Specifications of EP3C25Q240C8N

Number Of Logic Elements/cells
24624
Number Of Labs/clbs
1539
Total Ram Bits
608256
Number Of I /o
148
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
240-MQFP, 240-PQFP
For Use With
544-2601 - KIT DEV CYCLONE III LS EP3CLS200544-2411 - KIT DEV NIOS II CYCLONE III ED.544-2370 - KIT STARTER CYCLONE III EP3C25
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Other names
544-2076
EP3C25Q240C8NES

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3C25Q240C8N
Manufacturer:
ALTERA
Quantity:
220
Part Number:
EP3C25Q240C8N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C25Q240C8N
Manufacturer:
WSI
Quantity:
780
Part Number:
EP3C25Q240C8N
Manufacturer:
ALTERA
0
Part Number:
EP3C25Q240C8N
Manufacturer:
ALTERA
Quantity:
100
Part Number:
EP3C25Q240C8N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Company:
Part Number:
EP3C25Q240C8N
Quantity:
1 400
Part Number:
EP3C25Q240C8NES
Manufacturer:
ALTERA
0
Electrical Characteristics
Operating Conditions
© December 2009
CIII52002-1.2
1
1
Altera Corporation
This chapter describes the electric characteristics, switching characteristics, and I/O
timing for Cyclone
The following sections provide information about the absolute maximum ratings,
recommended operating conditions, DC characteristics, and other specifications for
Cyclone III LS devices.
When Cyclone III LS devices are implemented in a system, they are rated according to
a set of defined parameters. To maintain the highest possible performance and
reliability of Cyclone III LS devices, you must consider the operating requirements in
this chapter. Cyclone III LS devices are offered in commercial and industrial grades.
Commercial devices are offered in –7 (fastest) and –8 speed grades. Industrial devices
are offered only in –7 speed grade.
In this chapter, a prefix associated with the operating temperature range is attached to
the speed grades—commercial with a “C” prefix; industrial with an “I” prefix. For
example, commercial devices are described as C7 and C8 per respective speed grades.
Industrial devices are described as I7.
Absolute Maximum Ratings
Absolute maximum ratings define the maximum operating conditions for
Cyclone III LS devices. The values are based on experiments conducted with the
device and theoretical modeling of breakdown and damage mechanisms. The
functional operation of the device is not implied at these conditions.
absolute maximum ratings for Cyclone III LS devices.
Conditions beyond those listed in
device. Additionally, device operation at the absolute maximum ratings for extended
periods of time may have adverse effects on the device. All parameters representing
voltages are measured with respect to ground.
Table 2–1. Cyclone III LS Devices Absolute Maximum Ratings
V
V
V
V
V
V
Symbol
C CINT
C CIO
C CA
C CD_P LL
C CB AT
I
Supply voltage for internal logic
Supply voltage for output buffers
Supply (analog) voltage for PLL regulator
Supply (digital) voltage for PLL
Battery back-up power supply for design
security volatile key register
DC input voltage
®
III LS devices. A glossary is also included for your reference.
Parameter
2. Cyclone III LS Device Data Sheet
Table 2–1
may cause permanent damage to the
(Note 1)
–0.5
–0.5
–0.5
–0.5
–0.5
–0.5
Min
Cyclone III Device Handbook, Volume 2
(Part 1 of 2)
Max
3.75
3.75
3.95
Table 2–1
1.8
3.9
1.8
lists the
Unit
V
V
V
V
V
V

Related parts for EP3C25Q240C8N