SDV-FL4 DC100/110 Omron, SDV-FL4 DC100/110 Datasheet - Page 76

no-image

SDV-FL4 DC100/110

Manufacturer Part Number
SDV-FL4 DC100/110
Description
Sensor Hardware & Accessories VOLTAGE SENSOR
Manufacturer
Omron
Datasheets

Specifications of SDV-FL4 DC100/110

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Note: The impedance value is a reference value; actual values may vary.
Note: Overvoltage:
74
Allowable continuous
input overvoltage range
Input impedance
Control output
Power consumption
Ambient temperature
Control supply voltage
(see note)
Operating value
Setting error
Operating time
Influence of temperature
Influence of control power
Influence of frequency
(Input frequency changed
from 10 to 500 Hz for AC in-
put)
Influence of waveform
(For commercial frequency,
single-phase, full-wave AC
input)
Insulation resistance
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Weight
Ratings
Characteristics
Undervoltage: Operation when voltage is changed from 120% to 80% of the operating value.
Item
Item
Voltage Sensor
Operation when voltage is changed from 80% to 120% of the operating value.
1 k
SPDT
Rated load:5 A at 220 VAC (cos = 1),
Max. contact voltage:
Max. contact current:
Max. switching capacity:1,100 VA (cos = 1), 120 W (cos = 1),
DC: 5 W max.; AC: 5 VA max.
–10 C to 55 C (with no icing)
12, 24, 48, 100/110, 125, 200/220 VDC; DC operating voltage range: 80% to 130% of control power supply
100/110/120, 200/220/240 VAC (50/60 Hz); AC operating voltage range: 85% to 110% of control power supply
10 VDC
SDV-FL@
100% operation for voltage setting
0.5 s max. (see note)
0 C to 40 C:
(SDV-FL (operating value range: 4 to 12 mV)
–10 C to 0 C, 40 C to 55 C:
(SDV-FL (operating value range: 4 to 12 mV)
DC operating voltage range: 80% to 130%
AC operating voltage range: 85% to 110%
10 M min. (at 500 VDC) between the entire electric circuitry and external case, and between the input terminal
and power terminal
2,000 VAC for 1 min between the entire electric circuitry and external case, and between the input terminal and
power terminal
Destruction: 10 to 25 Hz, 2-mm double amplitude (2G max.) for 2 hrs each in 3 directions
Malfunction: 16.7 Hz, 1-mm double amplitude for 10 min each in 3 directions
Destruction: 294 m/s
Malfunction: 98 m/s
Approx. 290 g
2% of operating value
2% max. of operating value
4% max. of operating value)
4% max. of operating value
8% max. of operating value)
1% max. of operating value
1% max. of operating value
3% max. of operating value
1.2 x 50 s, 4,500 V between the entire electric circuitry and external case
1.2 x 50 s, 3,000 V between power terminals
SDV
5 A at 24 VDC (cos = 1),
2 A at 220 VAC (cos = 0.4),
2 A at 24 VDC (L/R = 7 ms)
SDV-F@@
150 VAC
50 k
150 VDC
250 VAC, 125 VDC
5 A
440 VA (cos = 0.4), 48 W (L/R = 7 ms)
SDV-FM@
2
2
(10G)
(30G)
Approx. 350 g
( 500 VDC for 1 min)
350 VAC
(500 VAC for 1 min)
2,500 k
350 VDC
SDV-FH@/FH@T
SDV-FH@T
150 VAC
50 k
SPST-NO and SPST-NC
150 VDC
0 C to 40 C:
–10 C to 0 C, 40 C to 55 C:
DC operating voltage range: 80% to 130%
AC operating voltage range: 85% to 110%
Approx. 310 g
2% of intermediate voltage of dead band,
1% of dead band voltage
2% max. of dead band voltage
4% max. of dead band voltage
1% max. of dead band voltage
1% max. of dead band voltage
3% max. of dead band voltage
SDV-DM@
SDV-D@@
( 500 VDC for 1 min)
350 VAC
(500 VAC for 1 min)
2,500 k
350 VDC
SDV-DH@