Indication Patterns and Intensity Levels of the Light Intensity Level
Indicators (LEVEL-1 to 5)
Note: Operation is possible with light intensity level of 100% or more, but to ensure stability, operate when at least 5 of the
Error Mode Indication Patterns and Cause of Errors (ERROR-A to C)
ON
OFF Blinking ON
OFF
indication lamps are ON.
1
A
2
3
B
4
C
5
170% or higher of control output ON level
From 130 to 170% of control output ON level
From 100 to 130% of control output ON level
From 75 to 100% of control output ON level
From 50 to 75% of control output ON level
Less than 50% of control output ON level
Mutual interference or ambient incident light.
Power supply voltage of F3SJ is out of the rated range. Insufficient current capacity of
power supply.
Incident light to blanking beams.
Failure in communication line.
Emitter and receiver have different F3SJ type names or number of series connections.
Outside the effective range of parameters set by setting tool.
Cap is not attached.
External device monitor failure.
Failure in interlock selection input line or reset input line.
Muting wiring failure.
Failure in control output wiring.
Failure in series connection cable wiring.
Failure in wiring of external display lamp output.
Failure in wiring of auxiliary output.
Broken series connection cable.
Wiring error or broken communications wire.
Influence of electrical noise, or failure in a series-connected F3SJ.
Light intensity level
Cause of error