EP1S40F780C7 Altera, EP1S40F780C7 Datasheet - Page 171

IC STRATIX FPGA 40K LE 780-FBGA

EP1S40F780C7

Manufacturer Part Number
EP1S40F780C7
Description
IC STRATIX FPGA 40K LE 780-FBGA
Manufacturer
Altera
Series
Stratix®r
Datasheet

Specifications of EP1S40F780C7

Number Of Logic Elements/cells
41250
Number Of Labs/clbs
4125
Total Ram Bits
3423744
Number Of I /o
615
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
780-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Other names
544-1429
EP1S40SF780C7

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1S40F780C7
Manufacturer:
ALTERA
Quantity:
355
Part Number:
EP1S40F780C7
Manufacturer:
ALTERA
Quantity:
648
Part Number:
EP1S40F780C7
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S40F780C7
Manufacturer:
XILINX
0
Part Number:
EP1S40F780C7
Manufacturer:
ALTERA
0
Part Number:
EP1S40F780C7
Manufacturer:
ALTERA
Quantity:
10
Part Number:
EP1S40F780C7
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP1S40F780C7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S40F780C7N
Manufacturer:
ALTERA
0
Operating
Conditions
Altera Corporation
January 2006
V
V
V
I
T
T
V
S51004-3.4
OUT
Table 4–1. Stratix Device Absolute Maximum Ratings
Table 4–2. Stratix Device Recommended Operating Conditions (Part 1 of 2)
Symbol
STG
J
CCINT
CCIO
I
CCINT
Symbol
Supply voltage
DC input voltage
DC output current, per pin
Storage temperature
Junction temperature
Supply voltage for internal
logic and input buffers
Parameter
Parameter
(3)
Stratix
Industrial devices are offered in -6 and -7 speed grades and commercial
devices are offered in -5 (fastest), -6, -7, and -8 speed grades. This section
specifies the operation conditions for operating junction temperature,
V
voltage specifications in this section are specified at the pins of the device
(and not the power supply). If the device operates outside these ranges,
then all DC and AC specifications are not guaranteed. Furthermore, the
reliability of the device may be affected. The timing parameters in this
chapter apply to both commercial and industrial temperature ranges
unless otherwise stated.
Tables 4–1
ratings.
CCINT
®
and V
devices are offered in both commercial and industrial grades.
through
With respect to ground
No bias
BGA packages under bias
CCIO
(4)
voltage levels, and input voltage requirements. The
4–8
Conditions
Conditions
provide information on absolute maximum
Notes
(1),
(2)
4. DC & Switching
Minimum
Minimum
1.425
–0.5
–0.5
–0.5
–25
–65
Characteristics
Maximum
Maximum
150
135
1.575
2.4
4.6
4.6
40
Unit
mA
°C
°C
Unit
V
V
V
V
4–1