SDV-SH10 Omron, SDV-SH10 Datasheet

no-image

SDV-SH10

Manufacturer Part Number
SDV-SH10
Description
Sensor Hardware & Accessories SHUNT 10A
Manufacturer
Omron
Datasheet

Specifications of SDV-SH10

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Overvoltage/Undervoltage Monitoring
Relay for AC and DC Input
• Detect overvoltages or undervoltages (switch select-
• Detect undercurrent, reverse current, or overcurrent in
• Detect three-phase AC current for under and/or overcur-
• Available in 7 supply voltage configurations.
• Single-function model with ON-delay, OFF-delay, or star-
• Select either AC or DC voltage input.
• Polarity can be specified (SDV-FL) to enable easy re-
• Selectable reset value range from 2% to 30% of operat-
• LED operation indicator.
• UL/CSA approval (single-function models).
Model Number Structure
■ Model Number Legend
1. Voltage Sensor
2. Operation
3. Operating Voltage Range
4, 5. Control Power Supply Voltage
6. Timing Function (SDV-FH Only (See Note))
Note: SDV-FL and SDV-FM models can also be equipped with the
SDV-@@@@@
able) from 4 mV to 300 V.
DC circuits using shunt (SDV-FL).
rent using current converter.
tup lock settings (SDV-FH@T).
verse current detection.
ing value (SDV-F).
Voltage Sensor
SDV
1
F:
D:
L:
M:
H:
2:
3:
4:
5:
51:
6:
61:
7:
71:
None: Not provided
T:
timing function as a special specification. Ask your OMRON
representative for details.
2 3 4 5 6
Single-function (overvoltage or undervoltage detection)
Dual-function (overvoltage and undervoltage detection)
4 to 240 mV (DC input only) (For SDV-F only)
0.2 to 12 V (AC or DC input)
10 to 300 V (AC or DC input)
24 VDC
48 VDC
100/110 VDC
125 VDC
200/220 VDC (Single-function models)
100/110 VAC
120 VAC (Single-function models)
200/220 VAC
240 VAC (Single-function models)
Provided
Note: Not possible for the SDV equipped with the timing function
(SDV-FH@T).
CSM_SDV_DS_E_5_1
1

Related parts for SDV-SH10

SDV-SH10 Summary of contents

Page 1

... Timing Function (SDV-FH Only (See Note)) None: Not provided T: Provided Note: SDV-FL and SDV-FM models can also be equipped with the timing function as a special specification. Ask your OMRON representative for details. Note: Not possible for the SDV equipped with the timing function (SDV-FH@T). CSM_SDV_DS_E_5_1 1 ...

Page 2

... Input voltage range 0 SDV-DM2 SDV-DM3 SDV-DM4 SDV-DM5 SDV-DM6 SDV-DM7 SDV-DM71 SDV Rated voltage Model 60 mV SDV-SH75 SDV-SH100 SDV-SH150 SDV-SH200 SDV-SH300 SDV-SH500 SDV-SH750 SDV-SH1000 (selectable 300 V SDV-FH2 SDV-FH3 SDV-FH4 SDV-FH5 SDV-FH51 SDV-FH6 SDV-FH61 SDV-FH7 SDV-FH71 10 to 300 V SDV-DH2 SDV-DH3 SDV-DH4 SDV-DH5 SDV-DH6 SDV-DH7 SDV-DH71 ...

Page 3

... VAC SDV-FH61T 200/220 VAC SDV-FH7T 240 VAC SDV-FH71T Note: SDV-FL and SDV-FM models can also be equipped with the timing function as a special specification. Ask your OMRON representative for details. Specifications Single-function Models Overvoltage or Undervoltage Detection (Switch Selectable) Model Input voltage ...

Page 4

... Influence of control power DC operating voltage range: 80% to 130% AC operating voltage range: 85% to 110% ± ...

Page 5

... Voltage Multiplying undervoltage Factor Sticker detection for DC input. Location of DIP switch to set operating modes Note: The SDV-F@ is not equipped with a time setting knob. SDV-FH@T SDV-D@ Setting Intermediate Setting Operating Voltage of Dead Band Value Operation Indicator Setting Reset Value ...

Page 6

... Reset value value ON Output relay OFF Input Operating value Reset value Output relay Setting time Input Reset value Operating value Output relay ON OFF Setting time SDV Reset value Setting time Reset time (5 s min.) Reset value Setting time Reset time (5 s min.) 6 ...

Page 7

... Reset value Operating value Output relay ON OFF Reset time (5 s min.) Setting time Input Reset value Operating value ON Output relay OFF Reset time (5 s min.) Setting time ON Power OFF SDV Reset value Setting time Reset value Setting time Reset time (5 s min.) 7 ...

Page 8

... Set the DIP switch on the front panel for the required functions, operation inputs, and voltages. Set the switch to the top for ON settings and to the bottom for OFF settings. • Function (SDV-F): Set to either overvoltage or undervoltage detection. • Input: Set to either input. • Polarity (SDV-FL@ only): Set polarity or not to specify polarity. “8(+), 7(–)”: Use polarity as shown for pin number. “FREE”: Do not use polarity. ...

Page 9

... Accessory Labels OVER ×0.2 V INPUT DC OVER ×0.5 V INPUT AC UNDER ×1 V INPUT DC UNDER ×2 V ● INPUT AC ● ×4 V ● ● Accessory Labels OVER ×10 V INPUT DC OVER ×25 V INPUT AC UNDER ×50 V INPUT DC UNDER ×100 V ● INPUT AC ● ● SDV 9 ...

Page 10

... INPUT DC OVER& ×0.5 V UNDER INPUT AC ×1 V ×2 V ● ● ×4 V ● Accessory Labels OVER& ×10 V UNDER INPUT DC OVER& ×25 V UNDER INPUT AC ×50 V ● ×100 V ● SDV Accessory Labels OVER ×10 V INPUT DC OVER ×25 V INPUT AC UNDER ×50 V INPUT DC UNDER ×100 V INPUT AC 10 ...

Page 11

... Examples of Mode Setting Example 1 For the single-function SDV-FH6, the setting method given below would be used to detect overvol- tages with a DC voltage input. The operating value and the reset value Step 1. To set the detection method and type of input on the DIP switch. ...

Page 12

... Example 3 For the dual-function SDV-DH3, the setting method given below would be used to detect over and undervoltage with an AC voltage input. The intermediate voltage of dead band is 250 V and the dead band voltage Step 1. To set the detection method and type of input on the DIP switch. ...

Page 13

... Application Example Current Detection Using the Shunt (SDV-FL) Overload Detection (A) DC power SDV-SH supply for shunt distribution board (−) SDV-FL (with or without polarity) (+) Example: Overload detection in a distribution switch board installed in a power substation. Reverse Current Detection (A) SDV-SH DC power _ M shunt ...

Page 14

... Power supply Distribution board for general illumination Distribution board for emergency illumination SDV Detection of power failure or trans- former trouble (for the DC lighting command in emergency illumination) SDV-FH (undervoltage detection) Detection of battery overdischarge SDV-FH/SDV-FH@T with ON-delay operation (undervoltage detection) Detection of partial power failure (for the lighting ...

Page 15

... Voltage Monitoring in Rectifiers (Chargers) with ON-delay Operation Example: To detect only overvoltage and not detect voltages for instantaneous load changes (ON/OFF). Rectifier Note: Detection of excessive or insufficient charge in rectifiers (chargers). SDV-DH SDV-FH SDV-FH@T SDV-FM Control power supply SDV-FH@T SDV SDV-FH@T overvoltage detection SDV-FH@T undervoltage detection 15 ...

Page 16

... Q: Will the SDV be damaged if the input setting (AC/DC) is incorrect. If not, what will happen? A: The SDV will not be damaged, but the operating value and reset value will not be accurate. These values will be about 10% less than the set values input for an AC setting and about 10% off to the positive side input for a DC setting ...

Page 17

... Shunts SDV-SH5 to SDV-SH50 (60-mV Rating) 140 120 25 10.5 dia 5.5 dia. Current terminal: M6 screw Voltage terminal: M4 screw Model A B SDV-SH75 140 120 SDV-SH100 140 120 SDV-SH150 140 120 SDV-SH200 140 120 5 7 8.5 89 100 8.5 100 SDV-SH75 to SDV-SH200 (60-mV Rating) ...

Page 18

... SDV-SH300/-SH500 (60-mV Rating Current terminal: M10 screw (SDV-SH300), M12 screw (SDV-SH500) Voltage terminal: M4 screw Model SDV- 130 30 110 4 SH300 SDV- 160 40 120 6 SH500 Note: Inquire about models with a rated current of 1,500 A or larger. ■ Accessories (Order Separately) Front Connecting Socket 8PFA1 Eight, M3 ...

Page 19

... Spacers PFP-S 10 6.2 1.8 1 35.5 35.3 1.8 1.3 4.8 Mounting Holes Two, 3.5-dia. or two, M3 socket mounting holes 31-dia. hole Terminal Arrangement (Bottom View) Mounting Holes Two two, 3.5-dia. voltage sensor mounting holes 42-dia. hole 16 35+0 34.8 44.3 16.5 SDV 19 ...

Page 20

... each 7 circuit Power supply 8 circuit Note: 1. There is no power supply polarity setting when using a DC control power supply for the SDV. 2. There is no polarity setting for DC inputs. SW1 Overvoltage/ 2 Undervoltage selector switch Chopper Power SW1 supply circuit 1 2 Power supply Output relay ...

Page 21

... Do not mount the SDV until the Socket has been mounted firmly. Be sure that the key groove on the Socket is mounted on the bottom, and also secure the SDV to the panel with screws. When mounting with the 8PFA or 14PFA Back Connection Socket, insert the SDV into the Socket and secure it with the hooks ...

Page 22

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...