New models for body protection or presence detection.
Safety Light Curtain (Type 4)
F3SJ Ver.2
Console.
Be sure to read the “Safety Precautions” on page 65
and the “Precautions for All Safety Sensors” .
F39-JC@A Single-
end Connector
Cable or F39-JC@B
Double-end
Connector Cable
F39-JC@A Single-end
Connector Cable or
F39-JC@B Double-end
Connector Cable
Connector
The incident light level when the light emission of the
Safety Light Curtain is stopped is displayed in a bar
graph.
Branch
Branch
Connector
F3SJ
The ambient incident light
intensity can be checked.
F3SJ
Connection Cable
All parameters can be set and the system status can be checked
with a personal computer. In addition to making it easy to monitor
the beam alignment, the ambient incident light intensity can be
displayed in bar graph form for an easy check of the system status.
Connection Cable
To a USB terminal
F39-MC21
Setting Console for the F3SJ
When you don't want to carry a personal
computer onto the worksite, the Setting
Console is a handy way to set
parameters and check the system
status.
● The error log can be displayed.
The cause of the errors and countermeasures are
both displayed.
CSM_F3SJ_Ver2_DS_E_5_1
F39-GWUM
"SD Manager"
PC Setting
Support Software
1

Related parts for F3SJ-A0645P30

F3SJ-A0645P30 Summary of contents

Page 1

... Safety Light Curtain (Type 4) F3SJ Ver.2 The updated F3SJ is even easier to use. • The lineup also includes models with S-mark certification. • New models for body protection or presence detection. Be sure to read the “Safety Precautions” on page 65 and the “Precautions for All Safety Sensors” . ...

Page 2

... Floating blanking In this case, 2-beam floating blanking is set. If three or more beams are interrupted, the output goes OFF. A single sensor can also be divided Detection zone Warning zone F3SJ Ver.2 2 ...

Page 3

... Selecting a device is as easy as 1-2-3. The F3SJ Safety Light Curtain is a Type 4 safety sensor that can be used to configure a Category 4 safety circuit. This means that there is no need to worry about the safety of the resulting circuit. Use the following three easy steps to select the best model for your system design ...

Page 4

... F3SJ model Flexible cable with bending radius makes wiring a snap. The F3SJ cables (0.3 m) have M12 connectors and can be routed in any direction. Problems with connector compatibility have been eliminated. Free-directional cables can be routed down, back, left or right. The included standard mounting brackets are easier than ever to use ...

Page 5

... Total length: Approx (400 beams) Side-by-side Series Connection Cable (F39-JJR06L) Application example U-shaped configuration F3SJ Ver.2 Series connection cable long gap between end beams when connected side by side F39-LJ3 free-location mounting brackets can be mounted in any location, without getting in the way of the adjacent sensor. ...

Page 6

... A measure to prevent you from forgetting to connect a series connection cable. The connectors for series connection feature an intelligent design. To connect a series connection cable to the F3SJ, remove the Key Cap that is required when the sensor is used by itself. If you should happen to forget to connect the series connection cable, the sensor will not operate by itself without the Key Cap ...

Page 7

... Models with S-mark certification have an "-S" at the end of the model number. Example: F3SJ-A0245P14-S *2. Models with fixed auto reset (-TS). Parameters cannot be set using the F39-MC21 Setting Console or F39-GWUM "SD Manager" Setting Support Software for F3SJ. See the Ratings and Performance data for other differences between this and standard models. Safety Light Curtain Model List Products other than those listed below are also available ...

Page 8

... F3SJ-A2495P20 F3SJ-A2495N20 166 *1. The suffix "-TS" is attached to the model number of models with fixed auto reset. (Only for PNP output) *2. Protective Height (mm) = Total sensor length F3SJ-A25 Series (20-mm gap), F3SJ-A25-TS Series (20-mm gap) *1 Model Protective PNP output *1 Height (mm) *2 F3SJ-A0260P25 245 ...

Page 9

... F3SJ-A0395P30 F3SJ-A0395N30 16 F3SJ-A0420P30 F3SJ-A0420N30 17 F3SJ-A0445P30 F3SJ-A0445N30 18 F3SJ-A0470P30 F3SJ-A0470N30 19 F3SJ-A0495P30 F3SJ-A0495N30 20 F3SJ-A0520P30 F3SJ-A0520N30 21 F3SJ-A0545P30 F3SJ-A0545N30 22 F3SJ-A0570P30 F3SJ-A0570N30 23 F3SJ-A0595P30 F3SJ-A0595N30 24 F3SJ-A0620P30 F3SJ-A0620N30 25 F3SJ-A0645P30 F3SJ-A0645N30 26 F3SJ-A0670P30 F3SJ-A0670N30 27 F3SJ-A0695P30 F3SJ-A0695N30 28 F3SJ-A0720P30 F3SJ-A0720N30 29 F3SJ-A0745P30 F3SJ-A0745N30 30 F3SJ-A0770P30 F3SJ-A0770N30 31 F3SJ-A0795P30 F3SJ-A0795N30 32 F3SJ-A0820P30 F3SJ-A0820N30 33 F3SJ-A0845P30 F3SJ-A0845N30 34 F3SJ-A0870P30 F3SJ-A0870N30 35 F3SJ-A0895P30 ...

Page 10

... Water-resistant Case. Refer to page 14 for details. Specifications M12 connector (8-pin) Specifications M12 connector (8-pin) F39-JJR3K Cable length Model 0.3 m F39-JJR3W 0 F39-JC@B 0.06 m F39-JJR06L 0.15 m F39-JJR15L F3SJ Ver.2 Model F39-JCR5A F39-JC3A F39-JC7A F39-JC10A F39-JC15A F39-JC20A Model F39-JCR5B F39-JC1B F39-JC3B F39-JC5B F39-JC7B F39-JC10B F39-JC15B ...

Page 11

... Contacts G7S@-E Relays with Forcibly Guided Contacts Control unit (Can not be used as a muting system) (Dedicated PNP output type) * Appearance Output Relay, 3NO+1NC * F3SJ for NPN output type cannot be connected. Wire-saving Devices Type Appearance Connector Terminal Box/Muting Terminals *1 Safety Terminal Relays *2 *1 ...

Page 12

... Cable to connect top of the main unit and an off-the shelf external indicator (2-wire) Model F39-HJ@@@@ * Length (mm) 406 F39-MLG0406 610 F39-MLG0610 711 F39-MLG0711 914 F39-MLG0914 1,067 F39-MLG1067 32 1,219 F39-MLG1219 1,422 F39-MLG1422 1,626 F39-MLG1626 1,830 F39-MLG1830 2,134 F39-MLG2134 F3SJ Ver.2 Remarks Model F39-JJ3N Model 12 ...

Page 13

... For front mounting or side mounting. Mounting hole pitch 16 mm. Mounting bracket used when replacing F39-LJ11 existing area sensors having a mounting pitch with the F3SJ. Model Cap attaches to the main unit to enable muting function. F39-CN6 Attach it to either an emitter or a receiver. (Case: orange) F3SJ Ver ...

Page 14

... Note that the setting tools cannot be used with products shipped prior to December 2005. The setting tools cannot be used for setting parameters on the F3SJ-A@-TS series, but the monitoring function can be used. *2. This product is for use only with the F3SJ-A. It cannot be connected to conventional models of the F3SN-A series. Similarly, the F39-MC11 and F39-MT11 Dedicated Consoles for the F3SN-A cannot be connected to the F3SJ-A series. ...

Page 15

... F3SJ Ver.2 F3SJ-A@@@@P30 F3SJ-A@@@@P55 F3SJ-A@@@@N30 F3SJ-A@@@@N55 Opaque objects Opaque objects diameter diameter 100 270 to 2,470 mm 1 set ...

Page 16

... LED 3): ON based on the light intensity 3): Blink to indicate error details 1): ON when safety output is OFF, blinks at lockout. 1): ON while safety output is ON muting error indicator, Blanking /test indicator (green LED F3SJ Ver.2 F3SJ-A@@@@P30 F3SJ-A@@@@P55 F3SJ-A@@@@N30 F3SJ-A@@@@N55 ...

Page 17

... Test rod (*1), instruction manual, standard mounting bracket (F39-LJ1 bracket for top/bottom mounting), mounting brackets (intermediate) (*2), error mode label, User's Manual (CD-ROM) *1. The F3SJ-A@@@@@55 is not included. *2. Number of intermediate mounting brackets depends on protective height of F3SJ. Accessories For protective height from 600 to 1,130 mm: 1 set for each of the emitter and receiver is included ...

Page 18

... Blinks to indicate lockout. 2, orange LED 3): ON based on the light intensity 3): Blink to indicate error details 1): ON when safety output is OFF, blinks at lockout. 1): ON while safety output is ON muting error indicator, Test indicator (green LED F3SJ Ver.2 F3SJ-A@@@@P25-TS Opaque objects diameter 125 260 to 2,500 mm 1 set, 0260 to 1,600 max ...

Page 19

... Test rod, instruction manual, standard mounting bracket (F39-LJ1 bracket for top/bottom mounting), mounting brackets (intermediate) (*), error mode label, User's Manual (CD-ROM) * Number of intermediate mounting brackets depends on protective height of F3SJ. For protective height from 600 to 1,130 mm: 1 set for each of the emitter and receiver is included ...

Page 20

... Response time (OFF to ON): Response time calculated by the above x 5 (ms) Number of Beams Response time ms (ON to OFF) Response time ms (OFF to ON 108 17.5 116 to 140 20 148 to 172 22.5 180 110 17.5 120 to 140 20 150 to 166 22 112 17.5 113 to 125 20 100 17 F3SJ Ver 100 ...

Page 21

... Cable Extension Length Total cable extension length must be no greater than the lengths described below. When the F3SJ and an external power supply are directly connected, or when the F3SJ is connected to a G9SA-300-SC. Condition Using incandescent lamp for auxiliary output and external indicator output Not using incandescent lamp When connected to the F3SP-B1P ...

Page 22

... Horizontal direction Terminating end F3SJ Ver.2 F39-A01PY-PAC Yellow LED Indicator (yellow), Dedicated connector cable (0.1 m), Dedicated mounting brackets (1 for each) F3SJ-series Curtains with a protective height of 605 mm min. ° (operation and storage) Vertical direction only (see following diagram) Vertical direction Cable end ...

Page 23

... Connections Basic Connection for Basic System "Basic system" refers to the F3SJ with its default factory settings. The basic system provides basic safety light curtain functions. Most functions can be used without performing additional configuration. For PNP output (See page 24 for NPN output wiring.) ...

Page 24

... External test switch (connect the switch is not necessary.) S2: Interlock/lockout reset switch K1, K2: Relay or other device that controls hazardous parts of the machine K3, K4: Load or PLC, etc. (for monitoring) *1. Use a switch for micro loads (Input specifications mA). *2. F3SJ operates even when K3 and K4 are not connected ...

Page 25

... When using the interlock function, this also functions as an interlock reset switch. (Must be set with a setting tool.) *3. The F3SJ will operate even not connected. *4. Connect the muting lamp to either the external indicator output or auxiliary output 1 for the emitter or the receiver. When connecting the muting lamp to auxiliary output 1, the parameter must be changed with a setting tool ...

Page 26

... When using the interlock function, this also functions as an interlock reset switch. (Must be set with a setting tool.) *3. The F3SJ operates even when K3 is not connected. *4. Connect the muting lamp to either the external indicator output or auxiliary output 1 for the emitter or the receiver. When connecting the muting lamp to auxiliary output 1, the parameter must be changed with a setting tool ...

Page 27

... Pink Gray Receiver Main Circuit Receiver Main Circuit 1 4 Indication 7 F3SJ Ver.2 Brown +24 VDC Green Test input White Interlock selection input [Muting input 1] *1 Reset input Yellow Red Auxiliary output 2 [Muting input 2] *2 Blue Shield Brown Red External device monitoring input ...

Page 28

... Blue Communication Communication Red (6) Pink line (-) line (-) (7) Blue External device Auxiliary output 2 (8) Red monitoring input *2 F3SJ Ver.2 +24 VDC [Muting input 1] Reset input Auxiliary output 2 [Muting input 2] Shield Load Control output 2 Load Control output 1 Load Auxiliary output 1 External device monitoring input ...

Page 29

... This extension cable is used to connect to a terminal block controller F39-JC@A (e.g. F3SX, G9SA, G9SB, G9SX safety processing system (e.g. DeviceNet safety). This extension cable is used when the length of the connection cable F39-JC@B is insufficient, or when connecting to an F3SP-B1P controller. The length can be specified. F3SJ Ver.2 Description 29 ...

Page 30

... For basic system ON Indication status of LEVEL shows the light intensity level status of the F3SJ. Turns ON or blinks only on the sensor where the error occurred when the F3SJ enters lockout. The error mode indicators turn OFF on sensors (emitters or receivers) where an ON/ error did not occur other series-connected sensors. The indication status of Blinking ERROR shows the cause of the error ...

Page 31

... OFF Blinking Mutual interference or ambient incident light. Power supply voltage of F3SJ is out of the rated range. Insufficient current capacity of power supply. Incident light to blanking beams. Failure in communication line. Emitter and receiver have different F3SJ type names or number of series connections. Outside the effective range of parameters set by setting tool. ...

Page 32

... Safety-related Functions Interlock Function The F3SJ turns the safety outputs OFF when the power is turned ON or when a beam is interrupted, and maintains this state until a reset signal is applied. This state is called "interlock". You can reset this interlock by 2 methods; “auto reset that automatically turns safety output ON when an interrupting object is removed” ...

Page 33

... Other Functions Auxiliary Output (Non-safety output) The auxiliary output is used to monitor the status of the F3SJ. This output can be connected to a device such as a relay, indication lamp, programmable controller, etc. There are two auxiliary outputs: Auxiliary output 1 and auxiliary output 2. ...

Page 34

... Will the fixed blanking function be used? Will the floating blanking function be used? Will the detection distance be changed? Will other functions be used or changed? YES * F39-CN6 Key Cap for muting is required. F3SJ Ver.2 Basic system Basic system plus a setting tool for setting or changing parameters Muting system * Muting system * ...

Page 35

... C (protective height): 4-digit number in the table 6.5 dia. 13.75 2-Mounting holes See table below. 9 dia. Protective height 0245 to 0596 0600 to 1130 26 1136 to 1658 46 1660 to 2180 2195 to 2500 * Use E = 530 or less when none of the E values shown above are used. F3SJ Ver.2 (Unit: mm Number of intermediate brackets --- ...

Page 36

... 20 See table below. Protective height 0245 to 0596 0600 to 1130 1136 to 1658 1660 to 2180 2195 to 2500 * Use E = 530 or less when none of the E values shown above are used. 19 36.5 11 5.5 19.6 Material: Stainless steel F3SJ Ver.2 Mounting screw holes 4- Number of intermediate E * brackets 0 --- ...

Page 37

... Using Side Flat Mounting Bracket (F39-LJ2) 37.6 20 5.5 (17.25) 25 17.25 6.5 dia. 9 dia. 2 F39-LJ2 Material: Stainless steel Use standard brackets (Protective height) 5 0 F3SJ Ver.2 Mounting screw holes 4- Dimensions 39.5 4-digit number of the model C name (protective height) 37 ...

Page 38

... Using Free Location Mounting Bracket (F39-LJ3) Backside mounting F39-LJ3 Material: Zinc die-cast Side mounting F39-LJ3 Material: Zinc die-cast/stainless 5 (Protective height 5.5 C (Protective height F3SJ Ver.2 Mounting screw holes 6- Mounting screw holes 6- ...

Page 39

... The standard included intermediate mounting brackets are the same as the F39-LJ3 free-location mounting brackets. Purchase brackets as necessary if there are fewer intermediate mounting brackets than required. When intermediate mounting brackets are included, they can be used as free-location mounting brackets. Required number of F39-LJ3 free-location mounting brackets for 1 F3SJ set (emitter/receiver) (2 pieces are included with F39-LJ3) Number of included free location ...

Page 40

... For F3SN models with a protective height of 234 mm min. Add 11 to the F3SN's 4-digit number and apply it as the F3SJ's 4-digit number, and then replace with the standard brackets included with the product. [Selection example] F3SN-A0315P(N)14 becomes F3SJ-A0326P(N)14 (replace with standard brackets) Note: 1 ...

Page 41

... Material: Stainless steel brackets 30 Mounting screw holes 4-M5 (21. (Protective height 5.5 6.5 dia. 9 dia (Protective height) 19 11.5 44.9 30 F3SJ Ver Using M5 bolt, available range for mounting 20. Mounting screw holes 5.5 4-M5 (16. 16.5 20 Dimensions − 4-digit number of the model C name (protective height) 41 ...

Page 42

... C (Protective height) 6.5 dia. 5.8 32.5 32 15.5 4.2 9 dia. 19.9 Dimensions F3SJ Ver.2 Mounting screw holes 4- Dimensions 4-digit number of the model C name (protective height) Mounting screw holes 4- 4-digit number of the model name (protective height) 42 ...

Page 43

... For F3SN models with a protective height of 262 mm min. Subtract 17 from the F3SN's 4-digit number and apply it as the F3SJ's 4-digit number, and then replace with the standard brackets included with the product. [Selection example] F3SN-A0322P(N)25 becomes F3SJ-A0305P(N)20 (replace with standard brackets) Note: 1 ...

Page 44

... C (Protective B height) A 69.3 28 (17) 3 Note: Refer to the User's Manual (Cat. No. SCHG-718 and SCHG- 26 719) for the dimensions for side mounting. F3SJ Ver Mounting screw holes 5.5 5.5 4-M5 (16.65 16.65 20 Mounting screw holes 4- ...

Page 45

... F3W-C replacement correspondence table (F3W-C mounting holes can be used without modification) When replacing F3W-C@@@ with F3SJ-A@@@@@30 F3W-C Model Protective height F3W-C044 120 F3W-C084 280 F3W-C124 440 F3W-C164 600 F3W-C204 760 F3W-C244 920 * New holes must be drilled for the intermediate bracket. Using Top/Bottom Mounting Bracket C (F39-LJ11) ...

Page 46

... Standard length L Emitter Receiver 91 24-M3 5.9 7 × 5=35 13 max. 43 5.6 45 max. 2. dia. 20 173 90 9 dia. 6.5 dia F3SJ Ver dia. Waterproof connector 2 / Insulator diameter: 1.15 mm) Mounting screw holes 2-4.2 dia 84± 0.3 35± 5 0.3 111 max Material: Stainless steel 46 ...

Page 47

... Spatter Protection Cover F39-HJ@@@@ 32 Setting Support Software for the F3SJ F39-GWUM 3.6 0.7 Setting Console F39-MC21 10 Four digits in the model number (protective height) − 10 Material: polycarbonate (for the protective cover) (625.7) 67.9 35.8 Insulated vinyl round cable 4.6 dia. Standard length: 0 ...

Page 48

... Protective height 0245 to 0995 20 69 1001 to 2000 2009 to 2500 Note: For reference the dimension that will not interfere with the intermediate bracket on the Safety Light Curtain body. F3SJ Ver.2 Mounting screw holes When using M5 When using M6, M8 2-M8 4-M5 3.75 6.25 ...

Page 49

... C (protective height): 4-digit number in the table 74 46.5 Protective height 0245 to 0995 1001 to 2000 2009 to 2500 Note: For reference the dimension that will not interfere with the intermediate bracket on the Safety Light Curtain body. F3SJ Ver.2 Mounting screw holes When using M5 When using M6 2-M8 3.75 4-M5 ...

Page 50

... A B (Protective height 2-Mounting Brackets * 32 60.5 dia dia. 6.5 dia. 5 (Protective height) 22 2-Mounting Brackets * F3SJ Ver.2 Mounting screw holes When using M6, M8 When using M5 2-M8 8 4- The Mounting Brackets (F39-EJ-R) are sold separately. Mounting screw holes When using M5 ...

Page 51

... Connection Circuit Examples Examples of Safety Circuits For PNP output (See page 56 for NPN output wiring.) Wiring for single F3SJ application (category 4) • Use of welded relay contact detection and interlock is possible without a controller or relay unit. Emitter F39-JC@A-L KM3 +24 VDC Timing Chart Light incident ...

Page 52

... Interlock Test Reset Auxiliary selection output 1 OSSD1 OSSD2 External device monitoring T31 T32 14 F3SP-B1P KM1 KM1 KM2 F3SJ Ver.2 • Manual reset mode • Using external device monitoring function IN2 OUT KM3 KM1 KM2 KM2 S1: External test switch S2: Interlock/lockout reset switch ...

Page 53

... Note: 1. This wiring example is for category 4. 2. This example shows the connection when auxiliary output the standard setting (ON when light is interrupted). 3. When the F3SJ is series-connected more sets are connected to the total system of F3SX, power must be supplied to F3SJ from external source. For details, see instruction manual of F3SX. ...

Page 54

... A KM1, KM2: Magnetic contactor KM1 KM2 KM3: M: E1: PLC: F3SJ Ver.2 OUT KM3 KM1 KM2 M output 1 to T12 terminal and control output 2 to T23 directly. External test switch (connect the switch is not necessary.) Interlock reset switch Emergency stop switch (direct opening contacts) ...

Page 55

... KM3 KM4 S1: PLC, etc. S2: Motor controller KM1 to KM4: Magnetic contactor (operation command) M1, M2: E1: PLC: Wiring for manual reset mode OFF-delay time F3SJ Ver.2 Motor controller KM1 KM3 KM2 KM4 AND M1 M2 OFF External test switch (connect the switch is not necessary.) Lockout reset switch (connect the switch is not necessary ...

Page 56

... For NPN output (See page 51 for PNP output wiring.) Wiring for single F3SJ application (category 4) • Use of relay welded relay contact detection and interlock is possible without a controller or relay unit. Emitter F39-JC@A-L KM3 +24 VDC Timing Chart Light incident Light interrupted External test switch (S1) ...

Page 57

... Circuit KM1 KM2 F3SJ Ver.2 OUT KM3 KM1 KM2 M * emergency stop switch is not used, connect control output 1 to T12 terminal and control output 2 to T23 directly. S1: External test switch (connect the switch is not necessary.) S2: Interlock reset switch S3: Emergency stop switch (direct opening ...

Page 58

... E3Z-series, E2E-series (3-wire), E2VX-series, and D4N-series Sensors are recommended.) For an F3SJ model with PNP output, use a sensor with a 3-wire PNP transistor output contact output. For an F3SJ model with NPN output, use a sensor with a 3-wire NPN transistor output contact output ...

Page 59

... F3SJ incident Light incident/ Light Light interrupted interrupted ON Control output OFF * This value is the time when the F3SJ is used singly. When used in a series, this time is as shown in the table below. Number of Connected Units 1 0.15 Series of 2 0.26 Series of 3 0.29 Series ...

Page 60

... Example of a Safety Circuit with the Muting System For PNP output Wiring for muting function with single F3SJ application (category 4) When two muting sensors are connected • Attaching a keycap for muting (F39-CN6) enables the muting function to be used. Muting lamp (external indicator) ...

Page 61

... A1, B1, A2, B2, Muting sensor: Retro-reflective photoelectric sensor (E3Z-R81) KM3 KM1 KM2 M Timing Chart OUT Light incident Light interrupted A1 Control output B1 Control output A2 Control output B2 Control output Muting input 1 Muting input 2 F3SJ Control output PLC input * PLC output 61 ...

Page 62

... For NPN output Wiring for muting function with single F3SJ application (category 4) When two muting sensors are connected • Attaching a keycap for muting (F39-CN6) enables the muting function to be used. Emitter F39-JC@A-L Muting sensor (NPN output) Reflector Timing Chart Light incident ...

Page 63

... KM3 KM1 KM2 KM1 KM2 M Timing Chart OUT OUT Light incident Light interrupted A1 Control output B1 Control output A2 Control output B2 Control output Muting input 1 Muting input 2 F3SJ Control output KM1, KM2 N.O. contact KM1, KM2 N.C. contact PLC input * PLC output 63 ...

Page 64

... Connect the outer muting sensors A1 and A2 to muting input 1 and the inner muting sensors B1 and B2 to muting input 2. • When muting sensors A1 and then B1 (or A2 and then B2) turn ON in that order, the F3SJ will enter the muting state. A1, A2, B1, B2: Retro-reflective ...

Page 65

... Precautions for Safe Use Indication and meaning for safe use Meanings of Signal Words To ensure safe use of the F3SJ-A, signal words and an alert symbol are used in this catalog to indicate safety-related instructions. Because these instructions describe details very important to your safety extremely important that you understand and follow the instructions ...

Page 66

... Install the sensor system so that it is not affected by reflective surfaces. Failure may hinder detection, resulting in serious injury. When using more than 1 set of F3SJ, install them so that mutual interference does not occur, such as by configuring series connections or using physical barriers between adjacent sets. ...

Page 67

... Configure the system by using the optimal number of control outputs that satisfy the requirements of the necessary safety category. Do not connect each line of F3SJ power supply higher than 24 V+20%. Also, do not connect power supply. Failure may result in electric shock. For F3SJ to comply with IEC 61496-1 and UL 508, the DC power supply unit must satisfy all of the following conditions: • ...

Page 68

... F3SJ Versions Setting tools can be used with Version 2 and later versions of the F3SJ. The setting tools cannot be used with Version 1. The setting tools cannot be used even if a Version 1 F3SJ is combined in series with compatible F3SJ Units. (A communications error lockout will occur.) Unfortunately, the F3SJ's version cannot be upgraded. ...

Page 69

... Connect the F3SJ, Communications Unit, and personal computer as shown in the following diagram. The branch connector can be used on either the emitter side or receiver side. After the F3SJ has been wired, turn ON the power and start the Setting Support Software not possible to connect a branch connector because the connector is concealed by equipment or otherwise inaccessible, use the Special Cable with Plug to connect to the + and - communications lines ...

Page 70

... Calculate the safety distance to match the settings. After setting the fixed blanking function, you must verify that the F3SJ detects a test rod at any position in the entire area where intrusion must be detected. Failure may prevent detection of people and result in serious injury ...

Page 71

... When an F3SJ-A@14 is being used with an interrupting object that diameter, set three light beams as floating light beams. With this setting, the F3SJ's safety output will not turn OFF even if there is an interrupting object up to 22-mm wide in the floating blanking area. Effective Range vs. Number of Floating Light Beams ...

Page 72

... Setting a warning zone that does not include one of the outer light beams (figure 5) If Safety Light Curtains are connected in series, and at least one of an F3SJ's light beams is a normal light beam, all of a Light Curtain's light beams can be set as a warning zone (figure 3). Example Warning Zone Settings (Figures ...

Page 73

... Partial Muting (Muting area) Settings The light beams controlled by the muting function can be specified with a setting tool. (When the F3SJ is shipped, all light beams are set.) The light beams can be specified by teaching/recording the blocked light beams as muting light beams or manually specifying the desired light beams ...

Page 74

... Output Operation Modes (when allocated to an auxiliary output or external indicator output) Output operation mode (Output will the following situation.) Control output The control output is ON The F3SJ is ON and the received light intensity Light intensity diagnosis *1 is 100% to 130% of the threshold value for more than 10 seconds. Error/Lockout The F3SJ is in error or lockout status ...

Page 75

... Power cable length calculation function • Rated response time check function Ambient Light Intensity Indicator Summary It is possible to read the intensity of the light received by the F3SJ from ambient sources, such as other photoelectric sensors. Example Application Display the ambient light level while taking steps to reduce light interference form sources such as photoelectric switches in the area and neighboring F3SJ Units ...

Page 76

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords