EP3C120F484I7N Altera, EP3C120F484I7N Datasheet - Page 12

IC CYCLONE III FPGA 120K 484FBGA

EP3C120F484I7N

Manufacturer Part Number
EP3C120F484I7N
Description
IC CYCLONE III FPGA 120K 484FBGA
Manufacturer
Altera
Series
Cyclone® IIIr

Specifications of EP3C120F484I7N

Number Of Logic Elements/cells
119088
Number Of Labs/clbs
7443
Total Ram Bits
3981312
Number Of I /o
283
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
484-FBGA
For Use With
544-2589 - KIT DEV EMB CYCLONE III EDITION544-2566 - KIT DEV DSP CYCLONE III EDITION544-2444 - KIT DEV CYCLONE III EP3C120
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Other names
544-2538

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3C120F484I7N
Manufacturer:
DALLAS
Quantity:
101
Part Number:
EP3C120F484I7N
Manufacturer:
ALTERA
Quantity:
561
Part Number:
EP3C120F484I7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C120F484I7N
Manufacturer:
ALTERA
0
Part Number:
EP3C120F484I7N
Manufacturer:
ALTERA
Quantity:
150
Part Number:
EP3C120F484I7N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP3C120F484I7N
0
Part Number:
EP3C120F484I7N WWW.YIBEIIC.COM
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
1–2
Cyclone III Device Handbook, Volume 2
1
Table 1–1. Cyclone III Devices Absolute Maximum Ratings
Maximum Allowed Overshoot or Undershoot Voltage
During transitions, input signals may overshoot to the voltage listed in
undershoot to –2.0 V for a magnitude of currents less than 100 mA and for periods
shorter than 20 ns.
the duration of the overshoot voltage as a percentage over the lifetime of the device.
The maximum allowed overshoot duration is specified as percentage of high-time
over the lifetime of the device.
A DC signal is equivalent to 100% duty cycle. For example, a signal that overshoots to
4.2 V can only be at 4.2 V for 10.74% over the lifetime of the device; for device lifetime
of 10 years, this amounts to 10.74/10ths of a year.
I
V
V
T
T
Note to
(1) Supply voltage specifications apply to voltage readings taken at the device pins with respect to ground, not at the
OUT
S TG
J
Symbol
ES DHBM
ES DCDM
power supply.
Table
DC output current, per pin
Electrostatic discharge voltage using the human
body model
Electrostatic discharge voltage using the
charged device model
Storage temperature
Operating junction temperature
1–1:
Table 1–2
Parameter
lists the maximum allowed input overshoot voltage and
(Note 1)
Chapter 1: Cyclone III Device Data Sheet
Min
–25
–65
–40
© January 2010 Altera Corporation
(Part 2 of 2)
±2000
±500
Max
150
125
Electrical Characteristics
40
Table 1–2
Unit
mA
°C
°C
V
V
and

Related parts for EP3C120F484I7N