E2EX3D1N Omron, E2EX3D1N Datasheet

E2EX3D1N

Manufacturer Part Number
E2EX3D1N
Description
Manufacturer
Omron
Datasheet

Specifications of E2EX3D1N

Proximity Sensor Type
Inductive
Output Type
NPN/PNP
Proximity Sensor Sensing Distance
3mm
Proximity Sensor Sensing Distance Range
2 to 7mm
Proximity Sensor Switching Mode
NO
Mounting
Panel
Operating Temp Range
-25C to 70C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
10V
Operating Supply Voltage (typ)
12/15/18/24V
Operating Supply Voltage (max)
30V
Pin Count
4
Lead Free Status / Rohs Status
Compliant
A New Series of Easy-to-use
and Tough E2E/E2E2 Models
Long-size E2E2 Proximity Sen-
sor Conforms to CENELEC
• Ideal for a variety of applications.
• With a metal connector that can be tightened
• With an easy-to-see indicator, deeper mounting
• New 3-dia. size (sensing distance: 0.6 mm) added to
<READ AND UNDERSTAND THIS CATALOG>
Please read and understand this catalog before purchasing
the products. Please consult your OMRON representative if
you have any questions or comments.
Ordering Information
E2E
DC 2-wire/Pre-wired Models
Note 1. In addition to the above models, E2E-X@@15 models (e.g., E2E-X3D15-N), which are different in frequency from the above models, are
Yes
No
securely and a cable protector.
holes, and tightening flats for wrenches.
the lineup.
output function
Cylindrical Proximity Sensor
E2E/E2E2
Self-diagnostic
2. E2E models with a robotics cable are available as well. The model number of a model with a robotics cable has the suffix “-R”
3. Cables with a length of 5 m are also available. Specify the cable length at the end of the model number (e.g., E2E-X3D1-N 5M).
available.
(e.g., E2E-X3D1-R).
Shielded
Unshielded
Shielded
Unshielded
Size
M12
M18
M30
M12
M18
M30
M8
M12
M18
M30
M8
M12
M18
M30
3 mm
7 mm
10 mm
8 mm
14 mm
20 mm
2 mm
3 mm
7 mm
10 mm
4 mm
8 mm
14 mm
20 mm
Sensing distance
E2E-X3D1S (See note 1.)
E2E-X7D1S (See note 1.)
E2E-X10D1S (See note 1.)
E2E-X8MD1S (See note 1.)
E2E-X14MD1S (See note 1.)
E2E-X20MD1S (See note 1.)
E2E-X2D1-N (See notes 2 and 3.)
E2E-X3D1-N (See notes 1, 2 and 3.)
E2E-X7D1-N (See notes 1, 2 and 3.)
E2E-X10D1-N (See notes 1, 2 and 3.) E2E-X10D2-N
E2E-X4MD1 (See notes 2 and 3.)
E2E-X8MD1 (See notes 1, 2 and 3.)
E2E-X14MD1 (See notes 1, 2 and 3.)
E2E-X20MD1 (See notes 1, 2 and 3.
E2E/E2E2
NO
Cylindrical Proximity Sensor
Model
---
---
---
---
---
---
E2E-X2D2-N (See note 3.)
E2E-X3D2-N (See note 3.)
E2E-X7D2-N (See note 3.)
E2E-X4MD2
E2E-X8MD2
E2E-X14MD2
E2E-X20MD2
NC
1

Related parts for E2EX3D1N

E2EX3D1N Summary of contents

Page 1

... New 3-dia. size (sensing distance: 0.6 mm) added to the lineup. <READ AND UNDERSTAND THIS CATALOG> Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Ordering Information E2E DC 2-wire/Pre-wired Models ...

Page 2

... Note 1. A model with no polarity has a residual voltage which must be taken into consideration together with the interface condition (the PLC’s ON voltage, for example) when connecting the Proximity Sensor to a load. 2. The standard cable length is 300 mm. Models are also available with 500 mm and 1 m cables. ...

Page 3

... E2E-X2Y2 M18 E2E-X5Y1 (See notes 1 and 2.) NC E2E-X5Y2 M30 E2E-X10Y1 (See notes 1 and 2.) NC E2E-X10Y2 E2E-X2MY1 NC E2E-X2MY2 M12 E2E-X5MY1 (See notes 1 and 2.) NC E2E-X5MY2 M18 E2E-X10MY1 (See note 1.) NC E2E-X10MY2 M30 E2E-X18MY1 (See note 1.) NC E2E-X18MY2 Cylindrical Proximity Sensor Model Model 3 ...

Page 4

... NPN NC PNP NO PNP NC M8 Shielded M8 1.5 mm NPN NO NPN NC PNP NO PNP NC Un NPN NO shielded NPN NC PNP NO PNP NC E2E/E2E2 4 Cylindrical Proximity Sensor AC 2-wire/Connector Models Output Model E2E-X1R5E1-M1 Shielded M12 E2E-X1R5E2-M1 E2E-X1R5F1-M1 E2E-X1R5F2-M1 E2E-X2E1-M1 E2E-X2E2-M1 E2E-X2F1-M1 Un- E2E-X2F2-M1 shielded E2E-X5E1-M1 E2E-X5E2-M1 E2E-X5F1-M1 E2E-X5F2-M1 E2E-X10E1-M1 E2E-X10E2-M1 ...

Page 5

... Model E2E2-X3D1 E2E2-X3D2 E2E2-X7D1 E2E2-X7D2 E2E2-X10D1 E2E2-X10D2 E2E2-X8MD1 E2E2-X8MD2 E2E2-X14MD1 E2E2-X14MD2 E2E2-X20MD1 E2E2-X20MD2 Model E2E2-X2C1 E2E2-X2C2 E2E2-X2B1 E2E2-X2B2 E2E2-X5C1 E2E2-X5C2 E2E2-X5B1 E2E2-X5B2 E2E2-X10C1 E2E2-X10C2 E2E2-X10B1 E2E2-X10B2 E2E2-X5MC1 E2E2-X5MC2 E2E2-X5MB1 E2E2-X5MB2 E2E2-X10MC1 E2E2-X10MC2 E2E2-X10MB1 E2E2-X10MB2 E2E2-X18MC1 E2E2-X18MC2 E2E2-X18MB1 E2E2-X18MB2 Cylindrical Proximity Sensor 5 ...

Page 6

... AC 2-wire/Pre-wired Models Size Shielded M12 2 mm M18 5 mm M30 10 mm Unshielded M12 5 mm M18 10 mm M30 18 mm E2E/E2E2 6 Cylindrical Proximity Sensor Sensing distance Output configuration NPN NO NPN NC PNP NO PNP NC NPN NO NPN NC PNP NO PNP NC NPN NO NPN NC PNP NO PNP NC NPN NO NPN NC PNP NO PNP NC ...

Page 7

... AC 2-wire/Connector Models Size Shielded M12 2 mm M18 5 mm M30 10 mm Unshielded M12 5 mm M18 10 mm M30 18 mm Sensing distance Operation mode E2E/E2E2 Model E2E2-X2Y1-M4 E2E2-X2Y2-M4 E2E2-X5Y1-M4 E2E2-X5Y2-M4 E2E2-X10Y1-M4 E2E2-X10Y2-M4 E2E2-X5MY1-M4 E2E2-X5MY2-M4 E2E2-X10MY1-M4 E2E2-X10MY2-M4 E2E2-X18MY1-M4 E2E2-X18MY2-M4 Cylindrical Proximity Sensor 7 ...

Page 8

... The residual voltage of each E2E model with the model number suffix “-M1J-T” When connecting an E2E model with the suffix “- M1J-T” device, make sure that the device can withstand the residual voltage. 4. This OMRON in-house standard confirms resistance to cutting and other oils equivalent to the former JEM standard. E2E/E2E2 ...

Page 9

... When using an E2E with an M8 connector at an ambient temperature range between 70 ° C and 85 ° C, supply VDC to the E2E and make sure that the E2E has a control output of 100 mA maximum. 3. This OMRON in-house standard confirms resistance to cutting and other oils equivalent to the former JEM standard. M12 ...

Page 10

... Note 1. The response speed is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. 2. This OMRON in-house standard confirms resistance to cutting and other oils equivalent to the former JEM standard. E2E/E2E2 ...

Page 11

... Note 1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is over –25 ° When using an M18-or M30-sized E2E within an ambient temperature of 70 ° ° C, make sure that the E2E has a control output 200 mA max. 3. This OMRON in-house standard confirms resistance to cutting and other oils equivalent to the former JEM standard. M12 Unshielded ...

Page 12

... Power supply voltage waveform: Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset. 3. This OMRON in-house standard confirms resistance to cutting and other oils equivalent to the former JEM standard. E2E/E2E2 ...

Page 13

... The response speed is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. 3. This OMRON in-house standard confirms resistance to cutting and other oils equivalent to the former JEM standard. M12 ...

Page 14

... Note 1. The response speed is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance unsmoothed full-wave rectification power supply of 24 VDC ±20% (average value) can be used. 3. This OMRON in-house standard confirms resistance to cutting and other oils equivalent to the former JEM standard. E2E/E2E2 14 ...

Page 15

... Note 1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is –25 ° ° When using an M18-or M30-sized E2E2 within an ambient temperature of 70 ° ° C, make sure that the E2E2 has a control output 200 mA maximum. 3. This OMRON in-house standard confirms resistance to cutting and other oils equivalent to the former JEM standard. M12 Unshielded ...

Page 16

... E2E-X3 E2E- −20 −15 −10 − Distance Y (mm) Unshielded Models E2E-X@MD E2E-X20M 15 E2E-X14M E2E-X8M 5 E2E-X4M 0 −30 −20 − Distance Y (mm) E2E/E2E2 16 Cylindrical Proximity Sensor E2E-X@E@/F@ E2E-X@ −15 −10 − Distance Y (mm) E2E-X@ME@/F@ E2E-X@MY E2E-X18M 15 E2E-X10M 10 E2E-X5M E2E-X2M 5 0 −30 −20 − ...

Page 17

... VAC Residual output voltage Proximity Sensor Residual load voltage Load current (mA) E2E/E2E2 E2E-X@T1 DC/AC Supply voltage (V) 200 VAC Residual output voltage Proximity Sensor 100 VAC Residual load voltage OFF Load current (mA) Cylindrical Proximity Sensor AC power supply DC power supply 200 VAC OFF 17 ...

Page 18

... Copper Side length of sensing object d (mm) E2E-X14MD Iron Stainless steel (SUS304) Brass Aluminum Copper Side length of sensing object d (mm) E2E/E2E2 18 Cylindrical Proximity Sensor E2E-X3D@ E2E-X3T1 Iron Stainless steel (SUS304) Brass Aluminum Copper Side length of sensing object d (mm) E2E-X4MD Iron Stainless steel ...

Page 19

... E2E-X10Y@ Iron Stainless steel (SUS304 Aluminum Side length of sensing object d (mm) E2E-X10ME@/F@ E2E-X10MY Stainless steel (SUS304 Aluminum Side length of sensing object d (mm) E2E-CR8 Iron Stainless steel (SUS304) Brass Aluminum Copper 20 Side length of sensing object d (mm) Cylindrical Proximity Sensor Brass Iron Brass 19 ...

Page 20

... Distance Y (mm) Unshielded Models E2E2-X@MD E2E2-X20M 15 E2E2-X14M 10 Y E2E2-X8M −30 −20 − Distance Y (mm) Leakage Current (Typical) E2E2-X@D@ Supply voltage (V) E2E/E2E2 20 Cylindrical Proximity Sensor E2E2-X@C@/B@ E2E2-X@Y@ 3.0 2.5 Y 2.0 X E2E2-X2 1.5 1.0 0 -15 - Distance Y (mm) E2E2-X@MC@/B@ E2E2-X@MY ...

Page 21

... Brass Aluminum Copper Side length of sensing object d (mm) E2E/E2E2 200 VAC Residual output voltage Proximity Sensor 200 VAC Residual load voltage OFF Load current (mA) E2E2-X10D@ Iron Stainless steel (SUS304) Brass Aluminum Copper Side length of sensing object d (mm) Cylindrical Proximity Sensor 21 ...

Page 22

... Aluminum Side length of sensing object d (mm) E2E2-X5MC@/B@ E2E2-X5MY Iron Stainless steel (SUS304) Brass Aluminum Side length of sensing object d (mm) E2E/E2E2 22 Cylindrical Proximity Sensor E2E2-X14MD@ t=1 mm Iron Stainless steel (SUS304) Brass Aluminum Copper Side length of sensing object d (mm) E2E2-X5C@/B@ E2E2-X5Y Iron Stainless steel ...

Page 23

... Brown Load (0 V) Load Proximity sensor Orange (diagnostic main output) circuit Blue 3 Note: Connect both the loads to the +V side of the control output and diagnostic output. Brown 1 ** Black 4 (or 2)*** Load * 100 Ω Blue 3 Brown 1 Black 4 Load 100 Ω Blue Cylindrical Proximity Sensor ...

Page 24

... Blue 3 * Pin contact, and pin contact. E2E2-X@Y@ DC 2-wire Models Brown 2 Load Proximity sensor main circuit Blue 3 E2E/E2E2 24 Cylindrical Proximity Sensor E2E-X@T1 AC/DC 2-wire Models Brown 3 (or 1) Load Blue 4 (or 2) E2E2-X@B@ DC 3-wire Models + V Proximity sensor main circuit 100 Ω Pin contact, and pin contact. ...

Page 25

... PNP Output Operation indicator (red) Control output between black and blue lines Output voltage between black and blue lines E2E/E2E2 Sensing area Proximity Sensor ON Operation indicator (red) OFF ON Control output OFF Sensing Yes object No ON OFF ON OFF ON OFF Cylindrical Proximity Sensor 25 ...

Page 26

... OFF indicator (red) ON Control output OFF E2E2-X@Y@ AC 2-wire Models Yes Sensing object No ON Operation OFF indicator (red) ON Control output OFF E2E/E2E2 26 Cylindrical Proximity Sensor NC Models Non-sensing area Proximity Sensor Sensing object ON Setting indicator (green) OFF ON Operation indicator (red) OFF ON Control output ...

Page 27

... VDC Blue E2E/E2E2 E2E-X@D1-M1J-T DC 2-wire Models (No Polarity) E2E-X@Y@ AC 2-wire Models E2E-X@T1 AC/DC 2-wire Models Brown Load Power supply Blue Note: There is no need to be concerned about the polarity (Brown/Blue) of the Proximity Sensor. E2E-X@F@ DC 3-wire Models Brown Black Blue Cylindrical Proximity Sensor 27 ...

Page 28

... E2E2-X@Y@ AC 2-wire Models Brown Load Power supply Blue Note: The load can be connected as shown in the above diagrams. Connected to PC E2E2-X@D@ DC 2-wire Models Brown Blue 24 VDC E2E/E2E2 28 Cylindrical Proximity Sensor Brown Power supply Blue Load E2E2-X@C@ DC 3-wire Models Brown Black Blue 24 VDC ...

Page 29

... Note: Terminal 1 is not used. (Self-diagnostic output) Load Load Load Note: Terminals 2 and 3 are not used. Load Note: Terminals 3 and 4 are not used. E2E/E2E2 Pin arrangement Load or Load Load Load Load Note: Terminals 1 is not used. Load Load Cylindrical Proximity Sensor or 29 ...

Page 30

... E2E-X@E/F@-M@ DC 3-wire Models Connector Operation mode M12 E2E/E2E2 30 Cylindrical Proximity Sensor Applicable models E2E-X@E1-M1 Load E2E-X@F1-M1 Load E2E-X@E2-M1 Load E2E-X@F2-M1 Load E2E-X@E1-M3 Load E2E-X@F1-M3 Load E2E-X@E2-M3 Load E2E-X@F2-M3 Load Pin arrangement Note: Terminal 2 is not used. Note: Terminal 2 is not used. ...

Page 31

... Tighten the screw to a torque of 0.2 N·m maximum to secure the E2E-CR6, -CR8 and a torque of 0.4 N·m maximum to secure the E2E-C1. Part B Part A Part B Torque 12 N·m E2E/E2E2 Pin arrangement Load Load Pin arrangement Load Load Load E2E-CR6 E2E-CR8, -C1 hole No screw is provided with the E2E-CR6, -CR8 or E2E-C1. Cylindrical Proximity Sensor Load 31 ...

Page 32

... Model E2E-X@D@ Shielded DC 2-wire E2E-X@T1 AC/DC 2-wire E2E2-X@D@ DC 2-wire Unshielded E2E-X@E@ Shielded E2E-X@F@ DC 3-wire E2E-X@Y@ AC 2-wire E2E2-X@B@ E2E2-X@C@ Unshielded DC 3-wire E2E2-X@Y@ AC 2-wire Model E2E-X@C@ Shielded E2E-X@B@ E2E-C@C@ E2E-C@B@ DC 3-wire E2E/E2E2 32 Cylindrical Proximity Sensor d dia. Item 4 ...

Page 33

... E2E-X10Y@ E2E-X10T1 Unshielded E2E-X20MD@ E2E-X18ME@/F@ E2E-X18MY@ E2E2 Model M12 Shielded E2E2-X3D@ E2E2-X2C@/B@ E2E2-X2Y@ Unshielded E2E2-X8MD@ E2E2-X5MC@/B@ E2E2-X5MY@ M18 Shielded E2E2-X7D@ E2E2-X5C@/B@ E2E2-X5Y@ Unshielded E2E2-X14MD@ E2E2-X10MC@/B@ E2E2-X10MY@ M30 Shielded E2E2-X10D@ E2E2-X10C@/B@ E2E2-X10Y@ Unshielded E2E2-X20MD@ E2E2-X18MC@/B@ E2E2-X18MY@ Model No. Model No. E2E/E2E2 Cylindrical Proximity Sensor 33 ...

Page 34

... E2E-X@T1 Unshielded AC/DC 2-wire E2E2-X@D@ DC 2-wire E2E-X@E@ Shielded E2E-X@F@ DC 3-wire Unshielded E2E-X@Y@ AC 2-wire E2E2-X@B@ E2E2-X@C@ DC 3-wire E2E2-X@Y@ AC 2-wire Model E2E-X@B@ Shielded E2E-X@C@ E2E-C@B@ E2E-C@C@ DC 3-wire Note: Values in parentheses apply to Sensors operating at different frequencies. E2E/E2E2 34 Cylindrical Proximity Sensor B A Item Item 3 dia ...

Page 35

... Precautions for Correct Use Installation Power Reset Time The Proximity Sensor is ready to operate within 100 ms after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load. ...

Page 36

... Wiring High-tension Lines Wiring through Metal Conduit If there is a power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. Cable Tractive Force Do not pull on cables with tractive forces exceeding the following. ...

Page 37

... AND (serial connection) OR (parallel connection) AC 2-wire AND (serial connection) Example In this example, the above conditions are checked for when the PLC model is the C200H-ID212, the Proximity Sensor model is the E2E- X7D1-N, and the power supply voltage (14.4 V) ≤ (1.3 mA) ≥ OFF 3 ...

Page 38

... Proximity Sensor A, and when one of the sensing objects is close to Proximity Sensor B, Proximity Sensor B will not operate because the voltage imposed on Proximity Sensor which is too low. When Proximity Sensor A is OFF, the voltage imposed on Proximity Sensor B will reach the supply voltage and Proximity Sensor B will be ON. Then, ...

Page 39

... E2E/E2E2 AC 2-wire Figure Model No. Figure Model No. No. No. --- --- --- E2E-X1R5Y@ 7 E2E-X2Y@ 11 E2E-X3T1 E2E-X5Y@ 12 E2E-X7T1 E2E-X10Y@ 16 E2E-X10T1 15 E2E-X2MY@ 8 --- E2E-X5MY@ 12 E2E-X10MY@ 15 E2E-X18MY@ 17 --- --- --- E2E-X2Y@-M1 22 E2E-X5Y@-M1 24 E2E-X10Y@-M1 26 --- --- --- E2E-X5MY@-M1 23 E2E-X10MY@-M1 25 E2E-X18MY@-M1 27 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- Cylindrical Proximity Sensor AC/DC 2-wire Figure No. --- 12 13 --- --- --- --- --- --- --- 39 ...

Page 40

... E, F Models: diameter: 1.27 mm), Operation indicator (red) Standard length The cable can be extended (separate metal conduit 200 m (control output 100 m (diagnostic output). E2E/E2E2 40 Cylindrical Proximity Sensor Fig. 3: E2E-C1@@ 5.4 dia. Fig. 4: E2E-X1@@ 9.7 dia × 0 Insulator diameter: 1.05 mm), ...

Page 41

... Operation indicator (red), 2 conductors (D Models)/ setting indicator (green); 3 conductors (E Models) (Conductor Models: Operation indicator (red) cross section: 0.5 mm Insulator diameter: 1.74 mm), Standard length The cable can be extended (separate metal conduit 200 m (control output 100 m (diagnostic output). Cylindrical Proximity Sensor ...

Page 42

... M30 × 1.5 Two clamping nuts Toothed washer Note: D Models: Operation indicator (red), setting indicator (green Model: Operation indicator (red) E2E/E2E2 42 Cylindrical Proximity Sensor M12 Connector Models (Unshielded) Fig. 19: E2E-X4MD@-M1(G) E2E-X2ME@-M1/F@-M1 15 dia. M12 × Note: D Models: Operation indicator (red), setting indicator (green Model: Operation indicator (red) Fig ...

Page 43

... Two toothed washers Operating indicator M5 × 0 × 6.1 dia. M8 × 1 Indicator (See note.) Two clamping nuts Toothed washer M12 × 1 M12 × 1 4-dia. vinyl-insulated round cable, Standard length: 0.3 m M12 × 1 6-dia. vinyl-insulated round cable, Standard length: 0.3 m Cylindrical Proximity Sensor 43 ...

Page 44

... Fig. 35: E2E-X20MD1-M1GJ 42 dia. 36 Mounting Holes F Dimensions 3 dia. 4 dia. F (mm) +0.3 +0.5 3.3 / dia. 4 E2E/E2E2 44 Cylindrical Proximity Sensor 14.8 dia. Operation indicator (red), M18 × 1 setting indicator (green) Two clamping nuts Toothed washer Operation indicator (red), setting indicator (green) M30 × 1.5 ...

Page 45

... Indicator (See note.) M18 × 1 Two clamping nuts Toothed washer 6-dia. vinyl-insulated round cable with 2 conductors (D, Y Models)/3 conductors (B, C Models) (Conductor cross section: 0 Insulator diameter: 1.9 mm), Standard length The cable can be extended up to 200 m (separate metal conduit). Cylindrical Proximity Sensor 45 ...

Page 46

... M18 x 1 Two clamping nuts Toothed washer E2E2-X5Y@- dia M18 x 1 Two clamping nuts Toothed washer E2E/E2E2 46 Cylindrical Proximity Sensor Connector Models (Unshielded) E2E2-X5MC@-M1/B@-M1 21 dia. 17 M12 x 1 Operation indicator (red) E2E2-X5MY@-M4 21 dia. 17 1/2-20unf Operation indicator (red) E2E2-X10MC@-M1/B@-M1 ...

Page 47

... Operation indicator (red) M30 + 0.5 dia. 30.5 dia. 0 E2E/E2E2 M12 x 1 26.8 dia. Operation indicator (red) M30 x 1.5 Two clamping nuts Toothed washer 1/2-20unf 26.8 dia. Operation indicator (red) M30 x 1.5 Two clamping nuts Toothed washer Cylindrical Proximity Sensor 47 ...

Page 48

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords