6-Y-1-MF-120A EATON CUTLER HAMMER, 6-Y-1-MF-120A Datasheet - Page 118

Electromechanical Totalizing Counter

6-Y-1-MF-120A

Manufacturer Part Number
6-Y-1-MF-120A
Description
Electromechanical Totalizing Counter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of 6-Y-1-MF-120A

No. Of Digits / Alpha
6
Digit Height
4.8mm
Power Consumption
12W
Mounting Type
Base
Counter Supply Voltage
120VAC
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54.6
General Specifications, continued
Description
Relay/Transistor Outputs (Standard on Batch Controls, Optional on Totalizers)
Number
Relay contact type
Relay contact rating
Transistor type
OFF state block
ON state conduct
Max. switching frequency
Isolation dielectric strength
Optional Outputs
Analog retransmission
RS-485 serial communications
Environmental
Operating environment
Temperature
Vibration
Shock
EMC
Front panel
Agency approval
Pollution degree 2
118
Output signals
Accuracy
Isolation dielectric strength
Baud rate
Parity
Address range
Protocol
Isolation dielectric strength
Operating
Storage
Humidity
Control Products Catalog CA08102001E—August 2010 www.eaton.com
Counters, Panel Meters, Tachometers and Timers
Flow Totalizers, Transmitters and Controls
Specification
Two relays or one relay and one transistor
One set Form C per relay
5A, 250 Vac or 30 Vdc
NPN, opto isolated
30 Vdc max., 0.1 mA max. leakage current
50 mA max., 1.2 Vdc max. C-E drop
4 kHz (50-50 duty cycle)
2300 Vac
4–20 mA (<750 ohms) and 0–10V (>2500 ohms)
0.13% full scale and 100 PPM/°C (and 0.07% full scale change over 4–20 mA load ranges
2300 Vac to signal inputs, relays and AC power inputs; 500 Vac to analog outputs and
DC power inputs
1200, 2400, 4800, 9600, or 19,200, programmable
Even, odd or no parity
00 to 99 decimal (00 indicates off line)
Opto 22
2300 Vac to signal inputs, relays and AC power inputs; 500 Vac to analog outputs and
DC power inputs
Indoor use to 2000 meters
32 to 122°F (0 to 50°C)
–4 to 158°F (20 to 70°C)
0 to 85% RH, non-condensing
2.5 Gs, 30 to 200 Hz
30 Gs, 11 ms half sinewave
Immunity to EN 50082-2 (heavy industrial)
Emissions to EN 50081-2 (heavy industrial)
NEMA 4X when mounted with gasket provided
CE EMC immunity and emissions requirements were met using shielded wiring on the
RS-485, analog output and pulse input/power lines. The shields were connected to earth
ground at the Eclipse end of the shields.
Overvoltage Category II
®
compatible