6-Y-1-MF-120A EATON CUTLER HAMMER, 6-Y-1-MF-120A Datasheet - Page 127

Electromechanical Totalizing Counter

6-Y-1-MF-120A

Manufacturer Part Number
6-Y-1-MF-120A
Description
Electromechanical Totalizing Counter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of 6-Y-1-MF-120A

No. Of Digits / Alpha
6
Digit Height
4.8mm
Power Consumption
12W
Mounting Type
Base
Counter Supply Voltage
120VAC
Technical Data and Specifications
General Specifications
Description
Power
Power
Input
Resolution
Sampling rate
Temperature effect
Sensor lead resistance effect
Burn-out current
Common mode rejection ratio (CMRR)
Normal mode rejection ratio (NMRR)
Sensor break detection
Sensor break response time
Output
Relay rating
Pulsed voltage
Linear output
Alarm
Alarm relay
Alarm functions
Alarm mode
Dwell timer
Environmental and Physical
Operating temperature
Storage temperature
Humidity
Altitude
Pollution
Insulation resistance
Dielectric strength
Vibration resistance
Moldings
Dimensions
T/C
Three-wire RTD
Two-wire RTD
Resolution
Output regulation
Output setting time
Isolation breakdown voltage
Temperature effect
Counters, Panel Meters, Tachometers and Timers
Specification
90–250 Vac, 47–63 Hz, 10 VA (TC24), 12 VA (TC48/TC96), 5W maximum (TCxx4)
11–26 Vac/Vdc, 10 VA (TC24), 12 VA (TC48/TC96), 5W maximum (TCxx5)
18 bits
5 times/second
±1.5μV/ºC for all inputs except mV input
±3.0μV/ºC for mV input
0.2μV/ohm
2.6ºC/ohm of resistance difference of 2 leads
2.6ºC/ohm of resistance sum of 2 leads
200nA
120dB
55dB
Sensor open for TC, RTD and mV inputs, sensor short for RTD input, below 1 mA for
4–20 mA, below 0.25V for 1–5V input
Within 4 seconds for TC, RTD, and mV inputs; 0.1 second for 4–20 mA and 1–5V inputs
2A/240 Vac; 200,000 life cycles for resistive load
Source voltage 5V, current limiting resistance of 66 ohms
15 bits
0.02% for full load change
0.1 sec. (stable to 99.9%)
1000 Vac
±0.01% of SPAN/ºC
Form C rating; 2A/240 Vac; 200,000 life cycles for resistive load
Dwell timer, deviation high/low alarm, deviation band high/low alarm, PV high/low alarm
Normal, latching, hold, latching/hold
0.1 to 4553.6 minutes
14 to 122ºF (–10 to 50ºC)
–40 to 140ºF (–40 to 60ºC)
0–90% RH (non-condensing)
2000m max.
Degree 2
20 mohm min. (at 500 Vdc)
2000 Vac, 50/60 Hz for 1 minute
10–55 Hz, 10 m/s
Flame resistant polycarbonate
TC96 = 1.88 in (48 mm) (W) x 3.77 in (96 mm) (H) x 3.15 in (80 mm) (D)
TC48 = 1.88 in (48 mm) (W) x 1.88 in (48 mm) (H) x 4.56 in (116 mm) (D)
TC24 = 1.96 in (50 mm) (W) x 1.04 in (26.5 mm) (H) x 4.35 (110.5 mm) (D)
2
for 1 minute
Control Products Catalog CA08102001E—August 2010 www.eaton.com
Temperature Controls
54.8
127
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54
54