E2CY-V3A Omron, E2CY-V3A Datasheet - Page 5

no-image

E2CY-V3A

Manufacturer Part Number
E2CY-V3A
Description
Proximity Sensors NON-FERROUS PROX HEA D FLAT
Manufacturer
Omron
Series
E2CYr
Datasheets

Specifications of E2CY-V3A

Output Type
NPN
Proximity Sensor Sensing Distance
3mm
Proximity Sensor Sensing Distance Range
2 to 7mm
Mounting
Panel
Operating Temp Range
-10C to 55C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
10V
Operating Supply Voltage (typ)
12/15/18/24V
Operating Supply Voltage (max)
30V
Pin Count
3
Maximum Operating Temperature
+ 55 C
Operating Supply Voltage
10 V to 30 V
Sensing Distance
3 mm
Minimum Operating Temperature
- 10 C
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
-
Material - Body
Zinc Die-Cast
Shielding
Shielded
Voltage - Supply
-
Terminal Type
3-Wire
Package / Case
Box
Lead Free Status / Rohs Status
Supplier Unconfirmed
Teaching With and Without Target Object (Level Difference Detection)
Note: 1. The threshold level can be set to the same position by locating the target object at either one of the edges of the sensing range
E2CY
Step 1
Step 2
Step 3
2. After setting the mode to RUN, confirm that all eight excess gain level indicators are ON.
when performing steps 1 and 2.
Set the operation
mode selector to T.
Press the TEACH
button after locating
one of the sensing
levels in front of the
sensing surface.
Press the TEACH
button after locat-
ing the other sens-
ing level in front of
the sensing sur-
face.
If all the indicators
flash, repeat from
step 1. Or, change
the Sensor Head
position or set the
resolution selector
to FINE and then
repeat from step 1.
Set the operation
mode selector to
RUN.
Status of target object
Status of target object
Sensitivity setting
position
Sensing level difference
The ON point is set in the
middle of the two levels.
ON point
Sensing level
difference
Sensor Head
Sensor Head
Sensor Head
Control panel
Control panel
Control panel
Operation mode selector
TEACH button
TEACH button
Indicators
(Excess gain level indicators)
Indicators
(Excess gain level indicators)
Indicators
(Excess gain level indicators)
Sensor
Head side
ON
Sensor
Head side
OFF after the
indicators are
ON for 1 s.
Sensor
Head side
ON
OK
OK
OK
Sensor
Head side
Flashing
No good
E2CY
5