EP3C80F780C7 Altera, EP3C80F780C7 Datasheet - Page 14

IC CYCLONE III FPGA 80K 780FBGA

EP3C80F780C7

Manufacturer Part Number
EP3C80F780C7
Description
IC CYCLONE III FPGA 80K 780FBGA
Manufacturer
Altera
Series
Cyclone® IIIr

Specifications of EP3C80F780C7

Number Of Logic Elements/cells
81264
Number Of Labs/clbs
5079
Total Ram Bits
2810880
Number Of I /o
429
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
780-FBGA
For Use With
544-2601 - KIT DEV CYCLONE III LS EP3CLS200544-2411 - KIT DEV NIOS II CYCLONE III ED.
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Other names
544-2521

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3C80F780C7
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C80F780C7
Manufacturer:
ALTERA
0
Part Number:
EP3C80F780C7
Manufacturer:
ALTERA
Quantity:
300
Part Number:
EP3C80F780C7N
Manufacturer:
ALTERA
Quantity:
1 364
Part Number:
EP3C80F780C7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C80F780C7N
Manufacturer:
ALTERA
0
1–4
Table 1–3. Cyclone III Devices Recommended Operating Conditions
Cyclone III Device Handbook, Volume 2
V
V
V
V
V
V
C CINT
C CIO
C CA
C CD_P LL
I
O
Symbol
(3)
(3),
(3)
(3)
(4)
Supply voltage for internal logic
Supply voltage for output buffers, 3.3-V
operation
Supply voltage for output buffers, 3.0-V
operation
Supply voltage for output buffers, 2.5-V
operation
Supply voltage for output buffers, 1.8-V
operation
Supply voltage for output buffers, 1.5-V
operation
Supply voltage for output buffers, 1.2-V
operation
Supply (analog) voltage for PLL
regulator
Supply (digital) voltage for PLL
Input voltage
Output voltage
Figure 1–1
Figure 1–1. Cyclone III Devices Overshoot Duration
Recommended Operating Conditions
This section lists the functional operation limits for AC and DC parameters for
Cyclone III devices. The steady-state voltage and current values expected from
Cyclone III devices are provided in
without plateaus.
Parameter
shows the methodology to determine the overshoot duration.
4.2 V
4.1 V
3.3 V
ΔT
Table
Conditions
(Note 1)
1–3. All supplies must be strictly monotonic
T
,
(2)
(Part 1 of 2)
Chapter 1: Cyclone III Device Data Sheet
3.135
2.375
1.425
2.375
1.15
2.85
1.71
1.14
1.15
–0.5
Min
0
© January 2010 Altera Corporation
Typ
1.2
3.3
2.5
1.8
1.5
1.2
2.5
1.2
3
Electrical Characteristics
3.465
2.625
1.575
2.625
Max
1.25
3.15
1.89
1.26
1.25
V
3.6
CC IO
Unit
V
V
V
V
V
V
V
V
V
V
V

Related parts for EP3C80F780C7