F3SJ-A0745P30 Omron, F3SJ-A0745P30 Datasheet - Page 24

no-image

F3SJ-A0745P30

Manufacturer Part Number
F3SJ-A0745P30
Description
F3SJ-A Safety Light Curtain, 30mm Resolution, 745 Mm Protected Height
Manufacturer
Omron
Datasheet
For NPN output (See page 23 for PNP output wiring.)
Wiring when using manual reset mode, external device monitoring
Wiring for auto reset mode
• The auto reset mode will be enabled when the emitter is
*1. Use a switch for micro loads (Input
*2. F3SJ operates even when K4 is not connected.
S1:
S3:
K4:
wired as shown below.
specifications: 5 V, 1 mA).
External test switch (connect to 24 V if the switch is
not necessary.)
Lockout reset switch (connect to 0 V if the switch is
not necessary)
Load or PLC, etc. (for monitoring)
*2
*2
K4
K4
S1
*1
S1
*1
S2
*1
S3
*1
(Gray) Communication line (+)
Communication
line (−)
(Pink)
Communication line (+) (Gray)
Communication line (−) (Pink)
24 VDC
0 V
Power
supply
K1
K2
K3
*2
K1
(Gray) Communication line (+)
(Pink) Communication line (−)
Wiring when the external device monitoring function will not
be used
• Use a setting tool to set the external device monitoring function to
• When using an auxiliary output 1 that has not been changed (output
K2
"Disabled."
operation mode is "control output data," and inverse of control output
signals is "Enabled), the external device monitoring function will be
disabled when auxiliary output 1 and the external device monitoring input
are connected as shown below.
* The F3SJ operates even when K3 is not connected.
K1, K2: Relay or other device that controls hazardous
K3:
*1. Use a switch for micro loads (Input specifications: 5 V, 1 mA).
*2. F3SJ operates even when K3 and K4 are not connected.
When K3 is not necessary, connect auxiliary output 1
only to the external device monitoring input.
S1:
S2:
K1, K2: Relay or other device that controls hazardous parts of the machine
K3, K4: Load or PLC, etc. (for monitoring)
parts of the machine
Load or PLC, etc. (for monitoring)
External test switch (connect to 24 V if the switch is not necessary.)
Interlock/lockout reset switch
0 V
24 VDC
Power
supply
*
K3
K1
K2
F3SJ Ver.2
24 VDC
0 V
Power
supply
24