JKXEP0G07FPSDP Souriau Connection Technology, JKXEP0G07FPSDP Datasheet - Page 6

Circular Push Pull Connectors PUSH-PULL CONNECTOR

JKXEP0G07FPSDP

Manufacturer Part Number
JKXEP0G07FPSDP
Description
Circular Push Pull Connectors PUSH-PULL CONNECTOR
Manufacturer
Souriau Connection Technology
Series
JKXr
Datasheet

Specifications of JKXEP0G07FPSDP

Product Type
Connectors
Number Of Contacts
7
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Contact will not seat in
connector, contact
backing out.
Bent solder contact
Connector will not
release from mating
part or operate
correctly
Over tightened the
back nut.
Collet will not grip
cable.
Connector will not
assemble.
Contact stubbing after
mating.
Electrical failure.
Leakage of seals
Rev 1 – April 14, 2004
Problem:
Wrong wire or insulation size, wrong
strip length, poor crimping, broken
clips, damaged insulator, removed
contact without proper removal tool,
bad crimp.
Bent in handling, bent in soldering
operation, connector assembled
incorrectly.
Pins and insulator were inserted into
electrical test while unprotected by
shell
Not using flats on latching sleeve and
back nut to torque connector,
improper assembly of the connector,
over mold material inside connector.
mating part or operate correctly,
damage connector.
Loose cable in connector.
Incorrect alignment of key in
connector, half bushings, connector
housing, insulator, collet, braid in key
slots in collet.
Bent contact and damaged contact,
connector-assembled incorrectly.
length, wire loading incorrect
location, poor solder joint.
Over torque of nut
Improper crimping, wrong wire strip
Connector will not release from
Trouble shooting
Cause:
Use correct wire, adjust strip length, strip
and re-crimp with new contact, replace
insulator, using wrong crimp tool, replace
contact.
Replace with new insert and/or contacts.
Release back nut and re-torque,
disassemble and reassemble, replace
connector.
Loosen back nut and retighten.
Check correct collet size is being used.
Disassemble connector and reassemble
connector-aligning keys, relocate braid in
collet.
Re-align contact, replace insert with
contacts.
Remove contact with correct removal
tool, reinstall new contact, and verify
strip length.
Disassemble connector and inspect seals.
Correction:

Related parts for JKXEP0G07FPSDP