BTS723GWT Infineon Technologies, BTS723GWT Datasheet

no-image

BTS723GWT

Manufacturer Part Number
BTS723GWT
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of BTS723GWT

Switch Type
High Side
Power Switch Family
BTS723GW
Input Voltage
42/-42V
Power Switch On Resistance
90mOhm
Output Current
2.5A
Number Of Outputs
Dual
Mounting
Surface Mount
Supply Current
2mA
Package Type
DSO
Operating Temperature (min)
-40C
Operating Temperature (max)
150C
Operating Temperature Classification
Automotive
Pin Count
14
Power Dissipation
3W
Lead Free Status / Rohs Status
Compliant
Smart High-Side Power Switch
Two Channels: 2 x 100m
Status Feedback
Suitable for 42V
Product Summary
General Description
Applications
Basic Functions
Protection Functions
Diagnostic Function
Infineon Technologies AG
Operating Voltage
On-state Resistance
Nominal load current
Current limitation
N channel vertical power MOSFET with charge pump, ground referenced CMOS compatible input and
diagnostic feedback, monolithically integrated in Smart SIPMOS 80V technology.
Providing embedded protective functions
An array of resistors is integrated in order to reduce the external components
µC compatible high-side power switch with diagnostic feedback for 12V and 24V and 42V grounded loads
All types of resistive, inductive and capacitive loads
Most suitable for inductive loads
Replaces electromechanical relays, fuses and discrete circuits
CMOS compatible input
Improved electromagnetic compatibility (EMC)
Fast demagnetization of inductive loads
Stable behaviour at undervoltage
Wide operating voltage range
Logic ground independent from load ground
Optimized inverscurrent capability
Short circuit protection
Overload protection
Current limitation
Thermal shutdown
Overvoltage protection (including load dump) with external
resistor
Reverse battery protection with external resistor
Loss of ground and loss of V
Electrostatic discharge protection (ESD)
Diagnostic feedback with open drain output and integrated
pull up resistors
Open load detection in OFF-state
Feedback of thermal shutdown in ON-state
Diagnostic feedback of both channels works properly in case of inverse current
Active channels One
V
R
I
I
L(NOM)
L(SCr)
bb(on)
ON
bb
protection
105m
2.9A
8A
7.0 ... 58V
1 of 15
Datasheet PROFET
two parallel
53m
4.2A
8A
Block Diagram
ST1
ST2
IN2
IN1
PROFET
Package
P-DSO-14
Status pull
up voltage
GND
Channel
Channel
Logic
Logic
1
2
BTS 723 GW
Vbb
Load 2
2003-Oct-01
OUT 2
OUT 1
Load 1

Related parts for BTS723GWT

BTS723GWT Summary of contents

Page 1

... Electrostatic discharge protection (ESD) Diagnostic Function Diagnostic feedback with open drain output and integrated pull up resistors Open load detection in OFF-state Feedback of thermal shutdown in ON-state Diagnostic feedback of both channels works properly in case of inverse current Infineon Technologies AG Datasheet PROFET 7.0 ... 58V bb(on) two parallel 105m 53m ON 2 ...

Page 2

... R = 20k equivalent to channel one Function and components of outputlogic equivalent to channel one 5 ST2 Status 2 Function see truthtable R = 850 Infineon Technologies AG ESD-protection Charge pump, level shifter, rectifier Gate protection Current limit Limit for unclamped inductive loads Open load detection Short circuit detection Temperature sensor ...

Page 3

... ST1 Diagnostic feedback 1,2 of channel 1,2 open drain 5 ST2 4 GND Logic Ground Connection for external pull up voltage source 11 SPU for the open drain status output. Pull up resistors are integrated. Infineon Technologies AG Pin configuration (top view IN1 ST1 GND ST2 IN2 BTS 723 GW ...

Page 4

... setup without the DUT connected to the generator per ISO 7637-1 and DIN 40839 Load dump ) 5 Device on 50mm*50mm*1.5mm epoxy PCB FR4 with 6cm connection. PCB is vertical without blown air. See page 15 Infineon Technologies AG = 25°C unless otherwise specified ...

Page 5

... Load Switching Capabilities and Characteristics On-state resistance ( OUT); each channel, two parallel channels, T see diagram, page Soldering point: Upper side of solder edge of device pin 15. See page 15 Infineon Technologies AG Symbol each channel: R thjs R one channel active: thja all channels active: Symbol each of the two channels ...

Page 6

... See timing diagram on page 13. ) Supply voltages higher than V 10 recommended. See also V ON(CL) ) Measured with load; for the whole device; all channels off not subject to production test, specified by design ) Add > Infineon Technologies AG Symbol each of the two channels one channel active: I L(NOM) 150° L(GNDhigh 90 ...

Page 7

... Please note, that in case of an inverse current no protection function is active. The power dissipation is higher compared to normal operation in forward mode due to the voltage drop across the drain-source diode ( with reverse polaritiy). If this mode lasts for a too long time the device can be destroyed. Infineon Technologies AG Symbol each of the two channels =-40° ...

Page 8

... Status output (open drain) Zener limit voltage Status low voltage 21 ) not subject to production test, specified by design 22 ) not subject to production test, specified by design ) If a ground resistor used, add the voltage drop across these resistors. GND Infineon Technologies AG Symbol each of the two channels L(off) V OUT(OL ...

Page 9

... Parallel switching of channel 1 and 2 is easily possible by connecting the inputs and outputs in parallel. In this mode it is recommended to use only one status. Terms IN1 V bb IN1 2 PROFET I ST1 Channel 1 ST1 ST1 GND IN1 Leadframe ( connected to pin 1,7,8,14 bb External R optional; a single resistor R GND operating voltage. Infineon Technologies AG Status 1 Status 2 level BTS 723 > 2. Leadframe ...

Page 10

... Short Circuit detection Fault Signal at ST-Pin: V > 4.0 V typ, no switch off by ON the PROFET itself, external switch off recommended! Short circuit Logic detection unit Infineon Technologies AG Inductive and overvoltage output clamp, IN1 or IN2 OUT1 or OUT2 clamped Overvolt. and reverse batt. protection ...

Page 11

... GND bb Any kind of load > GND IN IN(T+) Due to V > low signal available. GND ST Infineon Technologies AG V disconnect with energized inductive bb load OUT For inductive load currents up to the limits defined (max. ratings and diagram on page 12) each switch is L(OL) protected against loss Consider at your PCB layout that in the case of Vbb dis- connection with energized inductive load all the load current flows through the GND connection ...

Page 12

... While demagnetizing load inductance, the energy dissipated in PROFET with an approximate solution for R L · OUT(CL · L Maximum allowable load inductance for a single switch off (one channel j,start = 150° [mH] 1000 100 Infineon Technologies AG Typ. on-state resistance [mOhm Load 180 OUT 160 120 · i (t) dt, ON(CL · ...

Page 13

... V IN =high the device may not turn on (curve A) t approx. 150 s d(bb IN) Figure 2a: Switching a resistive load, turn-on/off time and slew rate definition OUT 90 dV/dton 10 Infineon Technologies AG Figure 2b: Switching an inductive load OUT Figure 3a: Short circuit: shut down by overtempertature, reset by cooling IN V OUT normal operation ...

Page 14

... Figure 4a: Overtemperature: Reset if T < OUT T J Figure 5a: Open load, : detection in OFF-state, open load occurs in off-state OUT I normal open typ. V > 2.7V L OUT Infineon Technologies AG Figure 6: Overvoltage, no shutdown OUT V OUT(OL OUT(OL) normal BTS 723 GW V ON(CL) 2003-Oct-01 t ...

Page 15

... Infineon Technologies Office. Infineon Technologies Components may only be used in life- support devices or systems with the express written approval of Infineon Technologies failure of such components can reasonably be expected to cause the failure of that life- support device or system affect the safety or thja effectiveness of that device or system ...

Related keywords