2864150 Phoenix Contact, 2864150 Datasheet

no-image

2864150

Manufacturer Part Number
2864150
Description
DIN Rail Terminal Blocks MINI MCR-SL-UIUI-NC 3 WAY ISOLATING AMP
Manufacturer
Phoenix Contact
Type
Wire to Wirer
Datasheets

Specifications of 2864150

Product
DIN Rail Terminal Blocks
Current Rating
50 mA
Voltage Rating
30 V
Mounting Style
DIN Rail
Termination Style
Screw
Height
93.1 mm
Length
102.5 mm
Width
6.2 mm
Wire Gauge Max (awg)
12
Wire Gauge Min (awg)
26
Phoenix Part Number
MINI MCR-SL-UI-UI-NC
Supply Voltage
19.2 to 30 VDC
Temperature Range
–20°C to +60°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
MCR-SL-UI-UI-NC MINI
MINI MCR-SL-UI-UI(-SP)
Configurable 3-Way Isolating Amplifier
Data Sheet
Product Description
The configurable 3-way isolating amplifier
MINI MCR-SL-UI-UI(-SP) is used to electrically iso-
late, condition, amplify, and filter analog signals.
On the input and output side, the standard signals
0...20 mA, 4...20 mA, 0...10 V, 2...10 V, 0...5 V or
1...5 V are available, electrically isolated.
The DIP switch accessible on the side of the housing
allows the configuration of the input and output signal
ranges.
The voltage supply (19.2...30 V DC) can either be pro-
vided via connecting terminal blocks "3"/"4" or "7"/"8"
of the modules, or together, via the DIN rail bus con-
nector (see Figure 5 on page 6). Please also observe
"Power Supply" on page 7.
101945_01_en
11/2004
Features
Figure 1
1
2
3
4
5
6
7
8
9
10 Universal snap-on foot for EN mounting rails
Input: Standard signals
Transparent cover
Potentiometer for adjustment
Groove for ZBF 6 Zack marker strip
Output: Standard signals
Supply voltage
Connection option for DIN rail bus connector
DIP switch S1
DIP switch S2
Features
1

Related parts for 2864150

2864150 Summary of contents

Page 1

MINI MCR-SL-UI-UI(-SP) Configurable 3-Way Isolating Amplifier Data Sheet Product Description The configurable 3-way isolating amplifier MINI MCR-SL-UI-UI(-SP) is used to electrically iso- late, condition, amplify, and filter analog signals. On the input and output side, the standard signals 0...20 mA, ...

Page 2

MINI MCR-SL-UI-UI(-SP) Technical Data General Data Supply voltage Current consumption Power consumption Transmission error With alignment Without alignment Temperature coefficient max. typ. Cut-off frequency Step response (10...90 %) Test voltage (input / output / supply) Ambient temperature range Operation Storage ...

Page 3

Input (see Figure 1, detail 1) Input signal range (configurable) Max. input signal Input resistance Output (see Figure 1, detail 5) Output signal range (configurable) Load Ripple Max. output signal Conformance With EMC Guideline 89/336/EEC And Low Voltage Directive 73/23/EEC ...

Page 4

MINI MCR-SL-UI-UI(-SP) Ordering Data Description Configurable 3-way isolating amplifier Screw terminal block, preconfigured (see "Data Type Key") Configurable 3-way isolating amplifier Screw terminal block, standard configuration (see "Standard Configuration" on page 7) Configurable 3-way isolating amplifier Spring-cage terminal block, preconfigured ...

Page 5

Screw Connection Figure 2 MINI MCR-SL-UI-UI MINI MCR-SL-UI-UI-NC Installation The device may only be installed and put into operation by qualified personnel. The corresponding national regulations (e.g. VDE, DIN) must be observed. The assignment of the connecting terminal blocks is ...

Page 6

MINI MCR-SL-UI-UI(-SP) Using DIN rail bus connector ME 6,2 TBUS-2 1,5/5-ST-3,81 GN (Order No Please also pay particular attention to the direction of the MINI Analog module and DIN rail bus connector when snapping into position: ...

Page 7

Power Supply Never connect the supply voltage directly to the DIN rail bus connector not permitted to draw power from the DIN rail bus connector or from individual MINI Analog modules! Feeding in power via the MINI Analog ...

Page 8

MINI MCR-SL-UI-UI(-SP) Configuration Table IN OUT 1 0...10 V 0...20 mA off 4...20 mA off 0... 2... 0... 1... 2...10 V 0...20 mA off 4...20 mA off 0... 2...10 V ...

Page 9

... DIP switches has been altered. The transmission error without adjust- ment is < 0.4%. Using the potentiometer, the error can be adjusted to < 0.1%. Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. PHOENIX CONTACT Inc. P.O. Box 4100 Harrisburg, PA 17111-0100 USA 717-944-1300 717-944-1625 www ...